9
Installation manual with technical data
1.0
Relationship to the authorities ................... 9
2.0
Technical data .............................................. 9
3.0 Installation
..................................................10
4.0 Service
...........................................................11
5.0
Optional equipment ...................................11
Figures/ Pictures ..................................................32
General use and maintenance manual
6.0
Safety
precautions
7.0
Choice of fuel
8.0
Use
9.0
Maintenance
10.0 Operational problems - troubleshooting
les combustibles recommandés.
Respectez les consignes d'utilisation. Utilisez uniquement
Verwenden Sie nur empfohlenen Brennstoffen.
Montage- und Bedienungsanleitung beachten.
Follow user`s instructions. Use only recommended fuels.
standard
Certificate/
The appliance can be used in a shared flue.
Minimum distance to adjacent combustible materials:
Emission of CO in combustion products
Serial no: Y-xxxx, Year: 200x
Manufacturer:
N-1602 Fredrikstad
Norway
Jøtul AS
POB 1441
Sweden
EUR
Intermittent
Nominal heat output
Norway
Country
Operational type
Fuel type
Operation range
Efficiency
Klasse II
Classification
Standard
Flue gas temperature
Room heater fired by solid fuel
Product:
Jøtul
SP Sveriges Provnings- och
221546
Forskningsinstitut AB
SP Swedish National
Testing and Research
Institute
:
Approved by
:
:
:
:
:
:
:
Minimum distance to adjacent combustible materials:
OGC
SP
EN
Serial no.
On all our products there is a label
indicating the serial number and year.
Write this number in the place indicated
in the installation instructions.
Always quote this serial number when
contacting your retailer or Jøtul.
ENGLISH
1.0 Relationship to the
authorities
Installation of a fireplace must be according to local codes and
regulations in each country.
All local regulations, including
those which refer to national and European standards, must be
observed when installing the product.
Both an installation manual with technical data and a manual
on general use and maintenance are enclosed with the product.
The installation can only be used after it has been inspected by
a qualified inspector.
A name plate of heat-resistant material is affixed to the
product. This contains information about identification and
documentation for the product.
2.0 Technical data
Material: Cast
iron
Material sideplates:
Cast iron or
soapstone (optional equipment)
Finish: Paint
Fuel: Wood
Log length, max.:
35 cm
Flue outlet:
Top and rear
Flue pipe dimension:
Ø150 mm, 177 cm
2
cross section
Approx. weight:
Stove: 170 kg,
Set of soapstone: 54 kg
Optional extras:
Side plates in soapstone,
Top tile insoapstone, extra rear
heat shield
Dimensions, distances:
See
fig.1
Technical data according to EN 13240
Nominal heat output:
8,0 kW
Flue gas mass flow:
9,0 g/s
Recommended chimney draught:
12 Pa
Efficiency: 75%@8,2
kW
CO emission (13% O
2
): 0,08%
Flue gas temperature:
340
o
C
Operational type:
Intermittent
“Intermittent combustion” here means normal use of a stove.
That is to say, if you want to continue producing heat, you add
more fuel as soon as the previous load of wood has burnt down
to embers.
Wood consumption
Jøtul F
350
has a nominal heat output of
8,0
kW.
Use of wood,
with nominal heat emission: Approx.
1,8 kg/h
. Another important
factor for proper fuel consumption is that the logs are the correct
size.
The size of the logs should be:
Kindling:
Length: 30 cm
Diameter: 2 - 5 cm
Amount per fire: 6 - 8 pieces
Firewood (split logs):
Length: Approx 30 cm
Diameter: Approx. 8 cm
Intervals for adding wood: Approximately every 45 minutes
Size of the fire: 2,0 kg
Amount per load: 3 pieces
Nominal heat emission is achieved when the ignition vent is
open approximately 50% and the air vent 20-25%.