Keypad Programming
- 13 -
Note:
For UL/ULC installations, bit 5 (Power LED) and bit 6 (Power LED Indicates AC Present) shall be ON.
[023] Third Keypad Options
Default Value Option ON
Off
OFF
|__|
1
Armed LED Power Save
Armed LED Off in Sleep Mode
ON
|__|
2
Keypad Status Shows Stay Arm
Keypad Status Shows Stay/Away Arm
OFF
|__|
3
5th Terminal Keypad PGM Output
5th Terminal is Keypad Zone Input
ON
|__|
4
Prox tag will arm/disarm
Prox tag does not arm/disarm
OFF
|__|
7
Local Display of Temperature
No Local Display of Temperature
OFF
|__|
8
Low Temperature Warning Enabled Low Temperature Warning Disabled
[030] Download LCD Messages
|___|___|___|___|___|___|___|___|___|___|___|___|___| ___|
|___|___|___|___|___|___|___|___|___|___|___|___|___| ___|
[031] Download LCD Message Duration
Default: 000 |___|___|___|
(Valid entries are 000-255, 000=Unlimited Msg Display) This number represents the number of times the down-
loaded message must be cleared before it is permanently removed. This message can be cleared by pressing any
key.
[041] Indoor Temperature Zone Assignment
Default: 000 |___|___|___| (Valid entries are 000-248)
[042] Outdoor Temperature Zone Assignment
Default: 000 |___|___|___| (Valid entries are 000-248)
[101] - [348] Door Chime for Zones 1 - 248
The keypad can be programmed to make up to four different chime sounds for individual zones (e.g., for Zone 1,
enter section [101], for Zone 2 enter section [102]).
Default: 01 |___|___|
Valid Entries
01 6 Beeps
02 Bing-Bing tone
03 Ding-Dong tone