3
ENGLISH
1.0 Relationship to the
authorities
Installation of a
fi
replace must be in accordance with local
codes and regulations in each country.
All local regulations, including those which refer to national
and European standards, must be observed when installing
the product.
The installation can only be put into use after it has been
checked by a quali
fi
ed inspector. Contact your local building
authorities before installing a new
fi
replace.
A product approval plate of heat-resistant material is to
be found in the ash pan. This contains information about
identi
fi
cation and documentation for the product.
2.0 Technical data
Materiale
Cast iron
Finish
Black paint
Fuel
Wood
Max, Log length
55 cm
Recommended log length
30-55 cm
Flue outlet
Top, rear
Flue pipe dimension
Ø 150 mm
Outside air connection
Alu.
fl
ex - Ø 100 mm
Approx. weight for Jøtul F 500 ECO IT
ca 200 kg
Optional extras
Heat shield rear,
External air kit, Soapstone
top cover.
Dimensions, distances
See
fi
g. 1
Technical data in acc. with EN 13240
Nominal heat output
10,5 kW
Flue gas volume
7,4 g/s
Chimney draught, EN 13240
12 Pa
Recommended negative pressure in
smoke outlet
12-15 Pa
E
ffi
ciency
86%@10,5 kW
CO emissions (13% O
2
)
0,08 %
CO emissions (13% O
2
)
990 mg / Nm
3
NOx (13% O
2
)
99 mg / Nm
3
OGC (13 % O
2
)
67 mg C /Nm
3
Air consumption
6,2 liter/sec.
Chimney temperature, EN 13240
211
0
C
Dust (13% O
2
)
6 mg/Nm
3
@13%O
2
Fuel consumption
2,83 kg/h
Max. kindling amount
5,21 kg
Nominal kindling amount
2,08 kg
Operation
Intermittent*
*Intermittent combustion in this context means normal use of
the
fi
replace, i.e. fuel is added as soon as the fuel has burnt
down to a suitable amount of embers.
Register your
fi
replace at jotul.com for a
25-year warranty.
les combustibles recommandés.
Respectez les consignes d'utilisation. Utilisez uniquement
Verwenden Sie nur empfohlenen Brennstoffen.
Montage- und Bedienungsanleitung beachten.
Follow user`s instructions. Use only recommended fuels.
standard
Certificate/
The appliance can be used in a shared flue.
Minimum distance to adjacent combustible materials:
Emission of CO in combustion products
Lot no: Y-xxxx, Year: 200x
Manufacturer:
N-1602 Fredrikstad
Norway
Jøtul AS
POB 1441
Sweden
EUR
Intermittent
Nominal heat output
Norway
Country
Operational type
Fuel type
Operation range
Efficiency
Klasse II
Classification
Standard
Flue gas temperature
Room heater fired by solid fuel
Product:
Jøtul
SP Sveriges Provnings- och
221546
Forskningsinstitut AB
SP Swedish National
Testing and Research
Institute
:
Approved by
:
:
:
:
:
:
:
Minimum distance to adjacent combustible materials:
OGC
SP
EN
Lot no. Pin.
On all our products there is a label
indicating the serial number and
year. Write this number in the
place indicated in the installation
instructions.
Always quote this serial number
when contacting your retailer or
Jøtul.
Table of contents
1.0 Relationship to the authorities
3
2.0
Technical
data
3
3.0
Safety
4
4.0
Installation 6
5.0
Daily
use
9
6.0
Maintenance
12
7.0
Service
13
8.0 Operational problems -
troubleshooting
16
9.0 Optional equipment
16
10.0
Recycling
16
11.0 Guarantee terms
16
UK - Installation and
operating instructions