8
CLEANING INSTRUCTIONS
7. Reassemble the valve inner parts and
screw the valve back in to the bottom part
of the housing using a 23 mm wrench (Max.
torque 10Nm).
WARNING: The electronics compartment is
connected to the bottom part with a cable! Do not
damage this cable!
8. Close the housing by replacing the electronics
compartment and top part on the reservoir and
fixing the 4 housing bolts. (Max. Torque 6Nm).
Make sure the gaskets are secured properly to
ensure IP65 rating and make sure the electronics
have not been in contact with water.
WARNING: Please make sure the cable connected to
the electronics part does not get damaged while
re-assembling the components!
9. Switch on the electrical supply by
replacing the connector and connector
screw (max. torque 1Nm). Make sure the
gasket is secured properly to ensure IP65
rating.
Make sure the display lights up to check if the
power supply is successfully connected.
10. Slowly open the ball valve to restore normal
system pressure.
11. Press and hold down the TEST button
to check the valve function.
12. Your KAPTIV-CS-HP-S is ready for
operation!