Jolly D5-BS User Manual Download Page 1

USER MANUAL

Version:1.0

Summary of Contents for D5-BS

Page 1: ...USER MANUAL Version 1 0 ...

Page 2: ......

Page 3: ... equipment specification 16 10 1 Electrical paramters 16 10 2 10 3 4 2Installing the Clamps 4 4 3 Power supply connection and cut off 5 4 4 Power Connection 6 4 5 DMX 512 connection connection between fixtures 6 17 Channel Characteristics 17 10 4 Menu Function 17 11 Electronic drawing 18 Description of the device 7 Dimension 8 Display control 9 Navigation in the Menu 9 Display Operation 9 Menu lis...

Page 4: ...lly read this instruction manual in its entirety and keep it well for using reference This manual contained about the installation and the relative using information of this products Plese refere this manual s relative instruction when using this equipment ...

Page 5: ...he safety instruc notes written in this manual Important The manufacturer will not accept liability for any resulting damages caused by the nonobservance of this manual or any unauthorized modification to the device Please consider that damages caused by manual modifications to the device are not subject to warranty condition and to ti ons and warning Every person involvd with installation and mai...

Page 6: ...rojector Maximum ambient temperature Do not operate the fixture if the ambient temperatuer Ta exceeds 40 C 104 F Temperature of the external surface The maximum temperature that can be reached on the external surface of the fitting in a ther mally steadystate is 90 C 194 F IP20 protection rating The fitting is protected against penetration by solid of over 12mm 0 47 in diameter first digit 2 but n...

Page 7: ... around You endanger your own and the safety of others The minimum distance between light output and the illuminated surface must be more than 0 2 meters Make sure that the area below the installation place is blocked when rigging derigging or servicing the fi xture Always fix the fixture with an appropriate safety rope Fix the safety rope at the correct holes only Operate the fixture after having...

Page 8: ... first time and after changes before taking into operation an other time The operator has to make sure that safety relating and machine technical installations are approved by an expert after every four year in the course of an acceptance test The operator has to make sure that safety relating and machine technical installations are approved by a skilled person once a year The projector should be ...

Page 9: ...ng system etc 1 2 3 4 mounting plate secure chain omega holder Lock catch 4 3 Power supply connection and cut off Connect the light source to the main power source with the plug of the power cord or cut off the power supply Connection according to procedures the power plug and socket is inserted into the groove one one alignment rotation Cut off according to procedures press the button on the rota...

Page 10: ... iutput 5 pin XLR socket DMX output 3 pin XLR socket DMX output 5 pin XLR socket 4 4 Power Connection mains with the enclosed power cable and plug If you wish to change the power supply settings see the chapter appendix Connect the fixture to the L N CABLE EU CABLE US Pin Brown Black Live Yellow Green Green Earth Light blue White Neutral INTERNATIONAL 6 DMX512 DMX Terminator Diagram For installati...

Page 11: ...to avoid damaging of collision to arm 4 5 6 7 8 9 10 11 12 13 14 15 16 BACK PANEL 3 pin XLR female Network interface Power in Power switch Insurance seat Network interface 3 pin XLR male CINTROL PANEL Status indicator lamp MODE button UP button DOWN button ENTER button Touch screen LCD display 16 12 13 14 15 11 4 6 7 5 8 9 10 ...

Page 12: ...6 Dimension 8 15 381 6 69 170 5 7 20 35 1 1 5 27 24 45 621 13 54 344 7 19 17 48 252 9 92 ...

Page 13: ...e main interface press MODE button to view the software version press the UP DOWN can m odify the DMX address If the screen icon is green said DMX signal connection is normal this state can be used to check th elamps and lanterns and connection between the control table is normal LOGO 9 Can view the company LOGO web site hardware software version date menu interface This lamp can be set to turn of...

Page 14: ...welding of master IC EP3C E04 MBDInit Error E05 BD1Init Error E06 BD2Init Error E12 BusErr1 E14 SPDError Check the welding of master IC E16 MFpga Error E17 BD1 BUS Error E18 BD2 BUS Error E21 Pan FB Err E23 Tilt FB Err E22 Pan Zero Err E24 Tilt Zero Err E37 B Fan1 Error Check the fan of head E45 EthMDL Error Check the fan of ArtNet communication signal Check the communication signal 485 485 chip m...

Page 15: ...erse defaul OFF Tilt Reverse ON OFF Tilt Reverse defaul OFF Feedback ON OFF Pan Tilt Auto Switch defaul ON Wired Input Wired Input defaul Wireless Input Wireless Input Wireless In XLR out Wireless In XLR out Ethnet Input Ethnet Input Brightness Brightness Screen Time out 0 10m Screen Time out Touch Screen ON OFF Touch Screen defaul ON Auto Screen ON OFF Auto Screen defaul ON Auto High Reset Reset ...

Page 16: ...OFF 0 9 Red 10 Green 11 Blue 12 Cyan 13 Yellow 14 Magenta 15 White 7000 K 16 White 3700 K 17 White 5000 K 18 Black 19 Medium Yellow 20 22 Straw Tint 23 26 Surprise Peach 27 28 Fire 29 Medium Amber 30 Gold Amber 31 Dark Amber 32 34 Sunrise Red 35 44 Light Pink 45 Medium Pink 46 48 Pink Carnation 49 61 Light Lavender 62 67 Lavender 68 77 Sky Blue 78 88 Just Blue 89 99 Dark yellow green 100 109 Sprin...

Page 17: ...5 Pan Fine Pan Fine 0 255 UNUSED RANGE 0 2 CW Rotation speed from fast to slow 3 126 Stop Rotation 127 130 CW Rotation speed from slow to fast 130 255 17 17 17 17 17 17 Tilt Tilt 0 255 18 18 18 18 18 18 Tilt Fine Tilt Fine 0 255 UNUSED RANGE 0 2 CW Rotation speed from fast to slow 3 126 Stop Rotation 127 130 CW Rotation speed from slow to fast 130 255 Function off rearmed 0 11 Pan Tilt Fast Defaul...

Page 18: ...nterval 1 10 Single spaced interval 2 11 Single spaced interval 3 12 Single spaced interval 4 13 Reserve 14 255 Radius size Static 0 63 max to min speed 64 158 Stop 159 160 min to max speed 161 255 32 32 32 32 32 Shape Fade Shape Fade 0 100 0 255 33 33 33 33 33 Shape R Shape R 0 100 0 255 34 34 34 34 34 Shape G Shape G 0 100 0 255 35 35 35 35 35 Shape B Shape B 0 100 0 255 36 36 36 36 36 Shape W S...

Page 19: ...nout 4 25 Single point following runout 5 26 Square jitter 27 Strip spinning 28 Small strip beating 1 29 Small strip beating 2 30 Single point following runout 5 31 Reserve 32 255 Radius size Static 0 63 max to min speed 64 158 Stop 159 160 min to max speed 161 255 61 61 Pixels Shape Fade Shape Fade 0 100 0 255 62 62 Pixels Shape R Shape R 0 100 0 255 63 63 Pixels Shape G Shape G 0 100 0 255 64 64...

Page 20: ...Only replace the fuse by a fuse of same type and rating Before replacing the fuse unplug mains lead Maintenance and maintenance of the operation please contact the manufacturer or distributor DANGER Disconnect from the mains before starting any maintenance work Mode1 Mode2 Mode3 Mode4 Mode5 Mode6 Name Function DMX Value 48 76 Pixels 2 Dimmer Pixels 2 Dimmer 0 100 0 255 49 77 Pixels 2 Shape Fade Pi...

Page 21: ...imensions 621X252X381 NET WEIGHT 20Kg Dimensions WEIGHT Dimensions NET WEIGHT WEIGHT mm Carton Package mm Carton Package Flight Case 2 lights mm Flight Case 2 lights 735X470X390 25 5Kg 1260X680X558 71Kg 159Kg 10 3 Channel Characteristics 2 3 6 Seven standard DMX channel model 2 Scan Pan Tilt 360 arbitrary position 360 polerotation Fixture could auto reset 3 Shutter electronic shutter random strobe...

Page 22: ...e above contents for reference only and is subject to change without prior notice please take specification you have on hand and our company reserves the final right of interpretation 11 Electronic drawing 18 ...

Page 23: ......

Page 24: ...32 Changsha Street Shachong Village shiji Tow Panyu District Guangzhou China http www jollylight ing com Guangzhou hongcai stage equipment Co Ltd Tel 862084558833 Fax 862084559699 Email info jollylighting com P C 511450 ...