MN1010 Rev. G
7 of 25
2
Functional Description
2.1
Readings screen
Attention
: Tracerco recommends that the time before screensaver activation should be kept as low as practical as
long periods of screen activity reduce the lifetime of the screen.
PEDs have the following display modes:
•
Combined dose and dose rate (this is the default screen layout)
•
Dose rate only (includes peak dose rate)
•
Dose only (includes stay time).
PEDs also have an option to flip the screen. The display modes are as follows:
Combined
Dose rate only
Dose only
The readings screens show the following information depending on the screen selected:
Peak reading
The highest rate of dose, µSv/h or mrem/h, detected since the last time the readings were transferred to
DoseVision™.
Stay time
An estimate of the time left at current dose rate, until you reach the next dose alarm. The stay time is
displayed in minutes with a range of 0 to 999 minutes.
Dose
The total dose of radiation, µSv/h or mrem/h, received since the last readings were added onto
DoseVision™.
Dose body
Graphical display of accumulated dose level. The body fills from the bottom as dose is accumulated.
Yellow, orange and red and dark red (crimson) dose alarm thresholds are displayed on the figure
depending on the alarm configuration.
Bar graph
Graphical display of current dose rate (linear scale). Orange and red dose rate alarm thresholds are
displayed on the bar graph.
Rate
Current dose rate in µSv/h or mrem/h.