Johnson Controls TrueRH Series Installation Instructions Manual Download Page 1

 

24- 7701- 187,   Rev.   B

 

 
 

Installation Instructions  HT-670x 

 

Issue Date  March 2016

 

©  2016 Johnson Controls, Inc.

 

1

 

  Part No. 24-7701-187, Rev. B 

www.johnsoncontrols.com 

T

RUE

RH™ Series HT-670x Humidity Transmitters 

 

Application Requirements 

Configure the transmitter for the output signal required 
prior to installation. Proceed to the appropriate 
transmitter section to change the factory setting. 

Installation 

The humidity transmitter is available in both a wall 
mount or duct probe package to suit a variety of 
sensing application needs. 

Parts Included 

 

mounting base for U.S. wallbox or surface 
mounting 

 

No. 6-32 x 7/8 in. oval-head screw (2) 

 

No. 4-40 x 1/4 in. hex-head cover screw (in the 
mounting base) 

 

drywall clip mounting kit (includes two each 
No. 6-20 x 1.25 in. pan-head tapping screws, 
spring clips, and spacers) 

IMPORTANT: 

The HT-670x Series Humidity 

Transmitter is intended to provide an input to 
equipment under normal operating conditions. 
Where failure or malfunction of the HT-670x Series 
Humidity Transmitter could lead to personal injury or 
property damage to the controlled equipment or 
other property, additional precautions must be 
designed into the control system. Incorporate and 
maintain other devices, such as supervisory or alarm 
systems or safety or limit controls, intended to warn 
of or protect against failure or malfunction of the 
HT-670x Series Humidity Transmitter 

IMPORTANT: 

Le HT-670x Series Humidity 

Transmitter est destiné à transmettre des données 
entrantes à un équipement dans des conditions 
normales de fonctionnement. Lorsqu'une défaillance 
ou un dysfonctionnement du HT-670x Series 
Humidity Transmitter risque de provoquer des 
blessures ou d'endommager l'équipement contrôlé 
ou un autre équipement, la conception du système 
de contrôle doit intégrer des dispositifs de protection 
supplémentaires. Veiller dans ce cas à intégrer de 
façon permanente d'autres dispositifs, tels que des 
systèmes de supervision ou d'alarme, ou des 
dispositifs de sécurité ou de limitation, ayant une 
fonction d'avertissement ou de protection en cas de 
défaillance ou de dysfonctionnement du  
HT-670x Series Humidity Transmitter. 

Accessories 

Table 1: Accessories and Replacement Parts for Wall Mount Humidity Transmitters 

Product Code Number 

Description 

ACC-DWCLIP-0 

Drywall Clip Mounting Kit (10/bag) 

ACC-INSL-0* 

Wallbox Mounting Pad (10/bag) 

ACC-INSL-1* 

Surface Mounting Pad (10/bag) 

GRD10A-608 

Plastic Guard with Baseplate and Mounting Ring 

T-4000-119 

Allen-head Adjustment Tool (30/bag) 

TE-67MB-600 

Mounting Base Kit 

TE-67D0-601** 

Door Replacement Kit with Johnson Controls logo 

TE-67D0-602** 

Door Replacement Kit without logo 

*  These foam pads help prevent drafts from entering the unit through the wall and make installation easier when mounting 
on an uneven surface. 

**  Contains 10 original style and 10 new style doors. 

Summary of Contents for TrueRH Series

Page 1: ...against failure or malfunction of the HT 670x Series Humidity Transmitter IMPORTANT Le HT 670x Series Humidity Transmitter est destin transmettre des donn es entrantes un quipement dans des condition...

Page 2: ...eful not to drop or mount the unit where it could be exposed to excessive vibration The following ambient operating conditions apply Temperature 32 to 122 F 0 to 50 C Humidity 0 to 100 Relative Humidi...

Page 3: ...spacers for 5 8 in 16 mm drywall Note For replacement spring clips spacers and screws order the ACC DWCLIP 0 Drywall Clip Mounting Kit See Table 1 Base Cover Screw Cover Figure 4 Removing the Breakawa...

Page 4: ...ay be exposed to condensation To mount the duct probe humidity transmitter refer to Figure 6 and proceed as follows 1 Remove any excess insulation from the duct that prevents the probe from extending...

Page 5: ...ply 16 to 30 VDC Note Output is not used Common Figure 8 Wiring with Output Jumper Set for 4 to 20 mA Once installed the unit cannot be removed from the wall unless the cover screw is loosened as desc...

Page 6: ...sunlight for example 2 Check all supply voltage connections and make sure the wiring is correct Refer to Figure 10 or Figure 11 for the duct probe transmitter and Figure 7 or Figure 8 for the wall mou...

Page 7: ...0 to 80 C 0 to 100 RH noncondensing 85 F 29 C maximum dew point Materials Wall Mount White plastic enclosure for surface or standard wallbox mounting including hardware Duct Probe White plastic cover...

Reviews: