5724452-UIM-A-0619
Johnson Controls Ducted Systems
9
TABLE 5:
Default Blower Speeds for FER Compliance - Electrical Heat Only
Model Number
High Sales Volume
Heat Kit
1,2,3
Nom. kW
@240 V
Default Blower Speeds
w1/[w1+w2]
Heat
Max. Airflow
Continuous Fan
ME08B
6HK(0,1)6500506
4.8 kW
w1
Medium (3)
High (5)
Low (1)
ME12B
6HK(0,1)6500806
7.7 kW
w1
Medium (3)
High (5)
Low (1)
ME12C
6HK(0,1)6501006
9.6 kW
w1
Medium (3)
High (5)
Low (1)
ME14D
4
6HK(1,2)6501506
14.4 kW
w1+w2
Medium (3)
High (5)
Low (1)
ME16C
4
6HK(1,2)6501506
14.4 kW
w1+w2
Medium Low (2)
High (5)
Low (1)
ME20D
6HK(1,2)6502006
19.2 kW
w1
Low (1)
High (5)
Low (1)
1. (0,1) - 0 = no service disconnect OR 1 = with service disconnect
2. (1,2) - 1 = with service disconnect, no breaker jumper bar OR 2 = with service disconnect and breaker jumper bar
3. 6HK3 = 3-phase with terminal block connectors only. 6HK4 = 3-phase with service disconnect
4. For ME14D and ME16C models with a 15 kW (6HK*65015**) heat kit, tie the AHU W1 and W2 thermostat inputs together for FER compliance.
TABLE 6:
KW and MBH Conversions - For Total Power Input Requirement
For a power distribution voltage that is different than the provided nominal voltage, multiply the kW and MBH data from the table by the conversion
factor in the following table.
DISTRIBUTION POWER
NOMINAL VOLTAGE
CONVERSION FACTOR
208 V
240 V
0.75
220 V
240 V
0.84
230 V
240 V
0.92
TABLE 7:
Electric Heat Performance Data: 208/230-1-60 and 208/230-3-60
Heater Models
1,2,3
Nominal kW
@240 V
Total Heat
4
kW Staging
kW
MBH
W1 Only
W1 + W2
208 V
230 V
208 V
230 V
208 V
230 V
208 V
230 V
1PH
6HK(0,1)6500206
2.4
1.8
2.2
6.2
7.5
1.8
2.2
1.8
2.2
6HK(0,1)6500506
4.8
3.6
4.4
12.3
15
3.6
4.4
3.6
4.4
6HK(0,1)6500806
7.7
5.8
7.1
19.7
24.1
5.8
7.1
5.8
7.1
6HK(0,1)6501006
9.6
7.2
8.8
24.6
30.1
7.2
8.8
7.2
8.8
6HK(1,2)6501306
12.5
9.4
11.5
32
39.2
3.1
3.8
9.4
11.5
6HK(1,2)6501506
14.4
10.8
13.2
36.9
45.1
3.6
4.4
10.8
13.2
6HK(1,2)6501806
17.3
13
15.9
44.3
54.2
6.5
7.9
13
15.9
6HK(1,2)6502006
19.2
14.4
17.6
49.2
60.2
7.2
8.8
14.4
17.6
6HK(1,2)6502506
24
18
22
61.5
75.2
7.2
8.8
18
22
3PH
6HK36501025
9.6
7.2
8.8
24.6
30.1
7.2
8.8
7.2
8.8
6HK36501525
14.4
10.8
13.2
36.9
45.1
10.8
13.2
10.8
13.2
6HK36501825
17.3
13
15.9
44.3
54.2
6.5
7.9
13
15.9
6HK46502025
19.2
14.4
17.6
49.2
60.2
7.2
8.8
14.4
17.6
6HK46502525
24
18
22
61.5
75.2
9
11
18
22
1. (0,1) - 0 = no service disconnect OR 1 = with service disconnect
2. (1,2) - 1 = with service disconnect, no breaker jumper bar OR 2 = with service disconnect and breaker jumper bar
3. 6HK3 = 3-phase with terminal block connectors only. 6HK4 = 3-phase with service disconnect
4. For different power distributions, see the conversion table above.