VFD67 Size A to D Getting Started Guide
37
Issue Number: 1
www.johnsoncontrols.com
Sa
fe
Rat
in
Me
ch
El
Ke
yp
P
Qu
ick S
D
P
Te
UL L
Defines the brake release and brake apply frequencies.
If the current is >Pr
46
and the frequency is > Pr
48
, the brake release sequence is
started.
If the frequency is <Pr
49
and the drive has been commanded to stop, the brake is
applied immediately.
Defines the time between the frequency and load condition being met and the brake
being released. The ramp is held during this time.
Defines the time between the brake being released and the ramp hold being released.
Figure 6-12 Brake function diagram
No
Function
Range
Defaults
Type
48
Brake release frequency
0.0 to 20.0 Hz
1.0
RW
49
Brake apply frequency
2.0
No
Function
Range
Defaults
Type
50
Pre-brake release delay
0.0 to 25.0 s
1.0
RW
No
Function
Range
Defaults
Type
51
Post brake release delay
0.0 to 25.0 s
1.0
RW
Current
magnitude
Brake release
current threshold
Brake apply
current threshold
46
47
+
_
Motor
frequency
Brake release
frequency
Brake apply
frequency
48
49
+
_
+
_
Reference
enabled
Latch
Drive
active
In
Out
Reset
Pre-brake
release
delay
50
Post brake
release
delay
51
Brake
release
Brake
controller
enable
12
T5
T6
B3
User
programmable
Brake
disabled
Ramp
hold
88
85
91