jotron.com
Page 34 of 52
5.5.4.4
Maximum number of extended self-tests exceeded
The extended self-test uses much current and is therefore limited in
number. The Beacon will continue to operate as normal in emergency
mode and you can still perform normal self-test.
However, verification of the GNSS is not possible until the battery is
replaced. Contact a service partner for replacing of the battery.
5.5.4.5
Other faults
Something is wrong with the configuration of the Beacon. Contact a dealer
or service partner immediately.
THE BEACON WILL NOT WORK PROPERLY UNTIL THIS ERROR IS FIXED
5.5.5
Testing of the AIS locating signal
During standard self-test mode, the EPIRB will transmit two text messages
with the 15HEX ID in one message and the text EPIRB TEST in the other
message.
When doing GNSS self-test the position messages are also output together
with the text messages.
Normally AIS stations will suppress AIS SART test messages but can be
placed in a mode that will display the test information. If an AIS installation
is going to be used to verify AIS SART test messages, please consult the
equipment manual of the AIS system for more information about this.
If an AIS station is used to verify the test mode, it must enter a special
mandatory mode. Consult the instruction manual for the AIS installation for
more information about this.
5.6
Deactivation of the EPIRB
If the EPIRB has been accidentally activated or to deactivate it after use,
remove it from the water and move the switch back to its middle position.
Note that it can take up to 15 seconds before the top flash stops blinking.