background image

TEC20x6(H)-4 and TEC20x6H-4+PIR Series Wireless Thermostat Controllers with Dehumidification 
Capability, Fan Control, and Occupancy Sensing Capability 

24

Technical Specifications

Table 8:  Accessories (Order Separately)

Code Number

Description

SEN-600-1

Remote Indoor Air Temperature Sensor

SEN-600-4

Remote Indoor Air Temperature Sensor with Occupancy Override and LED

TE-6361M-1

1

Duct Mount Air Temperature Sensor

TE-636S-1

Strap-Mount Temperature Sensor

TEC20-A-1

Replacement Antenna for TEC20 Coordinator

TEC20-RA-1

2

Remote Antenna for TEC20 Coordinator

NPB-PWR

3

DIN Rail Mount 24 VAC/DC Power Module for TEC20 Coordinator

TEC20-8X-1

120 VAC to 15 VDC Power Supply for TEC20 Coordinator

TEC20-9B-1

Replacement Battery Pack for TEC20 Coordinator

TEC-6-PIR

4

Cover with Occupancy Sensor

TEC-6H-PIR

5

Cover with Occupancy Sensor for Hospitality Models

1.

Additional TE-636xx-x Series 10k ohm Johnson Controls Type II Thermistor Sensors are available; refer to the 

TE-6300 Series Temperature Sensors Product Bulletin (LIT-216320)

 for more details.

2.

This antenna is used when the TEC Coordinator is installed inside a metal cabinet, or when a remote antenna is required by 
physical installation.

3.

DIN Rail: Type NS35/7.5 (35 x 7.5 mm) and DIN rail end clips. Length of DIN rail depends on the number of DIN rail 
mounted options.

4.

The TEC-6-PIR Accessory Cover can be used to replace the existing cover on a non-PIR TEC20x6-4 Series Thermostat 
Controller to provide occupancy sensing capability.

5.

TEC-6H-PIR Accessory Cover can be used to replace the existing cover on a non-PIR TEC20x6H-4 Series Thermostat 
Controller to provide occupancy sensing capability.

TEC20x6(H)-4 and TEC20x6H-4+PIR Series Wireless Thermostat Controllers with 
Dehumidification Capability, Fan Control, and Occupancy Sensing Capability (Part 1 of 2)

Power Requirements

19 to 30 VAC, 50/60 Hz, 2 VA (Terminals 4 and 5) at 24 VAC Nominal, Class 2 or 
Safety Extra-Low Voltage (SELV)

Relay/Triac Contact Rating

On/Off and Floating Control:

 19 to 30 VAC, 1.0 A Maximum, 15 mA Minimum,

3.0 A In-Rush, Class 2 or SELV

Analog Output Rating 

Proportional Control:

 0 to 10 VDC into 2k ohm Resistance (Minimum)

Fan Relay Output Rating

19 to 30 VAC, 1.0 A Maximum, 15 mA Minimum, 3.0 A In-Rush, Class 2 or SELV

Auxiliary Output Rating

Triac Output:

 19 to 30 VAC, 1.0 A Maximum, 15 mA Minimum, 3.0 A In-Rush

Binary Inputs

Voltage-Free Contacts across Terminal Scom to Terminals BI1, BI2, or UI3

Analog Inputs

Resistive Inputs (RS and UI3) for 10k ohm Johnson Controls Type II Negative 
Temperature Coefficient (NTC) Thermistor Sensors

Wire Size

18 AWG Maximum, 22 AWG Recommended

Recommended Transmission 
Range

Through Walls: 

10 m (30 ft)

Line-of-Sight (Open Space): 

30 m (100 ft)

RF Band

Direct-Sequence Spread-Spectrum Transmission; 2.4 Ghz unlicensed band

Transmission Power

10 mW Maximum

Temperature Range

Backlit Display:

 -40.0°C/-40.0°F to 50.0°C/122.0°F in 0.5° increments

Heating Control:

 4.5°C/40.0°F to 32.0°C/90.0°F in 0.5° Increments

Cooling Control: 

12.0°C/54.0°F to 38.0°C/100.0°F in 0.5° Increments

Temperature Sensor Type 

Local 10k ohm Negative Temperature Coefficient (NTC) Thermistor

Resolution 

±0.1C°/±0.2F°

Summary of Contents for TEC20x6-4 Series

Page 1: ...less Thermostat Controllers are intended to provide an input to equipment under normal operating conditions Where failure or malfunction of the thermostat controller could lead to personal injury or p...

Page 2: ...Metasys System Location Guide LIT 12011294 Installing the Thermostat Controller Follow these steps to install the thermostat controller 1 Use a Phillips head screwdriver to remove the security screw...

Page 3: ...u have enough space for cabling and end of line devices if needed Note For surface mount applications use durable mounting hardware such as Molly bolt anchors that cannot be easily pulled out of the m...

