13
induction heating
Induction heater JH1500
Filling the water tank
The JH1500 is delivered with a filled water
tank, but if the tank needs to be filled manually
at some point, follow the instructions below.
Fill the water tank with a mixture of
decalcified
water and 30 % propylene glycol
.
1. Open the front cover.
2. Open the tank cap.
3. Fill the water tank (it should be filled to
between 80‑90%).
WARNING!
Do not fill the
water tank with anything other
than decalcified water mixed
with propylene glycol. Incorrect
handling can cause personal
harm and/or damage to
equipment.
NOTE!
Do not fill the tank
completely, since the water
expands as it heats up. Fill the
tank with 35 litres of fluid.
IMPORTANT!
Risk of
condensation in the JH1500.
Fill the water tank with room
tempered, not cold, water. If you
move the JH1500 from a cold
location, you should wait until
the water has warmed up to
room temperature before use.
INSTALLATION