SM053 EN REV03 2015_10
Fireplace
10 kW and 14 kW
I N S T A L L A T I O N , U S E A N D MAINTENANCE MANUAL
To be kept by the purchaser
Pellet operated air heating fireplace
JOLLY SYNTHESIS 68-80
JOLLY STAR 68-80
Page 1: ...SM053 EN REV03 2015_10 Fireplace 10 kW and 14 kW INSTALLATION USE AND MAINTENANCE MANUAL To be kept by the purchaser Pellet operated air heating fireplace JOLLY SYNTHESIS 68 80 JOLLY STAR 68 80...
Page 2: ...y read and keep this sheet before using the equipment This sheet provides necessary information and suggestions on how to correctly install use clean and maintain the product Knowing and observing the...
Page 3: ...LS 18 06 5 DIMENSIONS 19 CHAP 07 POSITIONING AND CONNECTIONS FOR THE INSTALLER 20 07 1 POSITION OF EXTERNAL AIR INTAKES AND ELECTRIC CURRENT 20 07 2 ASSEMBLING AND INSTALLING THE FIREPLACE IN A PRE EX...
Page 4: ...appropriate This manual cannot be given to third parties for perusal without the written permission of Jolly Mec Caminetti S p A The technical directions for installation contained in this manual sho...
Page 5: ...d electrical appliances and similar products General safety regulations EN 60335 2 102 Safety of household electrical appliances and similar products Special regulations for appliances fitted with gas...
Page 6: ...ufacturer reserves the right to make modifications to the product and consequently the relative manual without any obligation to update previous editions 01 5 MANUFACTURER LIABILITY AND WARRANTY CONDI...
Page 7: ...tted for children persons with acknowledged reduced psycho physical and sensory abilities and persons who lack experience in using such machines unless they are supervised by designated persons respon...
Page 8: ...is installed Installation in bedrooms rooms with a volume below 15 m3 or with explosive atmospheres is strictly prohibited The system installer MUST issue a Declaration of compliance for the work per...
Page 9: ...EQUIPMENT FOR OPERATORS AND MAINTENANCE PERSONNEL Every operator performing maintenance on the machine must wear safety garments and personal protective equipment 1 Protection headphones 2 Gloves han...
Page 10: ...TRANSPORT Personnel in charge of handling the product must have read and thoroughly understood the safety prescriptions in CHAP 02 ACCIDENT PREVENTION SAFETY REGULATIONS of this manual and must wear...
Page 11: ...ur and DO NOT disperse the packaging into the environment but take it to waste disposal centres for recycling All packaging can be recycled as it consists of wood polyethylene film polystyrene and car...
Page 12: ...the wall and pre disposed for ducting hot air to other areas with special insulated aluminium pipes It is also equipped with a convenient chute for loading pellets into the hopper and can be positione...
Page 13: ...safety device against possible overheating Safety device against possible clogging of the flue pipe Tangential Fan for hot air exchange in the environment Fume exhaust fan Electrical resistance to st...
Page 14: ...Stoffen Distance mat riaux combustibles adjacents Distancia a materiales combustibles adyacentes Utilizzare solo combustibili raccomandati Use recommended fuels only Verwenden Sie nur die empfohlenen...
Page 15: ...2 reduced output 3 30 mg Nm3 CO2 nominal output 9 13 9 020 Nominal fume mass output 8 70 11 12 g s Reduced fume mass output 5 00 g s Minimu distance from inflammable material frontal side rear 1000 30...
Page 16: ...hat are very hard and with different dimensions the mechanical parts are sized and tested for use with pellets with the above mentioned characteristics No breakdown or malfunction depending on the qua...
Page 17: ...ssostat 5 Support base with runners 6 Emergency console 7 Combustion fan and fume discharge 8 Runners for inset fireplace extraction 9 Humidifier Accessible by opening the door 10 Air damper regulatin...
Page 18: ...the comburent air intake it prevents insect entrance within the home The mesh must be periodically cleaned since dust pollen or humidity can obstruct air passage through the grate over time Fume conne...
Page 19: ...lace JOLLY SYNTHESIS 68 80 Inset fireplace for a new fireplace and ducting JOLLY STAR 68 80 The pellet chute for loading the hopper can be assembled according to the cladding that has been chosen on t...
Page 20: ...exchange 120 3 Create the room with the measurements shown starting 65mm from the wire glass front 4 Internal air intake 80 for air circulation inside environment or to levy combustion air 5 Electrica...
Page 21: ...tput the cassette fireplace requires see par 06 1 3 If air ducting is provided see par 07 4 07 5 Phase 2 Unscrew the two nuts A a rail and the two screws B a rail which secure the inset fireplace onto...
Page 22: ...ssem bled on its easel Read carefully and follow chap 10 1 for the AIR CANALISATION GROUP and PELLET CHUTE ASSEMBLING Phase 1 Place the fireplace complete with the AIR CANALI SATION GROUP and PELLET L...
Page 23: ...e air pipes must be brought to the rooms to be heated From every room where hot air is ducted the air must return to the fireplace room through openings beneath the doors or vents which must be taken...
Page 24: ...s impossible to wall up the distribution pipes they can be hidden with a suspended ceiling fake beams or casing The space between the vents and the wall must be hermetically sealed with silicone A to...
Page 25: ...e cement for connecting the equipment to the flue is forbidden Exhaust pipes must not run through rooms where the installation of combustion equipment is forbidden The union must be connected to the f...
Page 26: ...ression alarm It is not possible to make corrections or reset the stove operating values to override the alarm 07 7 INSTALLATION ROOM VENTILATION According to reference regulation UNI10683 4 Pa depres...
Page 27: ...ctions and is co trolled by remote control see par 08 4 The radio frequency control unit operating by the antenna located in the left lateral part of the cassette fireplace and connected to the consol...
Page 28: ...switch and fuse holder for the electric network 4 Electric power cord with schuko socket 5 Combustion fumes exhaust fan 6 Pellet start up electric resistance 7 Hot air exchange centrifugal fan 8 85 C...
Page 29: ...he drawer The fireplace is equipped with an exchanger in steel and dual heat developing FIREFLECTOR closed in front by a door in ceramic glass The quantity of fuel the feeding of comburent air and the...
Page 30: ...ONTROL M10 P The remote control M10 P lets you use the following main functions Device start and stop 5 heating output level adjustment Regulate the desired ambient temperature Optimise combustion Man...
Page 31: ...must always be closed during normal operations The pellet hatch must be closed while the machine is running Check for obstructions in the flue and in the external air intake before starting the machin...
Page 32: ...rmance and the chimney cap A windproof chimney cap is strongly recommended Ash compartment cleaning Remove the ash grid and empty the pellet ash compartment periodically whenever necessary The purpose...
Page 33: ...shes and residues 7 Reassemble all parts following the sequence carefully Recommended cleaning once a month but check the manual Loading the pellet hopper Jolly Synthesis 68 80 model The pellet hopper...
Page 34: ...a year to be verified according to the usage To carry out these operations the electrical current must be turned off you must wait until the fireplace is cold and comply rigorously with the safety reg...
Page 35: ...ly and check it is clean each time you start it up The basket is positioned incorrectly The resistance is faulty The pellets burn poorly and uncombusted material forms in the basket the glass gets ver...
Page 36: ...properly Check to see if the stove is dirty and clean it if necessary Check to see if the PELLET load settings are correct Contact the CAT if this type of alarm is tripped frequently AL04 vacuum fail...
Page 37: ...ipped frequently AL07 thermal safety Tripped thermal safety switch The fireplace has overheated caused by exchange fan is not working excessive PELLET load very dirty stove The thermal safety switch i...
Page 38: ...uired component to fix it and the components of the canalisation group and pellet load chute see Fig 2 1 Lateral shaft to fix the easel n 2 pcs 2 Assemble the lateral shaft for canalisation nr 2 pcs 3...
Page 39: ...s and washers in the equipment following the installation type 2 Fix the lateral shafts 2 Fig 4 using the screws M8x16 with their nuts and washers without tightening it only preassembly it 3 Fix the t...
Page 40: ...t of the hot air box and check that by sliding the fireplace in and out everything is fitting correctly see the included instruction manual for the opening Before you start to extract the fireplace ve...
Page 41: ...ews M8x16 the nuts and the washers in the equipment inside the upper bar with the help of the upper holes depending from the position chosen and fix tightly 8 Using the two lateral screws Fig 9 on the...
Page 42: ...42 NOTES...
Page 43: ...43 ENGLISH...
Page 44: ...SM053 EN REV03 2015_10 Via S Giuseppe 2 24060 Telgate Bg Italy Tel 39 035 83 59 211 Fax 39 035 83 59 203 www jolly mec it info jolly mec it...