14
ENGLISH
Table of contents
1.0 Relationship to the authorities ...................... 14
2.0 Technical data ................................................ 14
3.0 Safety precautions ......................................... 15
4.0 Installation ..................................................... 15
5.0 Use ..................................................................16
6.0 Maintenance .................................................. 18
7.0 Service .............................................................19
8.0 Optional Equipment and Accessories ...........19
9.0 Operational problems - troubleshooting .....19
Figures ................................................................. 50
1.0
Relationship to the
authorities
Installation of a fireplace must be according to local codes and
regulations in each country.
All local regulations, including those that refer to national and
European standards, shall be complied with when installing the
product.
Instructions for mounting, installation and use are enclosed with
the product. Prior to using the product the installation must be
inspected by a qualified person.
A product data label in heat resistant material can be found on the
heat shield underneath the product. This contains information
about identification and documentation for the product.
2.0
Technical data
Material:
Cast iron
Finish:
Black paint
Fuel:
Wood
Log length, max:
40 cm
Flue outlet:
Top, rear
Flue pipe dimension:
Ø 175 mm, 240 cm
2
cross section
Approx. weight:
106 kg
Optional extras:
Decorative enamelled floor
plate in blue black - Rear heat
shield, short legs* (see
8.0
)
Dimensions, distances:
See
fig. 1
Technical data according to EN 13240
Nominal heat output:
6,5 kW
Flue gas mass flow:
4,8 g/sec
Recommended chimney draught: 12 Pa
Efficiency: 79%@7,4kW
CO emission (13% O
2
): 0,30%
Flue gas temperature:
330
o
C
Operational type:
Intermittent