![Johnson Controls NEO Series User Manual Download Page 18](http://html.mh-extra.com/html/johnson-controls/neo-series/neo-series_user-manual_2023807018.webp)
User Manual: NEO System
18
Rev.0.3
2.4.4 External Systems Slot Interface
The equipment has a slot where the ETX-1 module can be integrated. This module allows
connection to NEO-Extension units, the control, monitoring and configuration through the data
network, the reception of audio sources from the data network and the integration with third-
party systems. The ETX-1 module is delivered as part of the equipment.
Figure 15 - External Systems Slot Interface
a)
System Connection: Port X
The X port allows the connection of an external Ethernet network that can be used for
control, monitoring and configuration and the reception of audio over the data network. It
is possible to configure this port to be disabled during emergency mode, therefore
enhancing the security of the internal network.
b)
System Connection: Ports A and B
The equipment has two ports for connecting other systems and
NEO-Extension units. The behavior of these ports can be
configured by a dip-switch as indicated in section (e). The
default mode will be position 01, where A will be the main
Flexnet connection and B the redundant Flexnet connection. In
case of failure in port A, the system will automatically switch to
port B.
The connection is made using standard CAT5 Ethernet network cable RJ-45 T568B (the
connection cable is supplied with the equipment).
Markin
g
Description
Type
Signals
Activation
X/A/B
Ports for system connection
Port
Ethernet
CAT5
Flexnet (propriety protocol)
UDP
Cobranet
Table 7 - System Connection Ports
c)
USB Port (Reserved)
The USB port (mini USB type AB) integrated in the equipment is reserved.
d)
Integration Serial Port
The equipment has a two-wire RS-485 serial port. The default configuration for
events for integration with third party systems is: 19200bps, 8 bits, even party
bit, 1 stop bit.
Figure 17 - USB Port
Figure 16 - System