Page 4: ...ire back into the wall Note Seal the hole in the wall with fireproof material to prevent drafts from affecting the ambient temperature readings 3 Reinsert the screw terminal blocks onto the PCB Note I...

Page 5: ...EC20x6H 4 PIR Series Thermostat Controller Terminals Figure 6 TEC20x6 H 4 and TEC20x6H 4 PIR Series Thermostat Controller with Separate Power Source for Auxiliary Contact FIG TEC20x6H4_SEP BI2 UI3 BI1...

Page 6: ...Aux BO5 Aux BO5 Aux Auxiliary Binary Output 8 BO3 BO3 Blank Open Heat 9 Blank BO4 AO2 Close Heat 10 Blank BO1 AO1 Open Cool 11 BO2 BO2 Blank Close Cool 12 BI1 BI1 BI1 Configurable Binary Input 1 13 R...

Page 7: ...ting Valve 24 V Hot BO3 N C Cooling Valve FIG TEC2016H4_onoff Figure 9 Wiring TEC2026 H 4 TEC2026H 4 PIR TEC2036 H 4 and TEC2036H 4 PIR Thermostat Controllers for On Off Control Two Pipe Applications...

Page 8: ...key also allows access to the Installer Configuration Menu See the Configuring the Thermostat Controller section C F key hospitality models changes the temperature scale to either Celsius or Fahrenhe...

Page 9: ...te For models with dehumidification capability the default setting is no humidity reading on the display RH disp parameter is set to off The RH disp parameter must be set to on to display the current...

Page 10: ...tic LEDs The diagnostic LEDs inside the PIR lens brighten when movement is detected within the first 30 minutes after powerup The LEDs do not light up or brighten after the initial 30 minute period Se...

Page 11: ...he UP DOWN arrow keys to choose the desired selection option 4 Press and release the center key to continue scrolling through the parameters St By Heat 69 F Occ Heat 72 F Occ Cool 75 F St By Cool 78 F...

Page 12: ...ration SeqOpera Choose the appropriate sequence of operation The modes presented are user dependent on the sequence of operation selected For two pipe applications using a changeover sensor choose the...

Page 13: ...Cooling with Reheat See Figure 18 6 and 7 Reheat 10 N O Cooling 11 N C Cooling 6 and 7 Reheat 10 Open Cooling 11 Closed Cooling 6 and 7 Reheat 10 Proportional Cooling 3 Heating with Reheat See Figure...

Page 14: ...Temperature Increase Increments of 1F 0 5C Heating Setpoint Device Closed Cooling Setpoint Device Opened FIG clng_wth_rht Deadband Reheat On Off Floating or Proportional Outputs Heating Output Cooling...

Page 15: ...tting Figure 22 This operation applies to the occupied mode when the fan is set to Auto Temperature Increase Increments of 1F 0 5C Heating Setpoint Device Closed Device Closed Device Opened Cooling Se...

Page 16: ...e fan to low speed the chilled water valve opens to the specified maximum value set by CoolMax the thermostat controller stages Heating to maintain the room temperature at the Cooling setpoint as sens...

Page 17: ...ted if the Fan Menu parameter is set to 4 On Auto and Auto is the selected fan mode A window alarm appears indicating that the window needs to be closed to resume heating or cooling These settings dis...

Page 18: ...mperature is available as a point for integration and UI3 Status is not available as a point for integration MenuScro Gives the option of having the display continuously scroll the parameters Default...

Page 19: ...Only when using a changeover sensor to allow changeover to occur between Cooling Only and Heating Only Choose the selection option 2 Cooling and Reheat when using a changeover sensor to allow changeo...

Page 20: ...from drifting from stand by mode to unoccupied mode when occupancy sensor functions are used Range 0 0 to 24 0 hours in 0 5 hour increments St By HT Sets Stand by heating setpoint when used with occu...

Page 21: ...int Adjustment The displayed setpoint is the setpoint from the last action taken by the thermostat controller or the setpoint currently in use Both the heating and cooling setpoints are changed simult...

Page 22: ...use this selection option 5 Auxiliary On Off control through the auxiliary network command The output can be commanded through the network for any required auxiliary functions via a separate and dedi...

Page 23: ...e acting 0 to 100 10 to 0 VDC DA Direct acting 0 to 100 0 to 10 VDC Reheat Sets the duty cycle time for reheat output if Option 2 3 or 5 is chosen in the SeqOpera parameter Default 0 1 10 seconds six...

Page 24: ...y sensing capability 5 TEC 6H PIR Accessory Cover can be used to replace the existing cover on a non PIR TEC20x6H 4 Series Thermostat Controller to provide occupancy sensing capability TEC20x6 H 4 and...

Page 25: ...le E27734 CCN XAPX Under UL 873 Temperature Indicating and Regulating Equipment FCC Compliant to Part 15 247 Regulations for Low Power Unlicensed Transmitters Transmitter FCC Identification pending Ca...

Reviews: