Section 5: Programming

l

Bell Squawk on arm (single)

l

Bell Squawk on disarm (double)

l

Bell Duration Auto-Arm (single every second)

l

Bell Squawk on Exit (single every second)

l

Bell Squawk on Entry (single every second)

l

Bell Squawk on Trouble (single every 10 seconds)

OFF: Squawks do not activate the main siren.

[001]-[324] PGM 001-324 Attributes

The following PGM attributes can be assigned to a PGM. Each attribute has various toggle options, depending on the PGM
type selected (section [009]).

101 – Fire and Burglary

01 – True Output/Inverted

ON: deactivated during normal operation. Activated when triggered.

OFF: active during normal operation. Deactivated when triggered.

102 – Delay Fire and Burglary

01 – True Output/Inverted

ON: deactivated during normal operation. Activated when triggered.

OFF: active during normal operation. Deactivated when triggered.

103 – Sensor Reset [*][7][2]

01 – True Output/Inverted

ON: deactivated during normal operation. Activated when triggered.

OFF: active during normal operation. Deactivated when triggered.

03 – Access Code Required / No Code Required

ON: Access code required for activation

OFF: No access code required for activation

107 – External Siren

01 – True Output/Inverted

ON: deactivated during normal operation. Activated when triggered.

OFF: active during normal operation. Deactivated when triggered.

109 – Courtesy Pulse

01 – True Output/Inverted

ON: deactivated during normal operation. Activated when triggered.

OFF: active during normal operation. Deactivated when triggered.

111 – Keypad Buzzer Follow

01 – True Output/Inverted

ON: deactivated during normal operation, activated when triggered.

OFF: activated during normal operation, deactivated when triggered.

02 – Timed Output

ON: output remains active until the PGM output timer expires.

OFF: output remains active until the buzzer condition ends.

09 – Entry Delay

ON: activates on entry delay.

OFF: does not activate on entry.

10 – Exit Delay

ON: activates on exit delay.

OFF: does not activate on exit delay.

- 93 -

Summary of Contents for HS3032

Page 1: ...Reference Manual Models HS3032 HS3128 and HS3248 WARNING This manual contains information on limitations regarding product use and function and information on the lim itations as to liability of the manufacturer Carefully read the entire manual ...

Page 2: ...g during a lightning storm l Never touch uninsulated telephone wires or terminals unless the telephone line has been disconnected at the net work interface l Position cables so that accidents can not occur Connected cables must not be subject to excessive mechanical strain l Use only the power supply provided with this equipment Use of unauthorized power supplies may cause damage l For direct plug...

Page 3: ...ing the system 51 Section 4 System operation 52 4 1 Arming and disarming 52 4 2 Partition vs global keypad 52 4 3 Labels 53 4 4 Annunciation 54 4 5 Keypad function keys 55 4 6 Language selection 57 4 7 Commands 58 4 8 Visual verification 71 Section 5 Programming 72 5 1 How to program 72 5 2 Programming methods 72 5 3 Programming descriptions 75 Section 6 Programming Worksheets 154 6 1 Label Progra...

Page 4: ...TEMENT 265 5 2 Innovation Scientific and Economic Development Canada ISED Statement 266 5 3 UL ULC Installations 266 5 4 Aux loading and battery selection 270 5 5 SIA False Alarm Reduction Installations Quick Reference 270 5 6 EUROPEAN EN50131 COMPLIANCE STATEMENT 272 5 7 UK Compliance Statement 274 Appendix 6 Wiring diagrams 276 6 1 HS3032 HS3128 and HS3248 UL ULC wiring diagram North America onl...

Page 5: ...pes and 15 programmable zone attributes l 8 or 16 separate keypads supported l 32 separate wireless keys supported l 72 or 1000 separate proximity tags supported Access codes l Up to 1002 access codes 1000 level 2 EN including one system master code level 2 EN In addition one installer code level 3 EN and one maintenance code are available Note EN50131 1 compliant systems using more than 100 acces...

Page 6: ...1 1 On board ethernet connection 1 1 1 PC link interface 1 1 1 USB connectors 2 2 2 PC Link 1 1 1 Expansion Zones 32 128 248 Low current PGMs 32 128 128 High current PGMs 4 16 16 Relay output PGMs 4 32 32 Partitions 4 8 8 Keypads 8 16 16 Users 72 1000 1000 Standard event buffer 500 1000 1000 Priority event buffer 2000 2000 2000 Alarm buffer 100 100 100 Arming buffer 100 100 100 Wireless device exp...

Page 7: ...D Keypad with Prox HS2LCDPRO 8 16 16 LCD Keypad with Prox and Host HS2LCDRFPROx 1 1 1 Touchscreen with Prox HS2TCHPRO BLK 8 16 16 Wire free Keypad with Prox HS2LCDWFPROx 8 16 16 Wire free Keypad Prox and Voice HS2LCDWFVPROx 8 16 16 For UL installations 2 repeaters must be installed for proper signal routing HSM3408 HSM2108 can be enrolled on the system at the same time but each take up 1 zone expa...

Page 8: ...LCDWFPROx UL HS2LCDWFVPROx UL Hardwired keypads with PG host HS2LCDRFPROx UL Hardwired keypads HS2LCDPRO UL Touchscreen keypad Note For ULC s559 Listed applications the HS2TCHPRO BLK touchscreen keypad is for supplementary use only HS2TCHPRO BLK UL 2 way wireless transceiver HSM2HOSTxUL 8 zone expander HSM2108UL 8 low current output expander HSM2208UL 8 zone expander HSM3408UL 1 A Power supply HSM...

Page 9: ...erature monitoring PGx862 UL PowerG wireless long range ceiling mount detector with temperature monitoring PGx872 UL PowerG wireless outdoor curtain PIR PGx902 UL PowerG wireless PIR motion detector with optional animal resistance PGx904 P UL PowerG wireless PIR motion detector with temperature monitoring PGx914 P UL PowerG wireless curtain PIR motion detector PGx924 UL PowerG wireless PIR motion ...

Page 10: ...nstalled on all enclosures including door opening protection and or removal from the mounting position Doors can be secured using screws or keylock Model HSC3010C hinged door made of 18 Ga steel painted white dimensions 372 mm x 412 mm x 114 mm weight 9 75 lb or 4 2 Kg Model HSC3010CR hinged door made of 18 Ga steel painted red dimensions 372 mm x 412 mm x 114 mm weight 10 0 lb or 4 5 Kg Model HSC...

Page 11: ... before applying AC and power up the system The alarm controller will not power up if only the battery is connected Step 7 enroll keypads and modules All keypads must be enrolled in order to operate on the system To enroll the first keypad see Enrolling the first keypad on page 46 To enroll optional keypads enter installer s programming section 902 000 For more information see Module Programming o...

Page 12: ...les l Tamper switch and bracket l Power supply including GND connection for HSC3010C HSC3010CR and HSC3030CAR enclosures see dia gram Note that the ground nut mounts from the back of the cabinet 5 Hang the enclosure on the top two screws again then fasten the tamper bracket to the wall 6 Install the two bottom screws Ensure that all four screws are securely tightened 7 Install the alarm controller...

Page 13: ...rm controller PCB power supply module and tamper bracket inside the HSC3020C enclosure Figure 2 3 HSC3020C enclosure 40 64cm 16in 18 44cm 7 26in 2 69cm 1 060 2 79cm 1 10in 35 38cm 13 93in 0 97cm 0 38in A A Tamper mounting location Note When power adapter model HS65WPSNA is not mounted inside the enclosure model HSC3010C or HSC3020C it must be attached to the mounting surface using appropriate scre...

Page 14: ...g location of the HSM3204CX HSM3350 power supply module and tamper bracket inside HSC3010C HSC3010CR HSC3030CAR and HSC3020 enclosures Figure 2 5 HSM3304CX HSM3350 mounted in HSC3010C HSC3010CR HSC3030CAR enclosures HSM3408 in HSC3010 enclosure The following diagram indicates the routing of power limited and non power limited wiring inside the enclosure Battery leads and AC cord are non power limi...

Page 15: ... mounting in HSC3020C enclosure The following diagram indicates the available mounting locations of the HSM3350 HSM3408 power supply module and tamper bracket inside the HSC3020C enclosure Figure 2 7 HSM3408 and HSM3350 modules in HSC3020C enclosure HSM3408 HSM3408 HSM3350 HSM3408 15 ...

Page 16: ...ions in HSC3010 enclosure The following diagram indicates all available mounting locations of the HSM2108 HSM2208 inside HSC3010C HSC3010CR HSC3030CAR and HSC3020 enclosures Figure 2 8 HSM2108 HSM2208 mounted in HSC3010C HSC3010CR HSC3030CAR enclosures 16 ...

Page 17: ...r limited All other wiring is power limited Figure 2 9 Panel wiring for HSC3010C For HSC3010C installations complete the following steps 1 If mounting the power supply inside the cabinet attach it as per figure 2 4 using supplied hardware Use cable ties to secure the DC wires to the enclosure IMPORTANT Minimum 1 4 inch 6 4 mm separation must be maintained at all points between battery AC wiring an...

Page 18: ...and guage DISTANCE GAUGE 2 meters 6 5ft 22AWG 3 meters 10ft 20AWG 4 meters 13ft 18AWG MICRO B PC LINK USB TYPE A This diagram shows routing of power limited and non power limited wiring inside the enclosure Battery leads and AC cord are non power limited All other wiring is Power limited 4Ah 7Ah 2 x 7Ah 17Ah Tamper switch and mounting bracket For HSC3020C installations complete the following steps...

Page 19: ...rd to snap in place Primary 120VAC 60Hz Class VI Secondary 18V DC 3 6A Power adapter module HS65WPSNA Note Do not connect Power adapter module to receptacle controlled by a switch 4Ah 7Ah 2 x 7Ah 17Ah Red Black Plastic grommet strip Not supplied recommmended Power supply mounting screws Cable tie required Tamper switch and mounting bracket Note Power supply may be mounted outside the cabinet Use t...

Page 20: ...itch Note Power adaptor module may be mounted outside the cabinet Use the following guide to determine sutiable distance and guage DISTANCE GAUGE 2 meters 6 5ft 22AWG 3 meters 10ft 20AWG 4 meters 13ft 18AWG This diagram shows routing of power limited and non power limited wiring inside the enclosure Battery leads and AC cord are non power limited All other wiring is Power limited STAND OFF PC BOAR...

Page 21: ...ard to snap in place Primary 120VAC 60Hz Class VI Secondary 18V DC 3 6A Power adapter module HS65WPSNA Note Do not connect Power adapter module to receptacle controlled by a switch 4Ah 7Ah 2 x 7Ah 17Ah Red Black Plastic grommet strip Not supplied recommmended Power supply mounting screws Cable tie required Tamper switch and mounting bracket Note Power supply may be mounted outside the cabinet Use ...

Page 22: ...nap in place Cable tie required Primary 120V AC 60Hz Class VI Secondary 18V DC 3 6A Power adaptor module HS65WPSNA Note Do not connect power adaptor module to a receptacle controlled by a switch Grommet strip Not supplied Part 57000933 Power supply mounting screws Cable tie required Note Power adaptor module may be mounted outside the cabinet Use the following guide to determine sutiable distance ...

Page 23: ...lowing steps 1 Route the AC line through the opening on the bottom of the cabinet and secure using cable tie as shown in figure 2 14 2 Connect AC wires to the fuse block as shown Note Position cable ties over cable insulation not directly on the exposed AC wires WARNING Incorrect connections may result in PTC failure or improper operation Inspect wiring and ensure connections are correct before ap...

Page 24: ...ommunicator case tamper switch battery and AC must be wired during installation For HSC3020CP plastic enclosure installations complete the following steps 1 Route the AC line in through the opening on the bottom of the cabinet and secure using cable tie as shown in figure 2 15 2 Connect AC wires to the fuse block as shown Note Position cable ties over cable insulation not directly on the exposed A...

Page 25: ...CP wiring diagram Figure 2 17 Panel wiring for HSC3020CP enclosure This diagram shows routing of power limited and non power limited wiring inside the enclosure Battery leads and AC cord are non power limited All other wiring is power limited 25 ...

Page 26: ...ational wiring diagram This diagram shows routing of power limited and non power limited wiring inside the enclosure Battery leads and AC cord are non power limited All other wiring is power limited Figure 2 18 HSM3350 wiring for HSC3020CP enclosure 26 ...

Page 27: ...munication between the alarm controller and connected modules Each module has four Corbus terminals that must be connected to the Corbus PGM1 to PGM4 Programmable output terminals Use to activate devices such as LEDs relays buzzers etc PGM1 PGM4 100 mA PGM2 300 mA or can be configured for use as a 2 wire smoke detector interface max loop current 100 mA PGM3 300 mA negative trigger or 1 A positive ...

Page 28: ... Device Output Rating 12 V DC HS3032 HS3128 HS3248 AUX Corbus 2 A Subtract the listed rating for each keypad expansion module and accessory connected to AUX or Corbus At least 100 mA must be reserved for the Corbus BELL 700 mA continuous rating 2 A short term Available only with standby battery connected DO NOT exceed the 700 mA load for UL ULC or EN certified applications HSM3350 AUX1 AUX2 3 A Su...

Page 29: ...period longer than 5 minutes an overcurrent trouble is generated When the current goes below a 2 0 A threshold the trouble restores Do not exceed 2 0 A combined between AUX and Corbus Note Total current does not include bell current or battery charging Line loss Voltage loss through wire resistance must be considered for all installations To ensure proper operation at least 12 5 VDC must be applie...

Page 30: ...the wire used Table 2 3 Wire capacitance Wire Capacitance per 1000 ft 300 m Total Corbus Wire Length 15 nF 5300 ft 1616 m 20 nF 4000 ft 1220 m 25 nF 3200 ft 976 m 30 nF 2666 ft 810 m 35 nF 2280 ft 693 m 40 nF 2000 ft 608 m 2 4 Installing modules Remove all power from the system while connecting modules to the alarm controller Zone expanders The main alarm controller has connection terminals for zo...

Page 31: ...ain alarm controller has a 3 pin analog audio link interface to connect the module Figure 2 22 HSM2955 2 way audio module Output expander The HSM2208 module is used to add up to 8 low current programmable outputs to the alarm system The 4 wire Corbus connection is used by the panel to communicate with the module Connect the RED BLK YEL and GRN terminals to the Corbus terminals on the alarm panel B...

Page 32: ...rbus connection provides communication between the module and alarm panel Connect the RED BLK YEL and GRN terminals to the Corbus terminals on the alarm controller If O1 is not used connect to Aux with a 1 K resistor Board current draw 35 mA Figure 2 25 HSM2300 2204 power supply wiring AUX TO EXPANSION MODULE KEYBUS CONNECTION TO CONTROL PANEL RED BLK YEL GRN RED BLK YEL GRN Battery standby capaci...

Page 33: ...per contact Connect to tamper switch installed in the cabinet for door cover removal or removing from mounting location tamper detection Primary input UL ULC applications 120 VAC 60 Hz 1 7 A cord connected CE EN50131 applications 230 VAC 50 Hz 1 7 A hardwired AUX output ratings UL ULC applications 10 8 VDC 12 5 VDC 3 A max EN50131 applications 10 Vdc 14 Vdc 3 A max Supervised CORBUS connects to th...

Page 34: ...e barrier kit hardwired connection to AC mains Primary Input 120 VAC 50 Hz 1 7 A Max Output 18 VDC 3 6 A Max Model HS65WPS is required for CE EN50131 certified applications It shall be installed inside the metal cabinet model HSC3020C hardwired connections to AC mains see wiring diagram below Primary Input 230 VAC 60 Hz 1 7 A Max Output 18VDC 3 6A Max WARNING High Voltage Disconnect AC power lines...

Page 35: ... HSM2955 wiring For wiring information refer to HSM2955 Installation manual 29010198xxx Zone wiring Power down the alarm controller and complete all zone wiring Zones can be wired to supervise normally open devices e g smoke detectors or normally closed devices e g door con tacts The alarm panel can also be programmed for single end of line double end of line and triple end of line resistors Zone ...

Page 36: ...oop open Violated Single end of Line SEOL resistor When SEOL resistors are installed at the end of a zone loop the alarm panel detects if the circuit is secure open or shorted The SEOL resistor must be installed at the end of the loop for proper supervision To enable SEOL supervision program section 013 options 1 and 2 to OFF To configure SEOL supervision per zone use programming section 002 bit 1...

Page 37: ...o ON To configure DEOL supervision per zone use pro gramming section 002 bit 11 Figure 2 31 DEOL wiring Note If the DEOL supervision option is enabled all hardwired zones must be wired for DEOL resistors except for Fire and 24 Hour Supervisory zones Do not use DEOL resistors for Fire zones or 24 Hour Supervisory zones Note Do not wire Fire zones to keypad zone terminals if the DEOL supervision opt...

Page 38: ...able in section 004 PGM wiring Min max operating voltages for devices sensors and modules is 9 8 V DC 14 V DC PGMs switch to ground when activated from the alarm controller Connect the positive side of the device to the AUX ter minal and the negative side to a PGM terminal PGM 1 and 4 supply up to 100 mA PGM 2 and 3 supply up to 300 mA A relay is required for current levels that exceed the maximum...

Page 39: ...Bell output is supervised and power limited by 2 A hardware protection If unused connect a 1000 Ω resistor across Bell and Bell to prevent the panel from displaying a trouble See Troubleshooting on page 59 Telephone line wiring Wire the telephone connection terminals TIP Ring T 1 R 1 to an RJ 31x connector as indicated in the following diagram For connection of multiple devices to the telephone li...

Page 40: ...RT FSA 410xST FSA 410xRS Current ratings for DSC FSA 410 Series 25mA 90mA Fire zone wiring 2 wire smoke detectors If PGM 2 is programmed for 2 wire smoke detector connection the detectors must be wired according to the following dia gram Figure 2 37 2 wire smoke detector wiring Note Additional 2 wire smoke detectors must be connected in parallel as shown above The maximum number of smoke detectors...

Page 41: ... CO detector models can be used with PowerSeries Pro alarm controllers l Potter Model CO 12 24 UL File E321434 l Quantum Model 12 24SIR UL File E186246 l NAPCO Model FW CO12 or FW CO1224 UL File E306780 l System Sensor Model CO1224 UL File E307195 Note For multiple unit connections the leads between CO detectors must be broken The power supervision relay must be powered from the last detector in t...

Page 42: ... NC C NO ANY Z SEOL ZONE TYPE 41 AUX Earth ground wiring Using the supplied insulated green wire connect the earth ground terminal on the HS65WPSx power adapter to the earth ground screw and nut assembly as shown in the diagram The earth ground screw and nut assembly must be mounted to the cabinet to one of the designated holes marked with the earth ground symbol Figure 2 39 Earth ground installat...

Page 43: ...0131 Grade 3 l 36 Hours NFA2P 2 shield or 60 hours NFA2P 3 shield The battery size is measured in amp hours Ah The current values in the table denote the maximum current draw permitted to achieve the desired standby time with the listed battery types Table 2 13 Standby battery guide Battery size Desired standby time 4 h 12 h 24 h 30 h 36 h 60 h 4 Ah 700 mA 7 Ah 1200 mA 500 ma 250 mA 14 Ah 2x7 2000...

Page 44: ...keypads have certain basic functionality in common Special keys Scroll symbols on keypads with LCD displays indicate that options can be viewed by pressing the scroll keys These keys can also be used to position the cursor The key is similar in function to the Enter key on a personal computer It is generally used to accept the existing pro gramming option It is also the first key entry for command...

Page 45: ...the particular programming section being accessed Entering letters manually system labels 1 In Installer Programming enter the section requiring text input 2 Use the arrow keys to move the cursor to a blank space or existing character 3 Press the number key corresponding to the appropriate letter Each number button accesses three letters and a number The first press of the number key displays the ...

Page 46: ...maximum wire run length l the module does not have enough power Removing modules Enrolled modules can be deleted from the system via programming section 902 For instructions see 902 Add Remove Modules on page 149 Enroll wireless devices Wireless devices are enrolled via the wireless transceiver module and Installer Programming section 804 000 See Com patible devices on page 8 for a list of support...

Page 47: ...er activation deactivation of the output depends on the partition that ini tiated the alarm sequence Only the partition that originated the alarm can deactivate the bell output Global zones such as smoke detectors shared by multiple partitions can deactivate the siren on all partitions the zone is assigned to Multiple siren output operation When multiple sirens are used in the installation they ca...

Page 48: ... arrow keys to scroll through available partitions Press to select The keypad is temporarily loaned to another partition If the keypad is inactive for more than 30 seconds it reverts to its assigned partition Global zones If a zone is added to more than one partition it becomes a global zone A global zone is only armed when all assigned par titions are armed and is disarmed when any assigned parti...

Page 49: ...tself can have their programming returned to factory default settings Hard ware is defaulted via the following Installer Programming sections l 991 Default Keypads l 000 Default all keypad programming l 001 016 Default keypads 1 8 l 996 Default wireless receiver l 998 Default HSM2955 l 999 Default system See Defaults on page 152 for more information Default all labels Use programming section 000 9...

Page 50: ...0 option 02 communication path see 300 Panel Receiver Communication Paths on page 115 380 option 01 communications enabled disabled see 380 Communicator Option 1 on page 125 383 option 03 ethernet communications enabled disabled 383 option 04 cellular communications enabled disabled 308 351 356 reporting codes see 351 Alternate Communicator 1 401 option 7 DLS access see 401 System Test Events Comm...

Page 51: ...aller to test the operation of each detector by tripping zones causing an actual alarm Enter section 901 to initiate a walk test When a zone is tripped all system sirens emit a tone to indicate that the zone is working correctly After 15 minutes without zone activity the walk test terminates automatically To manually exit walk test mode enter 901 again Viewing the event buffer The event buffer con...

Page 52: ...ds behave as follows l Display the armed state of the partition l Display open zones if the zone belongs to the partition the keypad is assigned to l Display bypassed zones and allow zone bypassing or creating bypass groups of zones assigned to the keypad par tition l Display system troubles system low battery system component faults tampers l Display alarms in memory that occurred on the partitio...

Page 53: ...d Library or by downloading uploading using DLS See 000 Label Programming on page 75 System label This feature is used to program a custom label for the security system This label is used in the event buffer when system events occur The maximum label size is 14 ASCII characters See 100 System label on page 77for programming details Zone labels Customized labels can be created for each zone on the ...

Page 54: ...VPROx keypads only The above door chime sounds are programmable in section 861 876 subsections 101 228 Chime is enabled disabled on a partition using the 4 command Temperature display Indoor and outdoor temperature can be displayed on system keypads if configured in keypad programming section 861 876 023 option 7 and sections 041 042 Temperature is detected using wireless temperature sensors insta...

Page 55: ...ed for 2 seconds in order to activate the function Function key definitions This section provides detailed descriptions of each programmable function key option 00 Null Function Key This option deactivates the function key The key does not perform any function when pressed 02 Instant Stay Arm This feature is similar to the Stay Arm function key except that no exit delay is applied and the system a...

Page 56: ...tion is equivalent to entering 0 at the keypad while the partition is armed If quick exit is not enabled on the system or if the system is disarmed pressing this key causes an error tone An access code is not required to use this key See 015 System Option 3 on page 103 for more information 17 Arm Interior This key removes or enables automatic bypass on all Stay Away zones equivalent to pressing 1 ...

Page 57: ...s function key requires a code if section 023 option 5 is enabled 40 Alarm Memory This function puts the keypad in alarm memory display mode and is equivalent to pressing 3 This function only works while the system is disarmed This function key requires a code if section 023 option 6 is enabled 61 68 Partition 1 to 8 Select This function selects partition 1 8 when the assigned key is pressed Press...

Page 58: ...owed The zone attribute for zone bypassing must be enabled see section 002 Zone Attributes Option 04 Holdup zones should not be part of bypass groups A zone that is manually bypassed via 1 will bypass the alarm fault and tamper conditions when DEOL is used If a 24 hour zone is bypassed ensure that the zone is restored or disabled before removing the bypass When the alarm system is disarmed Users c...

Page 59: ...with access to the appropriate partition must be used Bypass Recall Press while in this menu to bypass the same group of zones that were bypassed the last time the partition was armed Clear Bypasses Press to clear all bypasses Shortcuts from the 1 base menu 991 bypass group 995 program group 1 998 bypass open zones 999 bypass recall 000 clear group When the alarm system is armed When the system is...

Page 60: ...ailure System Failure detected with internal power unit 08 Failure detected with internal power unit HSM3204CX Corbus Repeater 09 Failure detected with internal power unit HSM3350 3 A Power Supply 10 Overcurrent Trouble If the total current of the panel internal components and all outputs exceeds a threshold of 2 1 A for a period longer than 5 minutes an overcurrent trouble is generated When the c...

Page 61: ...n AC or DC input power trouble 05 HSM2300 01 04 AC An HSM2300 has an AC or DC input power trouble 06 HSM2204 01 04 AC An HSM2204 has an AC or DC input power trouble 07 Panel AC The alarm controller has an AC failure condition 08 HSM3204CX AC A corbus repeater has an AC or DC input power trouble 09 HSM3350 AC The 3A power supply has an AC or DC input power trouble Trouble 05 Device Faults Note Fire...

Page 62: ...nding 09 HSM2955 is not responding 11 HSM3408 is not responding 12 HSM3204CX is not responding 13 HSM3350 is not responding Trouble 10 Module Tamper 01 HSM2HOSTx Tamper 02 Keypad 01 16 Tamper 04 HSM2108 01 30 Tamper 05 HSM2300 01 04 Tamper 06 HSM2204 01 04 Tamper 08 HSM2208 01 16 Tamper 09 HSM2955 Tamper 10 Alt Comm Tamper 11 HSM3408 Tamper 12 HSM3204CX Tamper 13 HSM3350 Tamper Trouble 11 Communic...

Page 63: ...firmware e g 220 02 Interactive partition The number of partitions configured is not supported by Alarm com firmware e g 8 IMPORTANT Ensure you have the following information available before contacting Customer Support l Alarm controller type and version e g HS3032 1 0 Note Version number can be accessed by entering Installer Code 900 on any keypad This information is also located on a sticker on...

Page 64: ... is on The Installer and Master codes are system codes They can be changed but not deleted The other codes are user defined and can be added or deleted as necessary By default access codes have the same partition and attribute programming as the code used to program them Access codes are either 4 6 or 8 digits in length depending on the setting of programming section 041 Duplicate codes are not va...

Page 65: ...hen used to perform any function on the system Duress codes cannot be used to access 5 6 or 8 menus Duress codes are created by the master user or supervisor users Note Section 019 option 6 must be on to select the Duress Codes attribute One Time Use Code A one time use code is a user code with the One Time User attribute enabled This access code enables the user to arm the alarm system an unlimit...

Page 66: ... details Do not apply this code to users with wireless keys assigned Using an LCD keypad 1 Press 5 Master Code 2 Use the scroll keys to choose a user 02 1000 then press to select 3 Scroll to Press for User Options then press to select 4 Scroll to a user attribute and press to toggle it on or off Add user labels Custom labels can be programmed for each user to more easily identify them on the alarm...

Page 67: ...r for a proximity tag or wireless key to be operational 6 user functions The 6 command provides access to functions described below If section 023 option 8 is on any user code can access this menu If option 7 is off only the master or supervisor code can access this menu Event Buffer Menu 6 Master Code Event Buffer Keypad 6 Master Code This option is used to view system events stored in the event ...

Page 68: ...ive bell Note The Auto Arm Cancellation reporting code is also transmitted if arming is inhibited by one of the following l AC DC Inhibit Arm l Latching System Tampers l Zone Expander Supervisory Fault Other programming options that may affect this function See 151 158 Partition Auto Arm Disarm on page 113 See 014 System Option 2 on page 102 Enable DLS Allow System Service Menu 6 Master Code Syste...

Page 69: ...nabled A separate time can be programmed for each day of the week Valid data entries are 00 00 23 59 99 99 disables the late to open feature for the selected day Select a day of the week by scrolling while in the Late to Open menu or by using keys 1 7 to select Sunday to Saturday respectively Brightness Control Menu 6 Master Code Brightness Control Keypad 6 Master Code 12 This function is used to ...

Page 70: ...te If no command outputs are programmed this function is not available Other programming options that may affect this user function See 121 124 Command Outputs 1 4 on page 89 8 installer programming Use this option to place the alarm system in Installer Programming mode Installer Programming is used to manually pro gram alarm panel and module options An installer s code is required to access this ...

Page 71: ...ny additional activity on another zone triggers the associated alarm or delay sequence 4 8 Visual verification This feature enables the central station operator to view captured images of the premises in the event of an alarm event Combination camera motion detectors can be installed throughout the premises to provide visual verification coverage The microphone on the camera PIR can be disabled Vi...

Page 72: ...ection options See Template programming tables on page 258 for programming information Perform template programming after completing the hardware installation Ensure you have the information listed below available Record this information in the programming worksheets for future reference l Monitoring station telephone number provided by the alarm monitoring service l Monitoring station account cod...

Page 73: ... code details 9 Template Programming will automatically exit after the installer s code has been programmed Note EN50131 1 compliant systems using 1000 access codes shall set the access code to 8 digits section 041 option 02 DLS programming DLS programming involves downloading custom programming using DLS software and a computer This can be done loc ally or by remote Note For UL listed systems an ...

Page 74: ...he Ready light illuminates and the information programmed in the section is displayed For programming sections with toggle options press the corresponding number on the keypad to turn the option on or off The display changes accordingly Sections requiring data input such as phone numbers display the full data in fields up to 32 characters long To input data use the scroll keys to select a characte...

Page 75: ...s locally or download upload using DLS Local label programming is done via a system keypad as described below 000 Language selection To select a language 1 Enter Installer Programming 8 Installer Code 2 Enter programming section 000 000 3 Key in the 2 digit number corresponding to the language required See the following table Table 5 3 Language codes 01 English 11 Swedish 22 Bulgarian 02 Spanish 1...

Page 76: ... the Word Library a collection of words commonly used when programming labels See below for details ASCII ENTRY Used to access uncommon characters or as a primary method for programming labels 255 character entries are available Use the keys to scroll through the characters or enter a 3 digit number from 000 255 Press to select a character See ASCII characters on page 264 for available ASCII chara...

Page 77: ...abel for the security system This label is used in the event buffer when system events occur The maximum label size is 14 x 1 characters 101 108 Partition 1 8 labels Use this section to program a name for each partition for display on partition keypads and event messages The maximum label size is 14 x 2 characters See Programming on page 72 for specific instructions on how to program labels 201 20...

Page 78: ...sirens 1 16 821 001 008 Repeater labels Use this section to create custom labels for wireless repeaters on the system Select 001 008 for repeater 1 8 999 Installer Code 999 Default labels This section is used to return all labels to factory settings Installer code is required to verify deletion Zone setup The following section describes zone programming options To program a zone type first enter s...

Page 79: ...er or fault of this zone type causes a fire trouble to log and transmit Note The supervision options NC SEOL DEOL TEOL do not affect the functionality of this zone The restored state of this zone type is 5 6k the alarm state is short and the trouble state is open 009 Instant Stay Away Commonly assigned to interior motion sensors This zone type is bypassed when armed in Stay mode but functions like...

Page 80: ...rm sounds If the same zone is activated again up to 60 seconds after the delay expires the alarm is triggered immediately If the same zone is activated after 60 seconds the entire sequence begins again If a second fire zone is violated during the auto verify sequence both zones a fire alarm is immediately triggered Wireless smoke detectors When the zone is activated a 40 second delay begins The al...

Page 81: ... above a programmed threshold set in section 804 xxx 019 020 Instant alarm when activated audible alarm at default This zone type gen erates an alarm when the system is armed or disarmed Note This zone type cannot be used on hardwired zones The temperature threshold includes a 3 C 5 6 F difference between a given state and its restored condition For example an alarm at 6 C is restored at 3 C High ...

Page 82: ...partition and silences alarms Tampers or faults do not disarm the zone Note Do not use as a global zone 069 Maintained Keyswitch Disarm Used with a maintained keyswitch Activating this zone disarms the partition Tampers or faults on this zone do not disarm the partition 071 Doorbell Zone This zone type sounds a chime through keypads on the partition when activated No alarms are generated Various c...

Page 83: ...winger shutdown if programmed OFF Swinger shutdown is disabled All alarms are transmitted 07 Transmission Delay ON Reporting of zone alarms is delayed for the programmed time in section 377 See 002 Communication Delays on page 124 If a valid access code is entered within this time no alarm signal is communicated OFF When an alarm occurs the reporting code is transmitted immediately 08 Burglary Ver...

Page 84: ...EOL options in 3 digit format For example to program the value of 0 5 kΩ enter 005 001 Single EOL Alarm Default value 5 6 kΩ Programmable range 0 5 kΩ to 28 kΩ 005 to 280 002 Double EOL Alarm Default value 5 6 kΩ Programmable range 0 5 kΩ to 15 kΩ 005 150 Tamper Default value 5 6 kΩ Programmable range 0 5 kΩ to 15 kΩ 005 150 003 Triple EOL Alarm Default value 5 6 kΩ Programmable range 0 5 kΩ to 7 ...

Page 85: ... gains an average of 11 seconds per day Program the alarm controller to adjust the clock by 71 seconds for the last minute of each day This slows down the alarm controller s clock by 11 seconds correcting the problem If the Auto arm time is set for 23 59 any change to the Clock Adjust option will directly affect the Auto arm pre alert time 001 008 Partition 1 8 Timers The following timers can be a...

Page 86: ...ode cannot change the master code or any other level 2 codes 002 Master Code This code is used by the master user a person designated to perform operational tasks beyond those of the standard user The master code provides access to functionality in the 5 and 6 menus 003 Maintenance Code This code is usually assigned temporarily to maintenance personnel who must deactivate the alarm to enter the pr...

Page 87: ...8 output expander HSM3204CX and HSM2204 High Current output modules PGM attributes are defined in section 010 PGM Attributes on page 92 001 324 Select PGM 100 Null PGM This option deactivates the PGM output 101 Burglary and Fire Bell Follower This PGM output follows l Fire pre alerts l Temporal three fire signal if enabled l All audible burglary and fire alarms by partition l Bell cut off time l B...

Page 88: ...for the entry and exit times plus 2 minutes This option is typically used to activ ate a courtesy light near the exit door for the duration of the entry exit times 111 Keypad Buzzer Follow PGM output activates with the keypad buzzer when triggered by the events below The PGM output remains active for the duration of the keypad buzzer l 24 hour supervisory buzzer zone alarm l Auto arm and no activi...

Page 89: ... deactivates If holdup alarms occur on multiple partitions an access code must be entered at each partition before the output deactivates Note Not for use with UL ULC listed installations 134 24 Hour Silent Input PGM 2 With this input the keypad does not indicate an alarm the siren remains silent and the signal is sent to the central station This input does not follow swinger shutdown A 2 2KΩ EOL ...

Page 90: ...mmed in section 010 differ from the standard selection of attributes nor mally programmed Note When this PGM is configured to provide Opening Closing status the PGM must be programmed as a timed output not latching 155 System Trouble This output can be programmed to activate when any of the following trouble conditions are present l Service Required l Loss of Clock l DC Trouble l Bus Voltage l AC ...

Page 91: ...tag is presented Assign this output to a user by entering a user number from 0002 to 1000 To enable this attribute for all proximity tags enter 000 in PGM Configuration 011 See 007 008 PGM Configuration on page 86 166 Partition Prox Used This output activates when a proximity tag is presented at a system keypad equipped with a proximity tag reader including global keypads The proximity tag must be...

Page 92: ...s The following options are used to program the operating characteristics of the main bell and PGM outputs 000 Main Bell Mask This programming section is used to configure the types of audible alarms that trigger the main bell output on the alarm con troller All options are selected by default Fire Alarm ON Fire alarm F key Fire zones activates the main siren OFF Fire alarm does not activate the m...

Page 93: ...t Inverted ON deactivated during normal operation Activated when triggered OFF active during normal operation Deactivated when triggered 03 Access Code Required No Code Required ON Access code required for activation OFF No access code required for activation 107 External Siren 01 True Output Inverted ON deactivated during normal operation Activated when triggered OFF active during normal operatio...

Page 94: ...al operation Activated when triggered OFF active during normal operation Deactivated when triggered 117 Armed Stay Mode 01 True Output Inverted ON deactivated during normal operation Activated when triggered OFF active during normal operation Deactivated when triggered 120 Away Armed with No Zone Bypasses Status 01 True Output Inverted ON deactivated during normal operation activated when triggere...

Page 95: ...n deactivated when triggered 02 Timed Output Latched Output ON output remains active until the PGM output timer expires OFF output remains active until an access code has been entered 04 Fire Alarm ON activates with fire alarm F key fire zones 2 wire smoke OFF does not activate with fire alarm 05 Panic Alarm ON activates with panic alarm P key panic zones OFF does not activate with panic alarm 06 ...

Page 96: ...required trouble condition 05 Loss of Clock ON activates on loss of clock trouble condition OFF does not activate on loss of clock trouble condition 06 DC Trouble ON activates if a panel low or no battery trouble is detected or if an HSM2204 2300 1 4 low or no battery trouble is detected OFF does not activate on DC Trouble condition 07 Bus Voltage ON activates when a system module has measured a l...

Page 97: ...le Supervisory ON activates if any of the following module supervisory troubles is detected l HSM2HOST l keypad 01 16 l zone expander 01 30 l HSM2204 1 4 l HSM2300 1 4 l HSM2208 01 16 l HSM3204CX l HSM3408 l HSM3350 OFF does not activate if a module supervisory trouble is detected 14 Module Tamper ON activates if any of the following module tamper conditions is present l HSM2HOST l Keypad 01 16 l ...

Page 98: ...l an access code has been entered 04 Fire Alarm ON activates with fire alarm F key fire zones 2 wire smoke OFF does not activate with fire alarm 05 Panic Alarm ON activates on panic alarm audible or silent OFF does not activate on panic alarm 06 Burglary Alarm ON activates on burglary alarm OFF does not activate on burglary alarm 07 Medical Alarm ON activates on medical alarm OFF does not activate...

Page 99: ... output remains active until an access code is entered or certain criteria have been met depending on the PGM type OFF output remains active until the PGM output timer expires 09 Battery Low ON activates when a low battery trouble occurs OFF does not activate when a low battery trouble occurs 10 Battery Absent ON activates when a battery absent trouble occurs OFF does not activate when a battery a...

Page 100: ...Output Latching Follow Alarm PGM Output OFF OFF OFF ON upon zone opening including tamper and fault OFF upon zone closing OFF OFF ON ON upon zone alarm OFF upon bell cut off or alarm silenced OFF ON OFF ON upon zone opening OFF upon valid code OFF ON ON ON upon zone alarm OFF upon valid code ON OFF OFF ON upon zone opening OFF upon PGM timer expires ON OFF ON ON upon zone alarm OFF upon PGM timer ...

Page 101: ...is programming option determines the number of invalid access code entries allowed via SMS or DLS before remote access is locked out for the programmed duration see below If the number of invalid attempts is not reached within one hour or if a valid access code is entered through SMS or DLS the counter is reset to 0 The valid entries are 003 to 255 attempts Default is 6 attempts The number of inva...

Page 102: ...improper exit was made If the alarm system is disarmed within the entry delay period no signal is sent OFF The entry delay warning is sounded only through the keypad 7 Event Buffer Follows Swinger ON Once an event reaches its swinger shutdown limit programmed in 377 Communication Variables on page 123 it will no longer log events to the event buffer until the swinger shutdown is reset This avoids ...

Page 103: ...s generated the keypad buzzer and the siren are silent but the alarm is still transmitted if programmed Note Fire Medical and Panic key transmissions follow the partition 1 alarm restore call direction options Fire Medical and Panic key The Fire Medical Panic keys operate even if keypad blanking and keypad lockout are active 3 Quick Exit ON When the system is armed users may enter the 0 command to...

Page 104: ...when the keypad is blank unless the function key is programmed to require an access code Keypad Blanking While Armed overrides this feature When a partition is armed and in alarm entering a code to remove blanking silences the alarm and disarms the system OFF The keypad lights remain ON at all times 4 Keypad Blanking Requires Code ON A valid access code must be entered before a blanked keypad can ...

Page 105: ...te to Close ON Provides an audible warning if the alarm system has not been armed by a programmed time of day but does not arm the alarm system The alarm system communicates and logs a Late to Close event at the end of the Auto arm Postpone pre alert for each partition OFF The alarm system will neither communicate nor log a Late to Close event at the time programmed for Auto arm for each partition...

Page 106: ...GM l 120 Away Armed with No Zone Bypass Status l 129 Partition Status Alarm Memory OFF PGMs are activated at the beginning of exit delay This applies to PGMs with one of the armed status attributes listed above 4 Auto Bypass Report ON All Night or Stay Away type zones that are auto bypassed when arming in Night or Stay mode log and report Zone Bypass When disarming all auto bypassed Night or Stay ...

Page 107: ...Only a police code sequential detection alarm requires a remote reset once the partition has been disarmed OFF Any burglary alarm requires a remote reset once the partition has been disarmed 020 System Option 8 1 Access Code Entry During Entry Delay ON During entry delay the alarm system can only be disarmed using a keyswitch or proximity tag When the siren is active an access code can still be us...

Page 108: ...ayed on the keypad This feature applies to tampers and faults in both armed and disarmed states and does not apply to module tampers system supervisories zone expander alarms or PGM 2 input alarms Note If Engineer s Reset is triggered during exit delay the system still arms Troubles cannot be overridden while Engin eer s Reset is enabled OFF The system does not require Engineer s Reset or to be pl...

