2.0 Technical data
Material:
Cast iron
Finish:
Black Paint
Type of fuel:
Wood
Max. log length:
50 cm
Smoke outlet:
Top or rear-installed smoke
outlet (rotated 45°).
Flue pipe dimension:
Ø 150 mm
Weight:
Approx. 110 kg
Optional extras:
Leg Rack complete, door
lock complete - left, frames,
sheet metal grids, and
convection top plate.
Product dimensions, distances: See
fi
g. 1
Technical data in accordance with EN
13229
Nominal heat output:
7 kW
E
ffi
ciency:
77%
CO emissions (13% O2):
0.07%
CO emissions (13% O2):
884 mg/Nm3
OGC emissions (13% O2):
60 mg/Nm3
Dust emissions (13% O2):
14 mg/Nm3
Flue gas temperature:
305°C
Flue gas
fl
ow rate:
7,1 g/s
Chimney draught, EN 13229: 12 Pa
Recommended draught
with smoke outlet:
16-18 Pa
Fuel consumption:
2.3 kg/h
Kindling quantity:
1,7 kg
Max. kindling:
3,4 kg each time and 3,8 kg/h
Operation: Intermittent
“Intermittent combustion” here means normal use
of a stove. That is to say, if you want to continue
producing heat, you add more fuel as soon as the
previous load of wood has burnt down to embers.
On all our products there is a
label indicating the serial number
and year. Write this number in the
place indicated in the installation
instructions.
Always quote this serial number
when contacting your retailer or
Jøtul.
les combustibles recommandés.
Respectez les consignes d'utilisation. Utilisez uniquement
Verwenden Sie nur empfohlenen Brennstoffen.
Montage- und Bedienungsanleitung beachten.
Follow user`s instructions. Use only recommended fuels.
standard
Certificate/
The appliance can be used in a shared flue.
Minimum distance to adjacent combustible materials:
Emission of CO in combustion products
Lot no: Y-xxxx, Year: 200x
Manufacturer:
N-1602 Fredrikstad
Norway
Jøtul AS
POB 1441
Sweden
EUR
Intermittent
Nominal heat output
Norway
Country
Operational type
Fuel type
Operation range
Efficiency
Klasse II
Classification
Standard
Flue gas temperature
Room heater fired by solid fuel
Product:
Jøtul
SP Sveriges Provnings- och
221546
Forskningsinstitut AB
SP Swedish National
Testing and Research
Institute
:
Approved by
:
:
:
:
:
:
:
Minimum distance to adjacent combustible materials:
OGC
SP
EN
Lot no. Pin.
Table of contents
Installation manual with technical data
1.0 Regulatory information ........................... 3
2.0 Technical data ......................................... 3
3.0 Safety
....................................................... 4
4.0 Installation .............................................. 4
5.0 Daily use ................................................ 28
6.0 Maintenance
.......................................... 30
7.0 Servicing ................................................ 31
8.0 Optional Extras ..................................... 33
9.0 Operational problems -
troubleshooting
..................................... 34
9.0 Recycling
............................................... 34
10.0 Guarantee terms
.................................... 34
ENGLISH
Register your
fi
replace at jotul.com for a
25-year warranty.
Summary of Contents for i 520
Page 25: ...25 ENGLISH B min 505 mm min 13 mm max 35 mm adjustable min 650 mm min 540 mm...
Page 56: ...56 B min 520 mm min 13 mm max 35 mm verstelbar min 660 mm min 540 mm NEDERLANDS...
Page 87: ...87 B min 520 mm min 13 mm max 35 mm Einstellbar min 660 mm min 540 mm DEUTSCH...
Page 98: ...98 BELGI...