background image

26

induction heating

Induction heater JH1500

Maintenance interval

Once a month:

• 

Check the cooling water

• 

Check the residual current breaker

• 

Check the hose couplings

• 

Check connection surface between heating 
tip and handheld transformer

Once a year or when needed:

• 

Check and clean the condenser

• 

Check the cable connections 

Maintenance description

Check the cooling water

MAINTENANCE INSTRUCTIONS

Note!

 Do not mix different types 

of glycol in the cooling water.  
This would make the freezing 
point impossible to control.

Check that the cooling water tank is filled to at 
least 80% with cooling water. Note, for more 
powerful heating (>15 min/occasion), the 
cooling water level should be higher (80‑90%).

To refill the cooling water use 

decalcified 

water and propylene glycol

.

Check the residual current breaker

Check the residual current breaker once a 
month, by pressing the test button (T). After the 
test button is pressed in, the residual current 
breaker must trigger. If this does not happen, 
the residual current breaker must be replaced 
before the machine is used again.

Summary of Contents for JH1500

Page 1: ...T 152 1 1309 15236 Instructions for use and safety regulations for Induction heater JH1500...

Page 2: ...is used for heating metal parts on vehicles without damaging nearby parts All other use of the equipment or use that does not comply with the instructions in this instruction book can cause personal i...

Page 3: ...3 induction heating Induction heater JH1500 CE CERTIFICATE...

Page 4: ...fuse 18 USB connection 18 Control panel 19 Alarm indicators 20 Operation indicator 20 Hose packet 21 Connection block 21 Handheld transformer with hose kit 21 Trigger button 21 Inductor 22 Usage 23 Ge...

Page 5: ...in place and places that are difficult to reach Heating screws that have rusted in place Nuts on the suspension or the steering Simple removal of underbody protection and PVC coating Frame straighten...

Page 6: ...6 induction heating Induction heater JH1500 Marking The identification plate is located on the back of the JH1500 400 V 200 V...

Page 7: ...ed as an excuse to ignore one s own personal responsibility or applicable regulations Great care has been taken during the design and manufacture of the JH1500 to ensure the system conforms with the a...

Page 8: ...important information can be found in the operating instructions WARNING Do not place the induction heater on unlevel or instable surfaces The induction heater can fall over and cause personal injury...

Page 9: ...ys etc The objects can be heated up by the magnetic field from the JH1500 and cause burn injuries WARNING Most of the servicing must be performed by service personnel or service support from JOSAM AB...

Page 10: ...safety goggles when you use the equipment WARNING Sparks from the induction heater can cause fires WARNING Danger of tripping over loose hoses etc WARNING Always read the user instructions before usin...

Page 11: ...late when the machine is started A sensor detects the water flow and trips the induction heater if the flow is blocked The JH1500 must be connected to earth It has an inbuilt residual current breaker...

Page 12: ...nstalled in accordance with the instructions in this instruction book It is also the owner s responsibility to ensure that the equipment is inspected according to applicable regulations before it is u...

Page 13: ...ould be filled to between 80 90 WARNING Do not fill the water tank with anything other than decalcified water mixed with propylene glycol Incorrect handling can cause personal harm and or damage to eq...

Page 14: ...rrent must be earthed and it must also be protected by a fuse according to the following The electric supply must be protected by a 32 A 400 V or 63 A 200 V fuse when using maximum power step 5 The JH...

Page 15: ...ce intense heat is created in the work piece and inductor cooling water is used for cooling the machine and its electronic parts The control of the cooling system is totally automatic The connection c...

Page 16: ...16 induction heating Induction heater JH1500 Cooler section The cooler section consists of a 1 cooling water tank 2 water pump 3 connection box 4 condenser 5 condenser fan DESCRIPTION 1 2 5 3 5 4...

Page 17: ...ions namely supplying current to the hose packet electronic components and the cooling section The electrical section comprises 1 control panel 2 main power switch 3 residual current breaker 4 main fu...

Page 18: ...an earth fault There is a test button on the residual current breaker When the test button is pressed the residual current breaker should trip Main fuse 32 A 400 V or 63 A 200 V The main fuse trips i...

Page 19: ...Off To use the induction heater after it has been connected to the electric mains you must press the On Off button When you have pressed the button one or more of the yellow LEDs lights up on the pow...

Page 20: ...ressure is too low The induction heater does not function when this indicator is lit General electronic alarm If both LEDs are blinking at the same time the cause is often that one of the phases is mi...

Page 21: ...in the connection block and further through the hose up to the handheld transformer Handheld transformer with hose kit During use the handheld transformer functions as a tool handle the control button...

Page 22: ...eater JH1500 Inductor During use the inductor is supplied with a voltage and an alternating magnetic field is generated by the field power amplifier at the inductor s tip The cooling water circulates...

Page 23: ...s important to control the temperature of the heated work piece if quality is to be maintained The human eye is influenced by the ambient conditions The illumination changes how the eye experiences co...

Page 24: ...e that there is good ventilation so as to avoid breathing in the gases that are formed during heating Warning The work area must be free from flammable objects Risk of fire Heating Warning Do not touc...

Page 25: ...1 Turn off at the main power switch 2 Wrap the hose packet around the big handle on the machine and place the inductor in the holder 3 Wrap the power cable around the small handle on the machine Note...

Page 26: ...f glycol in the cooling water This would make the freezing point impossible to control Check that the cooling water tank is filled to at least 80 with cooling water Note for more powerful heating 15 m...

Page 27: ...ble glands if necessary To be checked once a year Fitting the inductor Before use the inductor must be attached to the handheld transformer The inductor is screwed in place with four stainless steel s...

Page 28: ...protective covers and never perform any work on the induction heater without first removing the contact from the wall socket Wait one minute Danger of electrical shocks WARNING Remove the induction h...

Page 29: ...nt but the induction heater doesn t work The residual current breaker has triggered Identify the cause of the error and take the appropriate action Then reset the residual current breaker Water leak b...

Page 30: ...is giving the wrong value Check for stuck paddle in water flow sensor or replace water flow sensor The operation LED is blinking fast at start up The heating button is being pressed when starting the...

Page 31: ...rkshop environment for repairing vehicular damages Warranty If the instructions in this manual are not followed the machine s warranty becomes null and void Recycling The machine must be recycled acco...

Page 32: ...75 kg Input power requirement 15 kW Degree of protection IP 21 Coolant Water propylene glycol Water tank volume 40 litres Installation electric mains connection Mains connection 3 380 400 V PE 32 A or...

Reviews: