21
ENGLISH
Min
Max
*Total thermal power (efficiency)
2,9 kW
7 kW
Efficiency
92,3 %
89 %
Smoke temperature
85,8 °C
193,7 °C
Smoke flowrate
3,47 g/s
4,6 g/s
Hourly consumption
0,628 kg/h
1,6 kg/h
CO emissions (13% O2)
151 mg/Nm
3
25,9 mg/Nm
3
Smoke extraction
Ø 8 cm
Air inlet
Ø 6 cm
Weight
116 kg
Fuel
Pellets
Feed container capacity
17 kg
Draught
12(±2) Pa
To calculate the chimney flue’s dimensions, use:
0.0 Pa
Furnace advised for volumes no smaller than
30 m
3
TECHNICAL DATA
Jøtul PF 732
(according to standard EN 14785)
ELECTRICAL STANDARDS
Voltage
230 V
Frequency
50 Hz
Maximum power consumption during work
80 W
Elektryczny zapłon
380 W
Summary of Contents for PF 732
Page 23: ...23 ENGLISH DIMENSIONS Jøtul PF 732 475 593 67 1096 Ø83 1100 469 547 469 370 Ø60 549 ...
Page 25: ...25 ENGLISH ...
Page 47: ...47 ITALIANO DIMENSIONI Jøtul PF 732 475 593 67 1096 Ø83 1100 469 547 469 370 Ø60 549 ...
Page 49: ...49 ITALIANO ...
Page 71: ...71 POLSKI WYMIARY Jøtul PF 732 475 593 67 1096 Ø83 1100 469 547 469 370 Ø60 549 ...
Page 73: ...73 POLSKI ...
Page 74: ...74 POLSKI ...