Section 6: Programming
OFF: When a trouble is detected on the system, trouble beeps are sounded at the keypad.
Note:
This option must be OFF for UL Residential Fire applications.
Note:
To silence the Fire Trouble beep, press [*][2] and exit. Accessing [*][2] requires a valid user code.
8 – Keyswitch Arms in Away Mode
ON: Keyswitch arming arms the alarm system in away mode.
OFF: Keyswitches only arm the system in away mode if an entry/exit zone is violated during exit delay.
Note :
Proximity tag arming follows this section.
[023] System Option 11
1 – Ready LED Flashes for Force Arm
ON: If a force arm capable zone is tripped, partition keypads flash the ready LED in the disarmed state instead of illuminating it
steadily. If a non-force arm capable zone is tripped, the ready LED turns off.
OFF: If a force arm capable zone is tripped, the Ready LED is illuminated steadily. If a non-force arm capable zone is tripped, the
Ready LED turns off.
2 – Access Code Required for [*][*]
ON: When using the [*][*] Temperature Display Menu command, an access code must be input before the temperature menu can be
viewed.
OFF: An access code is not required to view the temperature menu using [*][*].
EN
3 – Tamper/Fault Detection
ON: The following trouble conditions, when configured to generate audible alarm conditions, will contribute to a burglary verification
sequence when sequential detection is used. When enabled, a bell circuit trouble will also generate an audible alarm condition using
other sirens that assigned to the partition.
l
TLM trouble
l
Bell circuit trouble
l
Zone fault
l
Module supervisory trouble
l
Alternate Communicator fault
l
Ethernet Trouble
l
Zone Mask Fault
OFF: Trouble conditions are displayed and processed as standard operation.
Note:
This option applies to the Sequential Detection feature only.
EN
4 – Access Code Required for [*][1]
ON: When using the [*][1] Bypass Zones command, an access code must be input before zones are bypassed.
OFF: An access code is not required to bypass zones using [*][1].
EN
5 – Access Code Required for [*][2]
ON: When using the [*][2] View Troubles command, an access code must be input before system troubles can be viewed.
OFF: An access code is not required to view troubles using [*][2].
Note:
For UL Residential installations, ensure the access code requirement is set to ON.
EN
6 – Access Code Required for [*][3]
ON: When using the [*][3] View Alarms in Memory command, an access code must be input before the alarm memory can be viewed.
OFF: An access code is not required to view alarms in memory using [*][3].
7 – Access Code Required for [*][4]
ON: When using the [*][4] Chimes command, an access code must be input before chimes can be toggled on and off.
OFF: An access code is not required to toggle chimes using [*][4].
8 – [*][6] Accessibility
ON: All user codes provide access to the [*][6] menu.
OFF: Only the master code provides access to the [*][6] menu.
- 118 -