4.10
PERFORMANCE MONITOR SETTING
When the following units are replaced, adjust the performance monitor according
to the procedures shown in this section.
•
Performance monitor
•
Scanner unit
[I] Receiving monitor adjustment (MON Adjustment)
Make adjustments of the circuit that monitors the reception performance of the
radar apparatus.
Procedures
1)
When the radar apparatus has an inter-switch function, make settings for a
master display unit.
2)
Open the [Service Man Menu] screen.
3)
Open the [4.MON Adjustment] screen according to the operation shown below.
4)
Increase or decrease the adjustment value so that the farthest end of the
MON pattern is 18.0 nm.
Fig 4-4:
MON adjustment
1. Adjust Menu
→
4. TXRX Adjustment
→
4. MON Adjustment
MON pattern
Increase or decrease the
adjustment value so that the
farthest end of the MON
pattern is 18.0 nm