20
induction heating
Induction heater JH1500
Alarm indicators
The alarm indicators notify the user if a fault
occurs with the induction heater.
The alarm indicators are marked by a red LED.
Overheating
The red LED for overheating lights, if the
electronics become overheated. The induction
heater does not function if this indicator is
lit. The light goes out, when the temperature
drops below the warning limit.
Water flow
The red LED for the water flow lights, if the
cooling water is not flowing as it should, that is,
if the water pressure is too low. The induction
heater does not function when this indicator is
lit.
General electronic alarm
If both LEDs are blinking at the same time,
the cause is often that one of the phases is
missing in the wall outlet. This alarm indication
will also be shown if the machine is consuming
current even though it is in idle, or if a current
sensor is faulty.
Operation indicator / Trigger activated
The operation indicator provides the user with
information when the induction heater is in use.
The green LED begins to blink when the
trigger is pressed in. It indicates that the cable
to the handheld transformer isn't damaged,
that the water flow is functioning and that
correct power is reached in the inductor head.
DESCRIPTION