Page 109: ...y with EN50131 1 2006 When the system enters blanking mode any PGMs programmed as Armed Status Ready Status Away Armed Status or Stay Armed Status will de activate If blanking is cleared by pressing a key or entering an access code depending on how the panel is configured these PGMs must re activate if they would have normally been ON if blanking was disabled OFF When the system enters blanking mo...

Page 110: ...tripped partition keypads flash the ready LED in the disarmed state instead of illuminating it steadily If a non force arm capable zone is tripped the ready LED turns off OFF If a force arm capable zone is tripped the Ready LED is illuminated steadily If a non force arm capable zone is tripped the Ready LED turns off 2 Access Code Required for ON When using the Temperature Display Menu command an ...

Page 111: ... trigger Tampers Inhibit Arming l Faults on the zones modules l Tampers on the zones modules l Bell circuit trouble l Communications fault troubles TLM FTC Radio Sim card failure ethernet trouble communicator fault l Warm start troubles Tampers must be restored through Installer Programming before the system can be armed including no activity and key switch arming Reset Required displays on the ke...

Page 112: ...rt Indication ON Warm Start trouble is logged and indicated in the 2 Troubles Menu OFF Warm Start trouble is a log only event 5 I D Tone ON After the telephone number is dialed the alarm system emits a tone as specified by I D Tone Frequency option for 500ms every two seconds to indicate that a digital equipment call is in progress OFF I D tone is disabled 6 Tone Generated 2100Hz ON 2100 Hz I D to...

Page 113: ...ification zone attribute enabled contribute to the gen eration of a confirmed Holdup alarm in conjunction with this counter and the holdup verification timer Burglary Verification Selection Use this section to select one of the following burglary verification timer modes Mode Description 001 Police Code The burglary verification timer operates in minutes 002 Cross Zoning The burglary verification ...

Page 114: ...oned multiple times 006 Partition No Activity Arming Timer Use this section to program the duration of the No Activity timer If this timer expires and no zones have been activated the partition arms in Away mode exit delay will not sound When the timer expires keypad buzzers activate for the time pro grammed in No Activity Arming Pre Alert see below The timer restarts when a delay type zone is res...

Page 115: ...ations between the alarm system and the central station Paths can be established through either the alarm system s on board Public Switched Telephone Network PSTN con nection through the on board Ethernet or through the optional cellular communicator Paths to four receivers can be programmed using sections 001 004 The communications path for each receiver is defined by selecting one of the followi...

Page 116: ...ing cancel is typically 70 in most areas Dialing this string before a phone number disables call waiting for the duration of the call When this section is programmed and Call Waiting Cancel Options is ON see 382 Communicator Option 3 on page 127 the alarm system dials this string before the phone number This is only done on the first dialing attempt for each phone num ber This is a 6 digit field F...

Page 117: ...dow The central station acknowledges can cellation by providing a keypad ringback 002 Miscellaneous Alarm 2 1 Holdup Verified Sent when the configured Holdup verified conditions have been met Note Not for use with UL ULC listed installations 011 Priority Alarms 1 The reporting codes in this section are sent to the Alarm Restore call direction group and apply to all system keypads 1 2 Keypad Fire A...

Page 118: ...s transmitted when an exit error occurs and entry delay expires before the system is disarmed The Alarms and Restores call direction group is used for this reporting code If the delay zone that caused the exit error has cross zoning enabled the exit fault and zone alarm transmits if a second zone is not tripped The local alarm sequence follows cross zoning rules The exit error is transmitted with ...

Page 119: ... are restored The following events cause RF jam troubles l Wireless repeater jamming l RF jam 3 4 Fire Trouble Restore Sent when a low sensitivity tamper or internal fault condition restore is detected on a wireless smoke detector or supervisory fault with a hardwired smoke detector 5 Cold Start Sent when power is restored to the alarm system after total power failure The code is sent after 2 minu...

Page 120: ... disconnected trouble occurs or is restored on a wireless temperature detector 321 Receiver Events 2 4 6 8 Receiver 1 4 FTC Restore Sent when the panel detects an FTC trouble 331 Module Events 1 1 2 Module AC Trouble Restore This reporting code is transmitted when a module s AC supply fails or has been restored A programmable delay applies to both the trouble and the restore This reporting code is...

Page 121: ...ouble Restore 7 8 Receiver 4 Trouble Restore 355 Alternate Communicator 5 Receiver 1 to 4 Supervision Failure and Restore Sent when the alternate communicator detects a supervision trouble for the Ethernet receiver 1 2 or the GPRS receiver 3 4 1 2 Receiver 1 Supervision Failure Restore 3 4 Receiver 2 Supervision Failure Restore 5 6 Receiver 3 Supervision Failure Restore 7 8 Receiver 4 Supervision ...

Page 122: ...sent to multiple receivers 001 Maintenance Events Restores all troubles except tampers These options control which receiver paths are enabled for maintenance events To assign a maintenance event to a receiver select from the following list 01 Receiver 1 02 Receiver 2 03 Receiver 3 04 Receiver 4 002 Test Transmissions These options control which receiver paths are enabled for test transmission even...

Page 123: ...1 8 Tamper and Restore event reporting codes To assign an event to a receiver select one of the following options 01 Receiver 1 02 Receiver 2 03 Receiver 3 04 Receiver 4 003 Openings Closing These options control which receiver paths are enabled for Partition 1 8 Opening and Closing event reporting codes To assign an event to a receiver select one of the following options 01 Receiver 1 02 Receiver...

Page 124: ...not exceed 45 seconds AC Failure Communication Delay minutes or hours This value determines the delay before an AC failure or AC restore is reported The AC failure or restore is still displayed immediately Valid entries are from 000 to 255 minutes hours max 180 minutes for UL commercial installations Selection of minutes or hours for the delay is set in section 382 Communicator Option 3 on page 12...

Page 125: ...icator waits for a valid initial handshake from the receiver after dialing the programmed telephone number Valid entries are 001 to 255 seconds UL Note Maximum 45 seconds for UL installations 015 IP Wait for Ack This option is used to program the length of time the communicator waits for an acknowledge after transmitting via IP GS Valid entries are 001 to 255 Default is 60 seconds 016 IP Cellular ...

Page 126: ...xt backup receiver in the sequence and makes up to 5 more attempts This continues until communication is successful or until all backup receivers fail at which point an FTC trouble for the primary number is logged 7 Reduced Dialing Attempts ON If a TLM trouble is present The alarm system immediately attempts to call the backup receiver This option only applies to PSTN Backup communications must be...

Page 127: ...llations 382 Communicator Option 3 1 Reserved 2 Walk Test Communications ON Zone alarms that occur during Walk Test are communicated if programmed to do so OFF Zone alarms during Walk Test are not communicated FMP key alarms are still communicated 4 Call Waiting Cancel ON The call waiting cancel string See 304 Call Waiting Cancel String on page 116 is used on the first attempt to dial each phone n...

Page 128: ... OFF Receiver 2 is independent and will communicate if a number and format are programmed 3 Receiver 3 Backup Option ON Receiver 3 backs up Receiver 2 Receiver 3 is only used if an FTC event is detected on Receiver 2 Receiver 3 uses the same format programmed for Receiver 2 OFF Receiver 3 is independent and will communicate if a number and format are programmed 4 Receiver 4 Backup Option ON Receiv...

Page 129: ...DLS window Note This feature controls the DLS window for PSTN connections only 2 User Enables Disables DLS ON The 6 Master Code 05 command enables a 6 hour window where on power up downloading calls are answered if a successful double call routine is detected OFF The user cannot enable a downloading window 3 DLS CallBack ON When a downloading call is answered both the computer and the alarm system...

Page 130: ...nnection When set to 000 default this feature is disabled Valid entries are 000 020 Note If Double Call option and Number of Rings to Answer are enabled either one will work depending on how the installer calls the alarm system 407 SA Access Code This 6 digit hexadecimal code allows the alarm system to confirm the identity of the downloading computer If the code does not match the computer the ala...

Page 131: ...t can be controlled by a third party integ ration Schedule Programming The sections described below are used for programming scheduled operating times for PGM command outputs 1 4 601 604 Programming Schedule 1 4 These sections are used to define schedules for PGM command outputs 1 4 operation When a PGM is configured for timed output operation it activates at the programmed start time and will tur...

Page 132: ...nstalled in order to enroll wireless devices Note Refer to the HSM2HOST installation manual for information Communicator Programming 850 Cellular Signal Strength This section is used to view both the cellular signal strength and the radio technology in use Table 5 4 Cellular Technology Display Technology GP GPRS ED EDGE HS HSPA H HSPA CD CDMA EV EVDO LT LTE 5 bars indicate maximum signal strength ...

Page 133: ... the programmed value is less than 10 seconds super vision is disabled 005 System Toggle Options 1 Ethernet Receiver 1 Supervised Default OFF ON Ethernet receiver 1 will be supervised and heartbeats will be sent to Ethernet receiver 1 based on the super vision interval programmed in section 004 OFF Ethernet receiver 1 will not be supervised When disabled heartbeat 1 is sent to the Ethernet receive...

Page 134: ...1 is disabled 2 Ethernet receiver 2 is enabled Default ON ON Ethernet receiver 2 is enabled OFF Ethernet receiver 2 is disabled 3 Reserved 4 Cellular receiver 3 is enabled Default ON ON Cellular receiver 3 is enabled OFF Cellular receiver 3 is disabled 5 Cellular receiver 4 is enabled Default ON ON Cellular receiver 4 is enabled OFF Cellular receiver 4 is disabled 6 Reserved 7 DLS Over Cellular De...

Page 135: ... protocol TCP port forward for this port to the com municator module IP address Valid range 00000 65535 013 DLS Outgoing Port Default 03066 The DLS outgoing port is used for outgoing sessions to DLS IV after an SMS request has been sent to the communicator Use this section to set the value of the local outgoing port The value must be changed if the communicator is located behind a firewall and mus...

Page 136: ...enezuela Standard Time 21 4 AST Atlantic Standard Time 23 3 5 NST Newfoundland Standard Time 25 3 ART Argentina Time 29 2 BEST Brazil Eastern Standard Time 2D 1 CVT Cape Verde Time 31 0 GMT Greenwich Mean Time UTC 35 1 CET Central European Time 39 2 SAST South Africa Standard Time 3D 3 AST Arabic Standard Time 3F 3 5 IRST Iran Standard Time 41 4 GST Gulf Standard Time 43 4 5 AFT Afghanistan Time 4...

Page 137: ... section 005 toggle option 7 Alternate Test Transmission with Backup Receivers Set Ethernet section 026 to FF 027 to 00 Set cellular section 028 to FF 029 to 00 Interval 1 l If the test transmission fails to the primary receiver it will back up to the secondary receiver l If the test transmission fails to the secondary receiver an FTC trouble will be generated Interval 2 l If the test transmission...

Page 138: ...t receiver 1 and cellular receiver 1 are programmed as the same receiver IP and port number are identical Ethernet receiver 1 account code will be used 102 Ethernet Receiver 1 DNIS Default 000000 The Dialed Number Information Service DNIS is used in addition to the account code to identify the communicator module at the central station Valid range 000000 099999 Value is entered as a leading 0 foll...

Page 139: ...receiver 2 IP address with 000 000 000 000 will disable Ethernet Enter the Ethernet receiver 2 IP address This address will be provided by the central station system administrator Format is 4 fields each field is a 3 digit decimal Valid range 000 255 Note When a valid IP address has been programmed Ethernet receiver 2 is enabled and will communicate events over the Ethernet channel Ethernet receiv...

Page 140: ...panel will use the control panel account number Valid range 0000000001 FFFFFFFFFE 202 Cellular Receiver 3 DNIS Default 000000 The DNIS is used in addition to the account code to identify the communicator module at the central station Valid range 000000 0FFFFF Values are entered as a leading 0 followed by the 6 digit DNIS Note Each Ethernet cellular receiver must be programmed with a unique DNIS 20...

Page 141: ...s section defines the port of cellular receiver 4 Change the value of this port when the installation is located behind a fire wall and must be assigned a particular port number as determined by the central station system administrator Valid range 00000 65535 Note Do not program cellular receiver 1 and cellular receiver 2 to communicate to the same receiver 215 Cellular Receiver 4 APN Default The ...

Page 142: ...lay in minutes for reporting a cellular trouble delay Valid entries are 000 255 When this section is programmed as 00 Cellular Ethernet and Supervision troubles are not communicated 227 Voice Call Timeout Default 000 Valid entries are 000 255 228 Voice Call Back Time Default 010 Valid entries are 000 255 229 Voice Call Back Number Default 32 digit phone number Valide entries 0000000000000001 to FF...

Page 143: ... the integration server port Refer to third party device manual for more information 431 Session 1 Integration Server DNS Enter the domain name up to 32 ASCII characters as provided by a third party device Refer to third party device manual for more information 432 Session 1 Integration Outgoing Port Default 03070 Valid range 00000 65535 This section is used to program the outgoing port for integr...

Page 144: ...atch 04 General variant mismatch 05 Firmware header wrong length Panel is Busy 20 System update pending panel is armed Disarm the panel to continue with system firmware update process 21 System update pending AC trouble Any AC trouble device module Resolve the AC trouble to continue with sys tem firmware update process 22 System update pending low battery Any low battery trouble device module Reso...

Page 145: ...e panel and also of the communicator itself This section does not provide specific details such as if the image is still stored or erased due to the cancellation code 984 Communicator Status The communicator status sections provide the installer with the status of the communicator s functionality operational read iness and failures The communicator status is displayed as a 6 digit hexadecimal code...

Page 146: ...s displayed as an 8 digit toggle option with each digit indicating a task in the initialization process 1 Radio power up 2 Received the SMS from C24 Communications 3 Radio reset 4 Radio attached to network 5 Receiver 1 initialized 6 Receiver 2 initialized 7 Receiver 3 initialized 8 Receiver 4 initialized For example the radio initialization status code 12 45 indicates that radio has been powered u...

Page 147: ...dynamic IP only The cellular IP address is always provided by the cellular network i e not pro grammable 995 SIM Number This section will display the Subscriber Identity Module SIM number of the SIM card installed in the communicator Format is Major Industry Identifier 2 digits Mobile Country Code 2 or 3 digits Mobile Network Code 2 3 digits Unique Number 10 12 digits and Checksum 1 digit Valid SI...

Page 148: ...ing 005 001 option 1 l Partition 1 Exit Delay The 3 digit exit delay duration for partition 1 in seconds used in programming section 005 001 option 3 l Installer Code The 4 6 or 8 digit installer access code used in programming section 006 001 For more information on template programming see Template programming tables on page 258 Systems Information 900 System Information 000 Control Panel Versio...

Page 149: ...ll new modules The auto enroll screen will show the following l KP Number of keypad type modules l IO Number of zone and output type modules l M Number of other type modules Devices are assigned to the next available slot The slot assignment can be modified using subsections 002 and 003 001 Enroll Modules To enroll modules individually 1 Enter programming section 902 001 2 When prompted key in the...

Page 150: ... 111 3A Power Supply Module 113 Corbus Repeater Module To confirm a module 1 Enter section 903 000 to view all enrolled modules or scroll to the module type you want to confirm 101 113 2 Press to select the module type then scroll to the specific module you want to confirm Press to enter Confirmation mode The module s serial number and slot number are displayed on the keypad and the status LEDs on...

Page 151: ...ess keys 911 Diagnostics This Diagnostics feature provides a live measurement of voltage current and battery condition for the alarm panel and devices through the system keypad This information can be used in place of a multimeter to troubleshoot panel and module troubles To view specific measurements scroll to the corresponding section 000 Panel 001 DC input voltage current 002 Battery voltage ba...

Page 152: ...munications occur for events from a zone in soak test with the exception of low battery and low battery restore events and faults generated by low sensitivity in a smoke detector A message indicating that the zone is in soak test is displayed when scrolling left or right in the base disarmed keypad menu Note Soak test is not applied to temperature detector events if it is enabled 982 Battery Setti...

Page 153: ...ds to factory default settings 901 916 Default Keypads 1 16 This section resets individual keypads to factory defaults After entering this section select the keypad to default key in the installer code then 991 or press 999 Default All Keypads This section resets all system keypads to factory defaults After entering this section key in the installer code then or 991 996 Default Wireless Receiver T...

Page 154: ... Norwegian 13 Danish 14 Hebrew 15 Greek 16 Turkish 18 Croatian 19 Hungarian 20 Romanian 21 Russian 22 Bulgarian 23 Latvian 24 Lithuanian 25 Ukrainian 26 Slovakian 27 Serbian 28 Estonian 29 Slovenian 000 001 Zone Labels 2 x 14 Characters Description on page 75 001 002 003 004 005 006 007 008 009 010 011 012 013 014 015 016 017 018 019 020 021 022 023 024 025 026 027 028 029 030 031 032 033 034 035 ...

Page 155: ...113 114 115 116 117 118 119 120 121 122 123 124 125 126 127 128 129 130 131 132 133 134 135 136 137 138 139 140 141 142 143 144 145 146 147 148 149 150 151 152 153 154 155 156 157 158 159 160 161 162 163 164 165 166 167 168 169 170 171 172 173 174 175 176 177 178 179 180 181 182 183 184 185 186 187 188 189 190 191 192 193 194 195 196 197 198 199 200 201 202 203 204 155 ...

Page 156: ...Partition 2 Label 1 x 14 Characters 103 Partition 3 Label 1 x 14 Characters 104 Partition 4 Label 1 x 14 Characters 105 Partition 5 Label 1 x 14 Characters 106 Partition 6 Label 1 x 14 Characters 107 Partition 7 Label 1 x 14 Characters 108 Partition 8 Label 1 x 14 Characters 201 Partition 1 Command Output Labels 001 Partition 1 Command Output 1 2 x 14 Characters 002 Partition 1 Command Output 2 De...

Page 157: ...and Output 3 004 Partition 6 Command Output 4 207 Partition 7 Command Output Labels 001 Partition 7 Command Output 1 2 x 14 Characters 002 Partition 7 Command Output 2 003 Partition 7 Command Output 3 004 Partition 7 Command Output 4 208 Partition 8 Command Output Labels 001 Partition 8 Command Output 1 2 x 14 Characters 002 Partition 8 Command Output 2 003 Partition 8 Command Output 3 004 Partiti...

Page 158: ...Expander 10 Label 003 Output Expander 3 Label 011 Output Expander 11 Label 004 Output Expander 4 Label 012 Output Expander 12 Label 005 Output Expander 5 Label 013 Output Expander 13 Label 006 Output Expander 6 Label 014 Output Expander 14 Label 007 Output Expander 7 Label 015 Output Expander 15 Label 008 Output Expander 8 Label 016 Output Expander 16 Label 804 HSM3408 8 I O Expansion Label 1 X 14...

Page 159: ...bel 004 3A Power Supply 4 Label 812 HSM3204CX Corbus Repeater Label 001 Corbus Repeater 1 Label 1 X 14 Characters 002 Corbus Repeater 2 Label 003 Corbus Repeater 3 Label 004 Corbus Repeater 4 Label 005 Corbus Repeater 5 Label 006 Corbus Repeater 6 Label 007 Corbus Repeater 7 Label 008 Corbus Repeater 8 Label 815 Alt Comm Label 1 X 14 ASCII Description on page 78 000 820 Siren Labels 001 Siren 1 La...

Page 160: ... Tamper 052 24 Hour Non Alarm 056 24 Hour High Temperature 057 24 Hour Low Temperature 060 24 Hour Non Latching Tamper 061 24 Hour Anti Masking 066 Momentary Keyswitch Arm 067 Maintained Keyswitch Arm 068 Momentary Keyswitch Disarm 069 Maintained Keyswitch Disarm 071 Door Bell 072 Push to Set 002 001 248 Zone Attributes Available Zone Attributes See next page for defaults Description on page 82 1 ...

Page 161: ...e ü ü ü ü ü ü 016 Final Door Set ü ü ü ü CP 01 ü CP 01 ü ü 017 24 Hour Burglary ü ü ü CP 01 ü CP 01 ü ü 018 24 Hour Bell Buzzer ü ü ü CP 01 ü CP 01 ü ü 023 24 Hour Supervisory ü ü CP 01 ü 024 24 Hour Supervisory Buzzer ü ü CP 01 ü CP 01 ü 025 Auto Verify Fire ü 027 Fire Supervisory 040 24 Hour Gas ü CP 01 ü CP 01 ü 041 24 Hour CO ü 042 24 Hour Holdup ü ü CP 01 ü CP 01 ü ü 043 24 Hour Panic ü ü CP ...

Page 162: ...lid range 0 5 kΩ to 15 kΩ 005 150 Tamper Default 5 6 kΩ Valid range 0 5 kΩ to 15 kΩ 005 150 003 Triple EOL Alarm Default 5 6 kΩ Valid range 0 5 kΩ to 7 5 kΩ 005 075 Tamper Default 5 6 kΩ Valid range 0 5 kΩ to 7 5 kΩ 005 075 6 4 System Times 005 System Times 000 System Area Bell Cutoff Default 004 minutes Description on page 84 3 Digit Decimal Bell Delay Time Default 000 minutes Burglary Verificati...

Page 163: ...ay 1 See partition 1 for defaults Entry Delay 2 Exit Delay Settle Delay 007 Partition 7 Timer Entry Delay 1 See partition 1 for defaults Entry Delay 2 Exit Delay Settle Delay 008 Partition 8 Timer Entry Delay 1 See partition 1 for defaults Entry Delay 2 Exit Delay Settle Delay 900 Bell Delay Partition Mask Default All partitions on 1 2 3 4 5 6 7 8 Y Y Y Y Y Y Y 901 Daylight Savings Begin Month Def...

Page 164: ...Partition Assignment Default Partition 1 on All others off Description on page 93 1 2 3 4 5 6 7 8 Y N N N N N N N 008 000 324 PGM Timer Programming 000 PGM Timers Minutes or Seconds o Minutes o Seconds 001 324 PGM 1 to 324 3 Digit Decimal Valid Range 001 255 Default 005 Description on page 87 PGM Zone Follower by Zone 000 248 Default 000 Prox Used 000 095 Default 000 Schedule 000 004 Default 000 A...

Page 165: ...1 042 PGM 42 043 PGM 43 044 PGM 44 HSM2208 2 045 PGM 45 046 PGM 46 047 PGM 47 048 PGM 48 049 PGM 49 050 PGM 50 051 PGM 51 052 PGM 52 HSM2208 3 053 PGM 53 054 PGM 54 055 PGM 55 056 PGM 56 057 PGM 57 058 PGM 58 059 PGM 59 060 PGM 60 HSM2208 4 061 PGM 61 062 PGM 62 063 PGM 63 064 PGM 64 065 PGM 65 066 PGM 66 067 PGM 67 068 PGM 68 HSM2208 5 069 PGM 69 070 PGM 70 071 PGM 71 072 PGM 72 165 ...

Page 166: ...GM 83 084 PGM 84 HSM2208 7 085 PGM 85 086 PGM 86 087 PGM 87 088 PGM 88 089 PGM 89 090 PGM 90 091 PGM 91 092 PGM 92 HSM2208 8 093 PGM 93 094 PGM 94 095 PGM 95 096 PGM 96 097 PGM 97 098 PGM 98 099 PGM 99 100 PGM 100 HSM2208 9 101 PGM 101 102 PGM 102 103 PGM 103 104 PGM 104 105 PGM 105 106 PGM 106 107 PGM 107 108 PGM 108 HSM2208 10 109 PGM 109 110 PGM 110 111 PGM 111 112 PGM 112 113 PGM 113 166 ...

Page 167: ...4 HSM2208 12 125 PGM 125 126 PGM 126 127 PGM 127 128 PGM 128 129 PGM 129 130 PGM 130 131 PGM 131 132 PGM 132 HSM2208 13 133 PGM 133 134 PGM 134 135 PGM 135 136 PGM 136 137 PGM 137 138 PGM 138 139 PGM 139 140 PGM 140 HSM2208 14 141 PGM 141 142 PGM 142 143 PGM 143 144 PGM 144 145 PGM 145 146 PGM 146 147 PGM 147 148 PGM 148 HSM2208 15 149 PGM 149 150 PGM 150 151 PGM 151 152 PGM 152 153 PGM 153 154 PG...

Page 168: ...293 PGM 293 HSM3204CX 17 294 PGM 294 295 PGM 295 296 PGM 296 297 PGM 297 298 PGM 298 299 PGM 299 300 PGM 300 301 PGM 301 302 PGM 302 303 PGM 303 304 PGM 304 305 PGM 305 306 PGM 306 307 PGM 307 308 PGM 308 309 PGM 309 310 PGM 310 311 PGM 311 312 PGM 312 313 PGM 313 314 PGM 314 315 PGM 315 316 PGM 316 317 PGM 317 318 PGM 318 319 PGM 319 320 PGM 320 321 PGM 321 322 PGM 322 323 PGM 323 324 PGM 324 168...

Page 169: ...Hr Audible Input 184 Open After Alarm 212 Follower Zones 89 96 114 Ready To Arm 146 TLM and Alarm 200 Zone Follower 213 Follower Zones 97 104 115 System Armed Status 147 Kissoff 201 Follower Zones 1 8 214 Follower Zones 105 112 116 Away Armed Status 148 Ground Start 202 Follower Zones 9 16 215 Follower Zones 113 120 117 Stay Armed Status 149 Alt Communicator 203 Follower Zones 17 24 216 Follower Z...

Page 170: ...GM 37 038 PGM 38 039 PGM 39 040 PGM 40 041 PGM 41 042 PGM 42 043 PGM 43 044 PGM 44 HSM2208 2 045 PGM 45 046 PGM 46 047 PGM 47 048 PGM 48 049 PGM 49 050 PGM 50 051 PGM 51 052 PGM 52 HSM2208 3 053 PGM 53 054 PGM 54 055 PGM 55 056 PGM 56 057 PGM 57 058 PGM 58 059 PGM 59 060 PGM 60 HSM2208 4 061 PGM 61 062 PGM 62 063 PGM 63 064 PGM 64 065 PGM 65 066 PGM 66 067 PGM 67 068 PGM 68 170 ...

Page 171: ...PGM 78 079 PGM 79 080 PGM 80 081 PGM 81 082 PGM 82 083 PGM 83 084 PGM 84 HSM2208 7 085 PGM 85 086 PGM 86 087 PGM 87 088 PGM 88 089 PGM 89 090 PGM 90 091 PGM 91 092 PGM 92 HSM2208 8 093 PGM 93 094 PGM 94 095 PGM 95 096 PGM 96 097 PGM 97 098 PGM 98 099 PGM 99 100 PGM 100 HSM2208 9 101 PGM 101 102 PGM 102 103 PGM 103 104 PGM 104 105 PGM 105 106 PGM 106 107 PGM 107 108 PGM 108 171 ...

Page 172: ... 119 PGM 119 120 PGM 120 121 PGM 121 122 PGM 122 123 PGM 123 124 PGM 124 HSM2208 12 125 PGM 125 126 PGM 126 127 PGM 127 128 PGM 128 129 PGM 129 130 PGM 130 131 PGM 131 132 PGM 132 HSM2208 13 133 PGM 133 134 PGM 134 135 PGM 135 136 PGM 136 137 PGM 137 138 PGM 138 139 PGM 139 140 PGM 140 HSM2208 14 141 PGM 141 142 PGM 142 143 PGM 143 144 PGM 144 145 PGM 145 146 PGM 146 147 PGM 147 148 PGM 148 172 ...

Page 173: ... 158 159 PGM 159 160 PGM 160 161 PGM 161 162 PGM 162 163 PGM 163 164 PGM 164 293 PGM 293 HSM3204CX 17 294 PGM 294 295 PGM 295 296 PGM 296 297 PGM 297 298 PGM 298 299 PGM 299 300 PGM 300 301 PGM 301 302 PGM 302 303 PGM 303 304 PGM 304 305 PGM 305 306 PGM 306 307 PGM 307 308 PGM 308 309 PGM 309 310 PGM 310 311 PGM 311 312 PGM 312 313 PGM 313 314 PGM 314 315 PGM 315 316 PGM 316 317 PGM 317 173 ...

