26
induction heating
Induction heater JH1500
Maintenance interval
Once a month:
•
Check the cooling water
•
Check the residual current breaker
•
Check the hose couplings
•
Check connection surface between heating
tip and handheld transformer
Once a year or when needed:
•
Check and clean the condenser
•
Check the cable connections
Maintenance description
Check the cooling water
MAINTENANCE INSTRUCTIONS
Note!
Do not mix different types
of glycol in the cooling water.
This would make the freezing
point impossible to control.
Check that the cooling water tank is filled to at
least 80% with cooling water. Note, for more
powerful heating (>15 min/occasion), the
cooling water level should be higher (80‑90%).
To refill the cooling water use
decalcified
water and propylene glycol
.
Check the residual current breaker
Check the residual current breaker once a
month, by pressing the test button (T). After the
test button is pressed in, the residual current
breaker must trigger. If this does not happen,
the residual current breaker must be replaced
before the machine is used again.