MODELS -           290-AH1             AMP HOUR TOTALIZER 
                              290-AHP2  STROKECOUNT PUMP CONTROLLER 
                                        (Models: P2-1/1, 1/2, 2/1, 2/2) 
CONTENTS: 

 

1.            GENERAL INFORMATION FOR AMP-HOUR BASED METERS  P.2 
2.            MODEL 290-AH1 MENU OPERATION                         P.3 
              

A.           AH TOTAL DISPLAY                                       P.3 

               B.           RESETTABLE DISPLAY                                 P.3 

3.            MODEL 290-AHP2 MENU OPERATION                      P.3-6 

               A.           AH TOTAL DISPLAY                                        P.3 
               B.           RESETTABLE DISPLAY                                  P.3 
               C.           MANUAL                                                           P.3 
               D.           PRESET1 &2 DISPLAY                                    P.4 
               E.           PRESET1 &2  CNT LEFT DISPLAY                P.4 
               F.           STROKE 1 &2 DISPLAY                                  P.4 
               G.           STROKE 1 &2 CNT LEFT DISPLAY               P.4 
               H.           CYCLE COUNT 1 &2 DISPLAY                      P.4 
               I.             SETUP DISPLAY                                              P.4 
                              1.            SHUNT SIZE 1 & 2 DISPLAY           P.5 
                              2.            RELAY1 & 2 DISPLAY                      P.5 
                              3.            RELAY 3 DISPLAY                           P.5 
                              4.            LOW LEVEL ALARM                         P.5 
                              5.            HIGH LEVEL ALARM                        P.5 
                              6.            STROKE TIMER                                P.6 
                              7.            MANUAL                                            P.6 
                              8.            SPECIAL FUNCTIONS                     P.6 
                                             a.            COUNTLINK                       P.6 
                                             b.            NETWORK                          P.6 

4.            APPENDIX                                                                        P. 7-9 
              

A.  CALCULATING THE PRESET AND TIMER VALUES   

               B.  PUMP SETTING WORKSHEET 

5.

INSTALLATION DIAGRAM                                                    P. 10-11 

6.

TROUBLE-SHOOTING                                                          P. 12

 

7.

WARRANTY, TERMS OF SALE                                           P.13

 

CHECK FOR FREE MANUAL UPDATES AT 

www.jptech.com

 

 

JP Tech, Inc. 

 Box 863 

 2286 Church Street, Unit C

 East Troy 

 WI 

 53120 

Phone (262) 642-7671 

 Fax (262) 642-7681 

Rev 12/09/12 

Summary of Contents for 290-AH1

Page 1: ...4 G STROKE 1 2 CNT LEFT DISPLAY P 4 H CYCLE COUNT 1 2 DISPLAY P 4 I SETUP DISPLAY P 4 1 SHUNT SIZE 1 2 DISPLAY P 5 2 RELAY1 2 DISPLAY P 5 3 RELAY 3 DISPLAY P 5 4 LOW LEVEL ALARM P 5 5 HIGH LEVEL ALARM...

Page 2: ...until the LEFT MOST DIGIT begins to flash When it flashes release the SELECT key If you want the digit that is flashing to stay the same PRESS and RELEASE the SELECT key ONCE This will move the flashi...

Page 3: ...This model incorporates everything the Model 290 AH1 has plus it can support 2 pumps with associated Presets and Stroke Counters and 1 Alarm output All internal output relays are fused Also the statu...

Page 4: ...alues that is the desired number of strokes each time the pump runs The STROKE2 screen operates the same way for Relay2 Programming See GENERAL INFORMATION STROKE1 000000 LmV G To the right is the STR...

Page 5: ...60mV and 100 mV SHUNT SIZE 2 operates the same way for those models that support two rectifiers Set SHUNT SIZE 2 to the rated amperage size of the second rectifier Disregard SHUNT SIZE 2 if your mode...

Page 6: ...ll be activated again Programming See GENERAL INFORMATION STROKE TIMER 00 DISABLED 7 To the right is the MANUAL display This display DISABLES or ENABLES the manual over ride pump con trol function Onc...

Page 7: ...amp hour count X 6000 amp shunt 1260 ml per 6000 amp hours Step 4 Determine actual pump flow rate The flow rate should be calculated for one minute Use a measured container to gather this information...

Page 8: ...own 6000 2376 Difference 0 0 Error 0 0 Dividing by 10 Ratio 600 0 amp hours 237 6 Seconds Round Down 600 0 237 Difference 0 0 6 Seconds Error 0 0 25 Dividing by 10 Ratio 60 00 amp hours 23 76 Seconds...

Page 9: ..._________ml 1 Amp Hour C B C B Step 3 Desired Feed Rate __________ml per 1 Amp Hour X E _________Amps F _________ml Hour D Shunt Size D X E Step 4 Measure Actual Pump Rate Per Minute G __________ml pe...

Page 10: ...10...

Page 11: ...11...

Page 12: ...T ENGAGE WHEN TIMER TIMES OUT OR WHEN ACTIVATED IN PRIME PUMP SCREEN May have blown the 5A fuse protecting the relays Open lid of controller and check the fuse for conti nuity Unplug unit while doing...

Page 13: ...ment be subrogated to exclusive distributors or manufacturers who shall assume all or portions of the liability associated with warranty costs This warranty may be modified wholly or in part at any ti...

Reviews: