authorities

Installation of a fireplace must be according to local codes and 

regulations in each country. All local regulations, including those 

that refer to national and European standards, shall be complied 

with when installing the product.

Instructions for mounting, installation and use are enclosed with 

the product. Prior to using the product the installation must be 

approved by a qualified person. 

A product data plate in heat resistant material is located on the 

heat shield under the product. This contains information about 

identification and documentation for the product. 

2.0 Technical data

Material:  

Cast iron

Finish:  

Black paint, blue black enamel

Fuel:  

Wood

Log length, max:  

40 cm

Flue outlet:  

Top, rear 

Flue pipe dimension: 

Ø125 mm/123 cm

2

 cross section

Weight:  

78 kg

Product measures: 

See 

fig. 

1

Technical data according to EN 13240

Nominal heat output: 

6,0 kW

Flue gas mass flow: 

6,9 g/sec

Recommended chimney draught: 

12 Pa

Efficiency: 

71% @ 6,1 kW%

CO emission (

13

% O

2

): 

0,28%

Flue gas temperature: 

318

o

 C

Operational type: 

Intermittent

Intermittent combustion is here taken to mean normal use of a 

fireplace. I.e. that a new flame chamber is lit as soon as the fuel 

has burnt down to the appropriate quantity of embers.

Wood  consumption

Jøtul  F 

602 

has  a  nominal  heat  output  of 

6,0

  kW.  Use  of 

wood, with nominal heat emission: Approx. 

2,0 kg/h

. Another 

important  factor  for  proper  fuel  consumption  is  that  the 

logs  are  the  correct  size. The  size  of  the  logs  should  be:

Kindling:

Length: 30 - 40 cm

Diameter: 2 - 5 cm

Amount per fire: 8 - 10 pieces

Firewood (split logs):

Length: 40 cm

Diameter: Approx. 8 - 12 cm

Intervals for adding wood: Approx. every 45 minutes

Size of the fire:  1,5 kg

Amount per load:  2 pieces.

Nominal heat emission is achieved  when the air vent is open 

approximately 50%.

Table of contents 

Installation manual with technical data

1.0   Relationship to the authorities ................... 13

2.0  Technical data ............................................... 13

3.0  Installation  ..................................................14

4.0  Service ........................................................... 15

5.0  Optional Equipment .................................... 15

Figures ................................................................... 28

Table of contents 

General use and maintenance manual

6.0  Safety precautions

7.0 

Choice of fuel 

8.0 

Use

9.0  Maintenance

10.0   Operational problems - troubleshooting

On all our products there is a label 

indicating the serial number and year. 

Write this number in the place indicated 

in the installation instructions. 

Always quote this serial number when 

contacting your retailer or Jøtul.

les combustibles recommandés.

Respectez les consignes d'utilisation. Utilisez uniquement

Verwenden Sie nur empfohlenen Brennstoffen.

Montage- und Bedienungsanleitung beachten. 

Follow user`s instructions. Use only recommended fuels.

standard

Certificate/

The appliance can be used in a shared flue.

Minimum distance to adjacent combustible materials:

Emission of CO in combustion products

Serial no: Y-xxxx, Year: 200x

Manufacturer:

N-1602 Fredrikstad
Norway

Jøtul AS
POB 1441

Sweden

EUR

Intermittent

Nominal heat output      

Norway

Country

Operational type

Fuel type

Operation range

Efficiency

Klasse II

Classification

Standard

Flue gas temperature             

Room heater fired by solid fuel

Product:

Jøtul

SP Sveriges Provnings- och

221546

Forskningsinstitut AB
SP Swedish National 
Testing and Research
Institute

:

Approved by

:

:

:
:

:
:

:

Minimum distance to adjacent combustible materials:

OGC 

SP 

EN 

Serial no.

eNgliSh

For more information on Jøtul visit www.barbourproductsearch.info

Reviews: