Jordan Valve Mark 78 Series Installation And Maintenance Instructions Manual Download Page 1

3170 Wasson Road  •  Cincinnati, OH  45209  USA

Phone 513-533-5600  •  Fax 513-871-0105

[email protected]  •  www.jordanvalve.com

I & M Mark 78 Series 

Installation & Maintenance Instructions for 

Mark 78 Control Valves (1-1/2” - 2”)

Warning:

 Jordan Valve Control Valves must only be used, installed and repaired in accordance with these Installa-

tion & Maintenance Instructions. Observe all applicable public and company codes and regulations. In the event 
of leakage or other malfunction, call a qualified service person; continued operation may cause system failure or a 
general hazard. Before servicing any valve, disconnect, shut off, or bypass all pressurized fluid. Before disassembling 
a valve, be sure to release all spring tension.

Please read these instructions carefully!

Your Jordan Valve product will provide you with long, trou-
ble-free service if it is correctly installed and maintained.  
Spending a few minutes now reading these instructions 
can save hours of trouble and downtime later.  When mak-
ing repairs, use only genuine Jordan Valve parts, available 
for immediate shipment from the factory.

Ideal Installation

1.  To protect the valve from grit, scale, thread chips, and 

other foreign matter, all pipe lines and piping compo-
nents  should  be  blown  out  and  thoroughly  cleaned 
before the valve is installed.

2.  Shutoff  valves,  pressure  gauges,  and  bypass  piping 

should be installed as indicated in the diagram to pro-
vide easier adjustment, operation, and testing.

3.  In preparing threaded pipe connections, care should 

be  exercised  to  prevent  pipe  sealing  compound 
from  getting  into  the  pipe  lines.  Pipe  sealing  com-
pound should be used sparingly, leaving the two lead 
threads clean.

4.  A line strainer should be installed on the inlet side of 

the  regulator  to  protect  it  from  grit,  scale  and  other 
foreign matter. A 0.033 perforated screen is usually 
suitable.  Line  strainers  are  available  for  immediate 

shipment from Jordan Valve.

5.  Install the valve in the highest horizontal line of pip-

ing to provide drainage for inlet and outlet piping, to 
prevent water hammer and to obtain faster response.

6.  The flow arrow on the regulator body must be pointed 

in the direction of flow. The valve may be installed ver-
tically or horizontally without affecting its operation.

7.  For best control, 3’ 0” straight sections of pipe should 

be installed on either side of the valve.

8.  In hot vapor lines, upstream and downstream piping 

near the valve should be insulated to minimize con-
densation. 

9.  If possible, install a relief valve downstream from the 

valve. Set at 15 psi above the control point of the valve.

10. Expand the outlet piping at least one pipe size if the 

controlled pressure (downstream) is 25% of the inlet 
pressure or less. A standard tapered expander con-
nected to the outlet of the valve is recommended.

11.  Where surges are severe, a piping accumulator is rec-

ommended.

Start-Up

1.  Be sure that the action of the control valve and the 

controller are such as to give the desired results.  See 
“Reversing Action” to change the valve action if nec-
essary.

If an increase 

in pressure or 

temperature must:

And the 

action of the 

valve is:

Then the action 

of the controller 

must be:

Close Valve

Air to Close

Direct

Close Valve

Air to Open

Reverse

Open Valve

Air to Close

 Reverse

Open Valve

Air to Open

Direct

2.  The control valve has been pre-set by Jordan Valve.  

However, finer adjustments may be required to com-
pensate for pressure drop conditions of the applica-
tion.

3.  With the inlet, outlet and bypass shutoff valves closed, 

and no pressure in the downstream line, fully open the 
shutoff valve. Slowly open the inlet valve just enough 

Main Line

Control Valve

1.  Shut off Valve

2.  Pipe Union

3.  Strainer and Drain Valve

4.  Pressure Gauge

5.  Control Valve

6.  Relief Valve

Condensate Return

3

Bypass Line

1

1

6

R

4

1

2

5

2

1

4

Summary of Contents for Mark 78 Series

Page 1: ...0 033 perforated screen is usually suitable Line strainers are available for immediate shipment from Jordan Valve 5 Install the valve in the highest horizontal line of pip ing to provide drainage for...

Page 2: ...3 Lapping in Valve Plug Seat Ring replace valve plug 9 in bonnet 4 Apply superfine lapping compound to valve plug seating surface at several points Re place seat o ring 30 and seat 3 in body 1 Re asse...

Page 3: ...e valve If preload adjustment is made with no pressure in valve body then when the control valve is placed in operation body then when the control valve is placed in opera tion additional compression...

Page 4: ...shing 36 and gland nut 20 Place the springs 25 in the lower actuator case 16 Place the backing plate 39 85M actuator diaphragm plate 24 on the springs so that the stamped bosses are nested in the spri...

Page 5: ...by insufficient instrument output pres sure If You Experience Leakage or Erratic Regulation Excessive pressure drop reduce with pressure regu lating valve Plug may be binding There may be excessive fo...

Page 6: ...ctuator Case Assy 6 27 Hex Nut 1 28 Jam Nut 16 29 O Ring Body Bonnet 2 30 O Ring Seat 1 31 O Ring Actuator 1 32 Lock Ring 1 33 Yoke 1 34 Hex Bolt Actuator Stem 1 35 Travel Scale 1 36 Stem Bushing 1 37...

Page 7: ...4 34 38 39 21 31 36 17 24 20 19 18 40 16 27 43 26 7 27 23 16 18 31 36 17 20 19 21 22 24 38 34 25 27 7 23 26 40 34 21 22 38 39 25 4 24 43 31 36 17 20 19 15 16 26 24 22 34 21 38 43 31 36 17 20 19 18 25...