![Johnson J10RLSUR Service Manual Download Page 78](http://html1.mh-extra.com/html/johnson/j10rlsur/j10rlsur_service-manual_2022850078.webp)
76
ELECTRICAL
ELECTRIC STARTER TESTS
STEP 4
Connect voltmeter positive (+) lead to battery neg-
ative (–) lead common powerhead ground screw.
Connect voltmeter negative (–) lead to battery
negative (–) post. Turn key switch to START.
•
Voltage reading must not be more than 0.3 volt.
STEP 5
Clean and tighten, or replace, any connection,
cable, or other component that does not meet the
specified values.
Starter Solenoid Test
IMPORTANT:
All engine wiring must be discon-
nected from the solenoid before proceeding.
STEP 1
Connect one ohmmeter lead to terminal (A) and
the other lead to terminal (B).
•
Ohmmeter must show a high reading.
•
If ohmmeter shows a low reading, replace the
solenoid.
STEP 2
With the ohmmeter still connected, attach a posi-
tive (+) battery jumper to terminal (C) and a nega-
tive (–) battery jumper to terminal (D). The
solenoid should close with an audible click.
•
Ohmmeter must show a low reading.
•
If ohmmeter shows a high reading, replace the
solenoid.
After installing the solenoid, coat all wires and ter-
minals with
Black Neoprene Dip
.
DRC4032
≤
0.3V
24082
B
A
C
D
Summary of Contents for J10RLSUR
Page 1: ......
Page 2: ......
Page 147: ...POWERHEAD POWERHEAD VIEWS 145 7 POWERHEAD VIEWS Port Starboard View Manual Start DP0019 DP0020...
Page 148: ...146 POWERHEAD POWERHEAD VIEWS Rear View Manual Start DP0021...
Page 194: ...S 2...
Page 223: ...DR4698 Water Flow Diagram 9 9 15HP...
Page 228: ...A B C D E B C D E A 9 9 15HP DRC 6217 2 1...
Page 229: ......