Page 174: ...2 o 03 Code Required 107 External Siren R 01 True Output 109 Courtesy Pulse R 01 True Output 111 Keypad Buzzer Follow R 01 True Output o 02 Timed Output R 09 Entry Delay R 10 Exit Delay R 11 Door Chime R 12 Keypad Buzzer Zone R 13 Audible Exit Zone R 14 Auto Arm Pre Alert 114 Ready To Arm R 01 True Output 115 Armed Status R 01 True Output 116 Armed Away Mode R 01 True Output 117 Armed Stay Mode R ...

Page 175: ...148 Ground Start R 01 True Output 149 Alternate Communicator R 01 True Output R 02 Timed Output o 04 Fire Alarm o 05 Panic Alarm o 06 Burglary Alarm o 07 Open Close o 08 Zone Auto Bypass o 09 Medical Alarm o 10 Burglary Verified o 11 Open After Alarm o 12 Emergency Alarm o 13 Duress Alarm o 14 Holdup Verified 155 System Trouble R 01 True Output o 02 Timed Output R 04 Service Required R 05 Loss of ...

Page 176: ... R 15 CO Alarm 157 System Tamper R 01 True Output o 02 Timed Output R 09 Module Tamper R 10 Zone Tampers 161 DC Trouble R 01 True Output o 02 Timed Output R 09 Battery Low R 10 Battery Absent 165 Prox Used R 01 True Output 166 Prox Used Part R 01 True Output o 02 Timed Output 175 Bell Prog Access R 01 True Output 176 Remote Operation R 01 True Output o 02 Timed Output 184 Open After Alarm R 01 Tru...

Page 177: ...r Zones 89 96 213 Zone Follower Zones 97 104 214 Zone Follower Zones 105 112 215 Zone Follower Zones 113 120 216 Zone Follower Zones 121 128 217 Zone Follower Zones 129 136 218 Zone Follower Zones 137 144 219 Zone Follower Zones 145 152 220 Zone Follower Zones 153 160 221 Zone Follower Zones 161 168 222 Zone Follower Zones 169 176 223 Zone Follower Zones 177 184 224 Zone Follower Zones 185 192 225...

Page 178: ... PGM 6 007 PGM 7 008 PGM 8 HSM2204 2 009 PGM 9 010 PGM 10 011 PGM 11 012 PGM 12 HSM2204 3 013 PGM 13 014 PGM 14 015 PGM 15 016 PGM 16 HSM2204 4 017 PGM 17 018 PGM 18 019 PGM 19 020 PGM 20 HSM2208 1 037 PGM 37 038 PGM 38 039 PGM 39 040 PGM 40 041 PGM 41 042 PGM 42 043 PGM 43 044 PGM 44 HSM2208 2 045 PGM 45 046 PGM 46 047 PGM 47 048 PGM 48 049 PGM 49 050 PGM 50 051 PGM 51 052 PGM 52 HSM2208 3 053 PG...

Page 179: ...GM 58 059 PGM 59 060 PGM 60 HSM2208 4 061 PGM 61 062 PGM 62 063 PGM 63 064 PGM 64 065 PGM 65 066 PGM 66 067 PGM 67 068 PGM 68 HSM2208 5 069 PGM 69 070 PGM 70 071 PGM 71 072 PGM 72 073 PGM 73 074 PGM 74 075 PGM 75 076 PGM 76 HSM2208 6 077 PGM 77 078 PGM 78 079 PGM 79 080 PGM 80 081 PGM 81 082 PGM 82 083 PGM 83 084 PGM 84 HSM2208 7 085 PGM 85 086 PGM 86 087 PGM 87 088 PGM 88 089 PGM 89 090 PGM 90 09...

Page 180: ...096 PGM 96 097 PGM 97 098 PGM 98 099 PGM 99 100 PGM 100 HSM2208 9 101 PGM 101 102 PGM 102 103 PGM 103 104 PGM 104 105 PGM 105 106 PGM 106 107 PGM 107 108 PGM 108 HSM2208 10 109 PGM 109 110 PGM 110 111 PGM 111 112 PGM 112 113 PGM 113 114 PGM 114 115 PGM 115 116 PGM 116 HSM2208 11 117 PGM 117 118 PGM 118 119 PGM 119 120 PGM 120 121 PGM 121 122 PGM 122 123 PGM 123 124 PGM 124 HSM2208 12 125 PGM 125 1...

Page 181: ...33 PGM 133 134 PGM 134 135 PGM 135 136 PGM 136 137 PGM 137 138 PGM 138 139 PGM 139 140 PGM 140 HSM2208 14 141 PGM 141 142 PGM 142 143 PGM 143 144 PGM 144 145 PGM 145 146 PGM 146 147 PGM 147 148 PGM 148 HSM2208 15 149 PGM 149 150 PGM 150 151 PGM 151 152 PGM 152 153 PGM 153 154 PGM 154 155 PGM 155 156 PGM 156 HSM2208 16 157 PGM 157 158 PGM 158 159 PGM 159 160 PGM 160 161 PGM 161 162 PGM 162 163 PGM ...

Page 182: ...0 301 PGM 301 302 PGM 302 303 PGM 303 304 PGM 304 305 PGM 305 306 PGM 306 307 PGM 307 308 PGM 308 309 PGM 309 310 PGM 310 311 PGM 311 312 PGM 312 313 PGM 313 314 PGM 314 315 PGM 315 316 PGM 316 317 PGM 317 318 PGM 318 319 PGM 319 320 PGM 320 321 PGM 321 322 PGM 322 323 PGM 323 324 PGM 324 011 PGM Config Options Description on page 100 PGM Zone Follower by Zone 000 248 Default 000 Prox Used 000 095...

Page 183: ... 007 PGM 7 008 PGM 8 HSM2204 2 009 PGM 9 010 PGM 10 011 PGM 11 012 PGM 12 HSM2204 3 013 PGM 13 014 PGM 14 015 PGM 15 016 PGM 16 HSM2204 4 017 PGM 17 018 PGM 18 019 PGM 19 020 PGM 20 HSM2208 1 037 PGM 37 038 PGM 38 039 PGM 39 040 PGM 40 041 PGM 41 042 PGM 42 043 PGM 43 044 PGM 44 HSM2208 2 045 PGM 45 046 PGM 46 047 PGM 47 048 PGM 48 049 PGM 49 050 PGM 50 051 PGM 51 052 PGM 52 HSM2208 3 053 PGM 53 0...

Page 184: ...PGM 59 060 PGM 60 HSM2208 4 061 PGM 61 062 PGM 62 063 PGM 63 064 PGM 64 065 PGM 65 066 PGM 66 067 PGM 67 068 PGM 68 HSM2208 5 069 PGM 69 070 PGM 70 071 PGM 71 072 PGM 72 073 PGM 73 074 PGM 74 075 PGM 75 076 PGM 76 HSM2208 6 077 PGM 77 078 PGM 78 079 PGM 79 080 PGM 80 081 PGM 81 082 PGM 82 083 PGM 83 084 PGM 84 HSM2208 7 085 PGM 85 086 PGM 86 087 PGM 87 088 PGM 88 089 PGM 89 090 PGM 90 091 PGM 91 0...

Page 185: ...GM 97 098 PGM 98 099 PGM 99 100 PGM 100 HSM2208 9 101 PGM 101 102 PGM 102 103 PGM 103 104 PGM 104 105 PGM 105 106 PGM 106 107 PGM 107 108 PGM 108 HSM2208 10 109 PGM 109 110 PGM 110 111 PGM 111 112 PGM 112 113 PGM 113 114 PGM 114 115 PGM 115 116 PGM 116 HSM2208 11 117 PGM 117 118 PGM 118 119 PGM 119 120 PGM 120 121 PGM 121 122 PGM 122 123 PGM 123 124 PGM 124 HSM2208 12 125 PGM 125 126 PGM 126 127 P...

Page 186: ...M 135 136 PGM 136 137 PGM 137 138 PGM 138 139 PGM 139 140 PGM 140 HSM2208 14 141 PGM 141 142 PGM 142 143 PGM 143 144 PGM 144 145 PGM 145 146 PGM 146 147 PGM 147 148 PGM 148 HSM2208 15 149 PGM 149 150 PGM 150 151 PGM 151 152 PGM 152 153 PGM 153 154 PGM 154 155 PGM 155 156 PGM 156 HSM2208 16 157 PGM 157 158 PGM 158 159 PGM 159 160 PGM 160 161 PGM 161 162 PGM 162 163 PGM 163 164 PGM 164 293 PGM 293 H...

Page 187: ...2 303 PGM 303 304 PGM 304 305 PGM 305 306 PGM 306 307 PGM 307 308 PGM 308 309 PGM 309 310 PGM 310 311 PGM 311 312 PGM 312 313 PGM 313 314 PGM 314 315 PGM 315 316 PGM 316 317 PGM 317 318 PGM 318 319 PGM 319 320 PGM 320 321 PGM 321 322 PGM 322 323 PGM 323 324 PGM 324 6 7 System Lockout 012 System Lockout 3 Digit Decimal Description on page 101 Keypad Lockout Range 000 255 Default 000 Note For EN ins...

Page 188: ...in 6 R 6 Audible Exit Fault R 7 Event Buffer Follows Swinger o 8 Temporal Three Fire Signaling 014 System Options 2 Description on page 102 o 1 Bell Squawk o 2 Bell Squawk on Auto Arm o 3 Bell Squawk on Exit o 4 Bell Squawk on Entry o 5 Bell Squawk on Trouble o 6 Reserved o 7 Exit Delay Termination o 8 Fire Bell Continues 015 System Options 3 Description on page 103 R1 F Key Enabled o 2 P Key Annu...

Page 189: ...n Closing EN R 2 Chime on Closing o3 Audible RF Jam Trouble Beeps o 4 Multi Hit o 5 Late to Close o 6 Daylight Savings Time o7 Silence Chime During Quick Exit Delay o 8 Bell Squawk on Away Arm Disarm 018 System Options 6 Description on page 106 o 1 Test Transmission Exception o 2 Real Time Bypass Reporting o 3 Report Bypass for Stay Away Zones o 4 Auto Bypass Report o 5 Keypad Buzzer Alarm o 6 Res...

Page 190: ...emote Reset o 5 Engineer s Reset o 6 Keyswitch Disarming During Entry Delay o 7 Installer Access and DLS EN R 7 Installer Access and DLS o 8 Troubles Inhibits Arming EN R 8 Troubles Inhibits Arming 021 System Options 9 Description on page 109 EN o 1 Trouble Display EN o 2 Keypad Blanking While Armed o 3 Reserved o 4 Ready Display o 5 PGM Keypad Blanking EN R 5 PGM Keypad Blanking o 6 Armed Display...

Page 191: ...cess Code Required for 1 o 5 Access Code Required for 2 Note For UL installations this setting must be enabled EN R 5 Access Code Required for 2 o 6 Access Code Required for 3 EN R 6 Access Code Required for 3 o 7 Access Code Required for 4 EN R 7 Access Code Required for 4 o 8 6 Accessibility Option 024 System Options 12 Description on page 111 o 1 Reserved o 2 Reserved o 3 AC DC Inhibits Arming ...

Page 192: ...002 02 Holdup Counter Default 002 03 BurglaryVerification Selection 001 Police Code Default 002 Cross Zoning 003 Sequential Detection 6 9 Auto Arm_Disarm 151 Partition 1 Auto Arm Disarm Description on page 113 001 Partition 1 Auto Arming Times 24 Hour 4 digit HH MM Sunday Thursday Default 9999 Monday Friday Tuesday Saturday Wednesday 002 Partition 1 Auto Disarm Times 24 Hour 4 digit HH MM Sunday T...

Page 193: ... Arming Pre Alert Default 004 005 Partition 2 Auto Arming Postpone Timer Default 000 006 Partition 2 No Activity Arming Timer Default 000 007 Partition 2 No Activity Arming Pre Alert Timer Default 001 153 Partition 3 Auto Arm Disarm 001 Partition 3 Auto Arming Times 24 Hour 4 digit HH MM Sunday Thursday Default 9999 Monday Friday Tuesday Saturday Wednesday 002 Partition 3 Auto Disarm Times 24 Hour...

Page 194: ... 007 Partition 4 No Activity Arming Pre Alert Timer Default 001 155 Partition 5 Auto Arm Disarm 001 Partition 5 Auto Arming Times 24 Hour 4 digit HH MM Sunday Thursday Default 9999 Monday Friday Tuesday Saturday Wednesday 002 Partition 5 Auto Disarm Times 24 Hour 4 digit HH MM Sunday Thursday Default 9999 Monday Friday Tuesday Saturday Wednesday 003 Partition 2 Auto Disarming Holiday Schedule Holi...

Page 195: ...Partition 7 Auto Arming Times 24 Hour 4 digit HH MM Sunday Thursday Default 9999 Monday Friday Tuesday Saturday Wednesday 002 Partition 7 Auto Disarm Times 24 Hour 4 digit HH MM Sunday Thursday Default 9999 Monday Friday Tuesday Saturday Wednesday 003 Partition 7 Auto Disarming Holiday Schedule Holiday 1 o On R Off 3 digit decimal Holiday 2 o On R Off Holiday 3 o On R Off Holiday 4 o On R Off 004 ...

Page 196: ...Partition 7 o Partition 8 6 10 Partition and Zone Assignment 201 208 Partition Zone Assignment Description on page 115 201 Partition 1 Zone Assignment 202 Partition 2 Zone Assignment Bit 1 2 3 4 5 6 7 8 Bit 1 2 3 4 5 6 7 8 001 01 08 R R R R R R R R 001 01 08 o o o o o o o o 002 09 16 R R R R R R R R 002 09 16 o o o o o o o o 003 17 24 o o o o o o o o 003 17 24 o o o o o o o o 004 25 32 o o o o o o...

Page 197: ...o o 031 241 248 o o o o o o o o 203 Partition 3 Zone Assignment 204 Partition 4 Zone Assignment Bit 1 2 3 4 5 6 7 8 Bit 1 2 3 4 5 6 7 8 001 01 08 o o o o o o o o 001 01 08 o o o o o o o o 002 09 16 o o o o o o o o 002 09 16 o o o o o o o o 003 17 24 o o o o o o o o 003 17 24 o o o o o o o o 004 25 32 o o o o o o o o 004 25 32 o o o o o o o o 005 33 40 o o o o o o o o 005 33 40 o o o o o o o o 006 ...

Page 198: ... 57 64 o o o o o o o o 008 57 64 o o o o o o o o 009 65 72 o o o o o o o o 009 65 72 o o o o o o o o 010 73 80 o o o o o o o o 010 73 80 o o o o o o o o 011 81 88 o o o o o o o o 011 81 88 o o o o o o o o 012 89 96 o o o o o o o o 012 89 96 o o o o o o o o 013 97 104 o o o o o o o o 013 97 104 o o o o o o o o 014 105 112 o o o o o o o o 014 105 112 o o o o o o o o 015 113 120 o o o o o o o o 015 1...

Page 199: ... o o o o o 014 105 112 o o o o o o o o 014 105 112 o o o o o o o o 015 113 120 o o o o o o o o 015 113 120 o o o o o o o o 016 121 128 o o o o o o o o 016 121 128 o o o o o o o o 022 169 176 o o o o o o o o 022 169 176 o o o o o o o o 023 177 184 o o o o o o o o 023 177 184 o o o o o o o o 024 185 192 o o o o o o o o 024 185 192 o o o o o o o o 025 193 200 o o o o o o o o 025 193 200 o o o o o o o...

Page 200: ...one Number Programming 004 Receiver 4 Phone Number Programming 304 Call Waiting Cancel String Description on page 116 Call Waiting Cancel String 6 digit Hex Default DB70EF CP 01 Default FFFFFF 307 Zone Reporting Description on page 116 001 248 zones 1 248 R 1 Alarm R 2 Alarm Restore R 3 Tamper R 4 Tamper Restore R 5 Fault R 6 Fault Restore 001 RRRRRRoo 1 2 3 4 5 6 7 8 002 RRRRRRoo 1 2 3 4 5 6 7 8 ...

Page 201: ...072 RRRRRRoo 1 2 3 4 5 6 7 8 073 RRRRRRoo 1 2 3 4 5 6 7 8 074 RRRRRRoo 1 2 3 4 5 6 7 8 075 RRRRRRoo 1 2 3 4 5 6 7 8 076 RRRRRRoo 1 2 3 4 5 6 7 8 077 RRRRRRoo 1 2 3 4 5 6 7 8 078 RRRRRRoo 1 2 3 4 5 6 7 8 079 RRRRRRoo 1 2 3 4 5 6 7 8 080 RRRRRRoo 1 2 3 4 5 6 7 8 081 RRRRRRoo 1 2 3 4 5 6 7 8 082 RRRRRRoo 1 2 3 4 5 6 7 8 083 RRRRRRoo 1 2 3 4 5 6 7 8 084 RRRRRRoo 1 2 3 4 5 6 7 8 085 RRRRRRoo 1 2 3 4 5 ...

Page 202: ...182 RRRRRRoo 1 2 3 4 5 6 7 8 183 RRRRRRoo 1 2 3 4 5 6 7 8 184 RRRRRRoo 1 2 3 4 5 6 7 8 185 RRRRRRoo 1 2 3 4 5 6 7 8 186 RRRRRRoo 1 2 3 4 5 6 7 8 187 RRRRRRoo 1 2 3 4 5 6 7 8 188 RRRRRRoo 1 2 3 4 5 6 7 8 189 RRRRRRoo 1 2 3 4 5 6 7 8 190 RRRRRRoo 1 2 3 4 5 6 7 8 191 RRRRRRoo 1 2 3 4 5 6 7 8 192 RRRRRRoo 1 2 3 4 5 6 7 8 193 RRRRRRoo 1 2 3 4 5 6 7 8 194 RRRRRRoo 1 2 3 4 5 6 7 8 195 RRRRRRoo 1 2 3 4 5 ...

Page 203: ...urglary Not Verified Alarm R 8 Alarm Cancel 002 Miscellaneous Alarm 2 R 1 Holdup Verified Alarm 011 Priority Alarms 1 R 1 Keypad Fire Alarm F Key R 2 Keypad Fire Restore R 3 Keypad Medical Alarm M Key R 4 Keypad Medical Restore R 5 Keypad Panic Alarm P Key Alarm R 6 Keypad Panic Restore R 7 Auxiliary Input Alarm R 8 Auxiliary Input Alarm Restore 021 Fire Alarms 1 R 3 PGM 2 2 Wire Alarm R 4 PGM 2 2...

Page 204: ...wer Unit Failure R 8 Panel Power Unit Fail Restore 302 Panel Events 2 R 1 Bell Circuit Trouble R 2 Bell Circuit Trouble Restore R 3 Telephone Line Trouble R 4 Telephone Line Trouble Restore R 5 Auxiliary Trouble R 6 Auxiliary Trouble Restore R 7 Overcurrent Trouble R 8 Overcurrent Trouble Restore 305 Panel Events 5 R 3 PGM 2 2 Wire Trouble R 4 PGM 2 2 Wire Trouble Restore 311 Maintenance Events 1 ...

Page 205: ... Update Successful R 3 Firmware Update Fail 314 Maintenance Events 4 R 1 Gas Trouble R 2 Gas Trouble Restore R 3 Heat Trouble R 4 Heat Trouble Restore R 5 Freeze Trouble R 6 Freeze Trouble Restore R 7 Probe Disconnected Trouble R 8 Probe Disconnected Restore 321 Receiver Events R2 Receiver 1 FTC Restore R4 Receiver 2 FTC Restore R6 Receiver 3 FTC Restore R8 Receiver 4 FTC Restore 331 Module Events...

Page 206: ... R 2 Alt Comm Receiver 1 Restore R 3 Alt Comm Receiver 2 Trouble R 4 Alt Comm Receiver 2 Restore R 5 Alt Comm Receiver 3 Trouble R 6 Alt Comm Receiver 3 Restore R 7 Alt Comm Receiver 4 Trouble R8 Alt Comm Receiver 4 Restore 355 Alternate Communicator 5 R 1 Alt Comm Receiver 1 Supervision Failure R 2 Alt Comm Receiver 1 Supervision Restore R 3 Alt Comm Receiver 2 Supervision Failure R 4 Alt Comm Re...

Page 207: ... Account Code 311 Partition 1 Call Directions Description on page 123 001 Partition 1 Alarm Restore R Receiver 1 RReceiver 3 R Receiver 2 RReceiver 4 002 Partition 1 Tamper Restore R Receiver 1 R Receiver 3 R Receiver 2 R Receiver 4 003 Partition 1 Opening Closing oReceiver 1 o Receiver 3 o Receiver 2 o Receiver 4 312 Partition 2 Call Directions 001 Partition 2 Alarm Restore R Receiver 1 R Receive...

Page 208: ... R Receiver 1 RReceiver 3 R Receiver 2 R Receiver 4 002 Partition 6 Tamper Restore R Receiver 1 R Receiver 3 RReceiver 2 RReceiver 4 003 Partition 6 Opening Closing o Receiver 1 o Receiver 3 o Receiver 2 o Receiver 4 317 Partition 7 Call Directions 001 Partition 7 Alarm Restore R Receiver 1 RReceiver 3 RReceiver 2 RReceiver 4 002 Partition 7 Tamper Restore R Receiver 1 RReceiver 3 RReceiver 2 RRec...

Page 209: ...lt 000 minutes CP 01 Default 005 minutes 003 Periodic Test Transmission Cycle Default 030 hours days Note For UL installations the periodic test transmissions default is 07 days 004 Periodic Test Transmission Time of Day Default 9999 011 Maximum Dialing Attempts Default 005 012 Delay Between PSTN Attempts Default 003 seconds 013 Delay Between Force Attempts Default 020 seconds 014 Post Dial Wait f...

Page 210: ...Digit Account Code 3 oEthernet Enable 4 oCellular Enable 5 o Communicate FTC Events 384 Communicator Backup Options 2 R Backup Options Receiver 2 Description on page 128 3 o Backup Options Receiver 3 4 o Backup Options Receiver 4 385 Audio Module Talk Listen Mask Description on page 128 1 oTalk Listen on Receiver 1 2 oTalk Listen on Receiver 2 3 oTalk Listen on Receiver 3 4 oTalk Listen on Receive...

Page 211: ...5 Default 000 days 003 Periodic DLS Time 4 digit decimal HH MM 0000 2359 Default 0000 007 Delay Call Window Start 4 digit decimal 0000 2359 HH MM 1 0000 Delay Call Window Start Default 0000 2 0000 Delay Call Window End 6 14 Virtual Inputs 560 Virtual Inputs 3 digit decimal 001 Virtual Input 1 017 Virtual Input 17 002 Virtual Input 2 018 Virtual Input 18 Description on page 131 003 Virtual Input 3 ...

Page 212: ...me 203 Days Assignment 204 Holiday Assignment 4 digit decimal 01 o Sunday o Holiday 1 HH MM 02 o Monday o Holiday 2 to HH MM 03 o Tuesday o Holiday 3 Default 0000 04 o Wednesday o Holiday 4 05 o Thursday 06 o Friday 07 o Saturday Interval 3 301 Start Time 302 End Time 303 Days Assignment 304 Holiday Assignment 4 digit decimal 01 o Sunday o Holiday 1 HH MM 02 o Monday o Holiday 2 to HH MM 03 o Tues...

Page 213: ...liday 3 Default 0000 04 o Wednesday o Holiday 4 05 o Thursday 06 o Friday 07 o Saturday Interval 3 301 Start Time 302 End Time 303 Days Assignment 304 Holiday Assignment 4 digit decimal 01 o Sunday o Holiday 1 HH MM 02 o Monday o Holiday 2 to HH MM 03 o Tuesday o Holiday 3 Default 0000 04 o Wednesday o Holiday 4 05 o Thursday 06 o Friday 07 o Saturday Interval 4 401 Start Time 402 End Time 403 Day...

Page 214: ...304 Holiday Assignment 4 digit decimal 01 o Sunday o Holiday 1 HH MM 02 o Monday o Holiday 2 to HH MM 03 o Tuesday o Holiday 3 Default 0000 04 o Wednesday o Holiday 4 05 o Thursday 06 o Friday 07 o Saturday Interval 4 401 Start Time 402 End Time 403 Days Assignment 404 Holiday Assignment 4 digit decimal 01 o Sunday o Holiday 1 HH MM 02 o Monday o Holiday 2 to HH MM 03 o Tuesday o Holiday 3 Default...

Page 215: ...o Wednesday o Holiday 4 05 o Thursday 06 o Friday 07 o Saturday Interval 4 401 Start Time 402 End Time 403 Days Assignment 404 Holiday Assignment 4 digit decimal 01 o Sunday o Holiday 1 HH MM to HH MM 02 o Monday o Holiday 2 Default 0000 03 o Tuesday o Holiday 3 04 o Wednesday o Holiday 4 05 o Thursday 06 o Friday 07 o Saturday 711 Holiday Group 1 6 Digit Decimal 001 Holiday Group 1 Date 1 MMDDYY ...

Page 216: ...Date 5 006 Holiday Group 3 Date 6 007 Holiday Group 3 Date 7 008 Holiday Group 3 Date 8 009 099 Holiday Group 3 Date 9 99 714 Holiday Group 4 6 Digit Decimal 001 Holiday Group 4 Date 1 MMDDYY 002 Holiday Group 4 Date 2 Default 000000 003 Holiday Group 4 Date 3 004 Holiday Group 4 Date 4 005 Holiday Group 4 Date 5 Description on page 132 006 Holiday Group 4 Date 6 007 Holiday Group 4 Date 7 008 Hol...

Page 217: ... Station Assignment 023 Zone 23 Station Assignment 024 Zone 24 Station Assignment 025 Zone 25 Station Assignment 026 Zone 26 Station Assignment 027 Zone 27 Station Assignment 028 Zone 28 Station Assignment 029 Zone 29 Station Assignment 030 Zone 30 Station Assignment 031 Zone 31 Station Assignment 032 Zone 32 Station Assignment 033 Zone 33 Station Assignment 034 Zone 34 Station Assignment 035 Zone...

Page 218: ... 64 Station Assignment 065 Zone 65 Station Assignment 066 Zone 66 Station Assignment 067 Zone 67 Station Assignment 068 Zone 68 Station Assignment 069 Zone 69 Station Assignment 070 Zone 70 Station Assignment 071 Zone 71 Station Assignment 072 Zone 72 Station Assignment 073 Zone 73 Station Assignment 074 Zone 74 Station Assignment 075 Zone 75 Station Assignment 076 Zone 76 Station Assignment 077 Z...

Page 219: ...on Assignment 107 Zone 107 Station Assignment 108 Zone 108 Station Assignment 109 Zone 109 Station Assignment 110 Zone 110 Station Assignment 111 Zone 111 Station Assignment 112 Zone 112 Station Assignment 113 Zone 113 Station Assignment 114 Zone 114 Station Assignment 115 Zone 115 Station Assignment 116 Zone 116 Station Assignment 117 Zone 117 Station Assignment 118 Zone 118 Station Assignment 11...

Page 220: ... Station Assignment 149 Zone 149 Station Assignment 150 Zone 150 Station Assignment 151 Zone 151 Station Assignment 152 Zone 152 Station Assignment 153 Zone 153 Station Assignment 154 Zone 154 Station Assignment 155 Zone 155 Station Assignment 156 Zone 156 Station Assignment 157 Zone 157 Station Assignment 158 Zone 158 Station Assignment 159 Zone 159 Station Assignment 160 Zone 160 Station Assignm...

Page 221: ... Station Assignment 191 Zone 191 Station Assignment 192 Zone 192 Station Assignment 193 Zone 193 Station Assignment 194 Zone 194 Station Assignment 195 Zone 195 Station Assignment 196 Zone 196 Station Assignment 197 Zone 197 Station Assignment 198 Zone 198 Station Assignment 199 Zone 199 Station Assignment 200 Zone 200 Station Assignment 201 Zone 201 Station Assignment 202 Zone 202 Station Assignm...

Page 222: ... Station Assignment 229 Zone 229 Station Assignment 230 Zone 230 Station Assignment 231 Zone 231 Station Assignment 232 Zone 232 Station Assignment 233 Zone 233 Station Assignment 234 Zone 234 Station Assignment 235 Zone 235 Station Assignment 236 Zone 236 Station Assignment 237 Zone 237 Station Assignment 238 Zone 238 Station Assignment 239 Zone 239 Station Assignment 240 Zone 240 Station Assignm...

Page 223: ...R 2 Way Audio Initiated by CS 605 Record Options 1 R Audio Capture Enable 2 o Erase on FTC 3 o Future Use 4 o Future Use 5 o Future Use 6 o Future Use 7 o Future Use 8 o Future Use 606 Audio Station Record Control Option 1 1 o Audio Station 1 Record 2 o Audio Station 2 Record 3 o Audio Station 3 Record 4 o Audio Station 4 Record 5 o Future Use 6 o Future Use 7 o Future Use 8 o Future Use 610 Call ...

Page 224: ...reless Programming See the HSM2HOSTx installation manual and wireless device installation sheets for detailed information 000 WLS Device Enrollment Zones Selection Zone Zone Definition 2 digit decimal Partition Assignment 14 x 2 Zone Label This section is an overview of wireless device programming See the associated device installation sheets and the HSM2HOST RFK keypad installation instructions f...

Page 225: ...cator Programming Local IP configuration 001 Ethernet IP Address Default 000 000 000 000 002 Ethernet IP Subnet Mask Default 255 255 255 000 003 Ethernet Gateway IP Address Default 000 000 000 000 004 Receiver Supervision Interval Default 00087 135 Valid range 00000 65535 005 System Toggle Options 1 o 1 Receiver 1 Supervised o 2 Receiver 3 Supervised o 3 Heartbeat 1 o4 Cell Primary R6 Remote Firmw...

Page 226: ...nge 00000 65535 018 Receiver Group Pair Default 0000 Valid range 0000 FFFF 020 Time Zone Default 00 Valid range 00 99 Reporting codes 025 Radio Activation Restore Default FF Program 00 disable or FF enable 026 Receiver 1 Test Transmission Default FF Program 00 disable or FF enable 027 Receiver 2 Test Transmission Default 00 Program 00 disable or FF enable 028 Receiver 3 Test Transmission Default F...

Page 227: ...Default 0000000000 Valid range 0000000001 FFFFFFFFFE 102 Receiver 1 DNIS Default 000000 Valid range 000000 FFFFFF 103 Receiver 1 IP Address Default 127 000 000 001 104 Receiver 1 UDP Remote Port Default 03061 Valid range 00000 65535 105 Receiver 1 UDP Local Port Default 03060 Valid range 00000 65535 106 Receiver 1 Domain Name Default 32 ASCII characters Ethernet receiver 2 configuration 111 Receiv...

Page 228: ...03 Receiver 3 IP Address Default 000 000 000 000 204 Receiver 3 Port Default 03061 Valid range 00000 65535 205 Receiver 3 APN Default 32 ASCII characters 206 Receiver 3 Domain Name Default 32 ASCII characters Cellular receiver 4 configuration 211 Receiver 4 Account Code Default 0000000000 Valid range 0000000001 FFFFFFFFFE 212 Receiver 4 DNIS Default 000000 Valid range 000000 0FFFFF 213 Receiver 4 ...

Page 229: ...255 229 Voice Call Back Number Default 32 digit phone number Valide entries 000000000000000 to FFFFFFFFFFFFFFF Integration session 1 422 Integration Identification Number Default MAC IMEI Read only 423 Session 1 Integration Access Code Default 12345678123456781234567812345678 Valid range 00000000000000000000000000000000 FFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFF 424 Session 1 SMS Label Default 11111111 16 A...

Page 230: ...3 Session 1 Integration Incoming Port Default 03071 Valid range 00000 65535 Integration sessions 2 4 450 460 Repeats 423 433 for Session 2 477 487 Repeats 423 433 for Session 3 504 514 Repeats 423 433 for Session 4 Notification controls 691 Session 1 Notification Control R1 Alarm and Alarm Restore Notifications R2 Tamper and Tamper Restore Notifications R3 Arming and Disarming Notifications R4 Tro...

Page 231: ...arm and Alarm Restore Notifications R2 Tamper and Tamper Restore Notifications R3 Arming and Disarming Notifications R4 Trouble and Trouble Restore Notifications R5 Test Transmission Notifications R6 Reserved R7 Reserved R8 Reserved Receiver test 901 Receiver Test o1 Receiver 1 o2 Receiver 2 o3 Receiver 3 o4 Receiver 4 o6 Reserved o6 Reserved o7 Reserved o8 Reserved Radio diagnostics 976 Configura...

Page 232: ...for DLS and Firmware upgrades 997 IMEI Number 998 MAC Address 6 19 Keypad Programming 860 Display Keypad Slot Number Description on page 147 861 876 Keypad Programming Refer to the installation instructions provided with the keypad for details 000 Keypad Partition Mask 00 Global 01 R Partition 1 05 o Partition 5 02 o Partition 2 06 o Partition 6 03 o Partition 3 07 o Partition 7 04 o Partition 4 0...

Page 233: ... Pulse Time Minutes Default 00 minutes Pulse Time Seconds Default 05 seconds 021 Keypad Option 1 For systems compliant with EN50131 1 and EN50131 3 Section 021 options 1 and 2 must be OFF 2 digit decimal 1 R F Key Enabled EN 2 R R M Key Enabled 3 R R P Key Enabled 4 R Display Code or X s 022 Keypad Option 2 1 R Local Clock Display 2 o Local Clock 24 Hour 3 R Auto Alarm Scroll 5 R Power LED 6 R Pow...

Page 234: ... ____ 28 ____ 46 ____ 64 ____ 82 ____ 100 ___ 118____ 136____ 154____ 172 ____190 ____208 ____ 226____ 244 ____ 11 ____ 29 ____ 47 ____ 65 ____ 83 ____ 101 ___ 119____ 137____ 155____ 173 ____191 ____209 ____ 227____ 245 ____ 12 ____ 30 ____ 48 ____ 66 ____ 84 ____ 102____ 120____138____ 156____ 174 ____192 ____210 ____ 228 ____246 ____ 13 ____ 31 ____ 49____ 67_____ 85 ____ 103____ 121____139____...

Page 235: ...ment 003 Edit Module Slot Assignment 101 Delete Keypads 102 Delete HSM2108 8 Zone Module 103 Delete HSM2208 8 Output Module or High Current O P 104 Delete HSM3408 8 I O Expansion Module 106 Delete HSM2Host 108 Delete HSM2955 109 Delete HSM2300 Power Supply 1A 110 Delete HSM2204 4 High Current Output 111 Delete HSM3350 3A Power Supply Module 112 Delete HSM3204CX Corbus Repeater 903 Confirm Modules ...

Page 236: ...urrent Output Battery 001 to 004 551 554 3 A Power Supply 001 to 004 601 608 Corbus repeater 001 to 008 912 Zone Soak Test Description on page 152 000 Zone Soak Test Duration 3 digit decimal 001 255 Days Default 014 001 Zone Soak Test Assignment Zones 1 8 002 Zone Soak Test Assignment Zones 9 16 003 Zone Soak Test Assignment Zones 17 24 004 Zone Soak Test Assignment Zones 25 32 005 Zone Soak Test ...

Page 237: ...e Soak Test Assignment Zones 225 232 030 Zone Soak Test Assignment Zones 233 240 031 Zone Soak Test Assignment Zones 241 248 6 24 Battery Settings 982 Battery Settings Description on page 152 000 Panel Battery Settings 01 o Panel High Charge Current 010 HSM2204 High Current Output Battery 01 o HSM2204 1 High Charge Current 02 o HSM2204 2 High Charge Current 03 o HSM2204 3 High Charge Current 04 o ...

Page 238: ... 3 Battery Settings 003 01 o HSM3350 Battery 1 High Charge 02 o HSM3350 Battery 2 High Charge 03 RHSM3350 Battery 2 Enable 040 HSM3350 Module 4 Battery Settings 004 01 o HSM3350 Battery 1 High Charge 02 o HSM3350 Battery 2 High Charge 03 RHSM3350 Battery 2 Enable 6 25 Restoring Factory Defaults 989 Default Master Code 990 Installer Lockout Enable Disable 991 Default Keypads 999 Default All Keypads...

Page 239: ... jam detected 03 Loss of clock 04 Output 1 fault 05 Warm start 06 USB Wi Fi Connected 07 Power Unit Fail System 08 Power Unit Failure HSM3204CX Corbus Repeater 09 Power Unit Failure HSM3350 3 A Power Supply 10 Overcurrent 02 Module Low Battery 01 Panel low battery 02 Panel no battery 04 HSM2204 1 4 low battery 05 HSM2204 1 4 no battery 07 HSM2300 1 4 low battery 08 HSM2300 1 4 no battery 10 HSM320...

Page 240: ...3 HSM3350 11 Communications 01 TLM 02 FTC Receiver 1 4 04 Alt comm cellular 05 Alt comm Ethernet 06 Receiver 1 4 absent 07 Receiver 1 4 supervision 09 Alt comm fault 10 Alt comm FTC trouble 12 Not Networked 01 Zone 1 248 02 Keypad 1 16 03 Siren 1 16 04 Repeater 1 8 05 User 1 32 13 AUX Trouble 05 HSM2300 06 HSM2204 07 System area 10 HSM3408 11 HSM3204CX 12 HSM3350 AUX 1 trouble 13 HSM3350 AUX 2 tro...

Page 241: ...nit Failure HSM3350 A fault with the internal power supply has been detected on the 3A power supply Ensure the combined output power of the 3A power supply module is not exceeding 3A Power cycle the module and if the trouble persists it may indicate a permanent hardware failure 10 Overcurrent The combined output power on the panel has exceeded 2A for a period of more than 5 minutes Reduce the load...

Page 242: ...M3204CX no battery Enter 11 to view which HSM3204CX does not have a battery connected Verify voltage measured across DC input terminals is 16 18 VAC Replace HSM65W power supply adapter if required Connect battery remove AC power Verify measured voltage across Aux terminals is 12 5VDC min Replace battery if it is no longer able to hold a charge due to age 13 HSM3350 low battery 1 Enter 13 to view w...

Page 243: ...age Enter 04 to view zone expanders with a bus voltage of less than 5 9V 05 HSM2300 Bus Low Voltage Enter 05 to view power supplies with a bus voltage of less than 6 9V 06 HSM2204 Bus Low Voltage Enter 06 to view high current output modules that have detected a bus voltage of less than 6 9V 07 Panel Corbus Fault The panel has detected that its corbus output voltage is less than 9 0V or higher than...

Page 244: ...C 06 HSM2204 1 4 AC 07 Alarm Controller 08 HSM3204CX AC 09 HSM3350 AC An AC trouble has been detected on a device or module Verify voltage measured across DC input terminals is 16 20VDC Replace HSM65W power adapter if required For the HSM2204 or HSM2300 modules ensure a 40VA 16 5VAC transformer is being used Terminal voltage should be 16 17VAC Replace transformer if required 244 ...

Page 245: ...d re locate if needed 06 Device mask Enter 06 to view the zone label in masking condition A zone programmed as 24H Anti Masking or a wireless device has detected a masking condition with one of its sensors Refer to the device manual to troubleshoot conditions that may cause masking detection for that devices sensors 08 Heat trouble Enter 10 to view the wireless zone which is detecting low temperat...

Page 246: ...e or more zones with DEOL or TEOL resistors enabled Check that the tamper switch is securely attached to the wall Remove the wire leads from I O and COM and measure the resistance of the wire leads Connect a 5 6K resistor Green Blue Red across the I O and COM terminals Verify the trouble condition clears A tamper condition is present on one or more wireless devices Ensure device cover is secure En...

Page 247: ...ly activating the tamper switch if present Ensure for the Keypads that the rubber tamper plunger is installed on the back plastics and that the keypad is securely closed and fastened to the wall For the HSM2HOST ensure module is securely closed and correctly mounted for wall tamper operation Manually trip then restore the tamper If tamper condition persists replace the module Trouble 11 Communicat...

Page 248: ...ports open default UDP port 3060 and port 3065 Ensure that all cellular receiver APNs have been programmed with the access point name provided by the cellular provider If Common Mode is used and only one path is initiliazed while the other path is not successful generate a manual test transmission over both paths or power cycle the communicator to recover the Receiver Not Available trouble 07 Rece...

Page 249: ... firmware is compatible with PSP firmware to support extended number of Zones and Partitions Interactive Zone trouble is generated when the Alarm com firmware does not support the configured number of zones in panel 220 Zones and Interactive Partition Trouble is generated when the Alarm com firmware does not support configured number of Partitions Ensure to configure compatible number of zones and...

Page 250: ... ID SIA Zone Alarm Restore Event Codes on page 255 for details 307 Zone Restores A R 307 Zone tamper restore MA R E 3 83 ZZZ R 3 83 ZZZ TA ZZZ TR ZZZZ 307 Zone fault restore MA R E 3 8A ZZZ R 3 8A ZZZ UT ZZZZ UJ ZZZZ Tamper Events 308 101 Keypad 1 16 tamper restore alarm T R E 3 83 601 616 R 3 83 601 616 TA 0601 0616 TR 0601 0616 308 101 Siren 1 16 tamper restore alarm T R E 3 83 801 816 R 3 83 80...

Page 251: ...nel MA R E 3 A2 000 R 3 A2 000 YT 0000 YR 0000 308 301 Battery absent trouble restore Main panel MA R E 3 11 000 R 3 11 000 YM 0000 YR 0000 308 301 Power unit failure trouble restore MA R E 3 14 000 R 3 14 000 YP 0000 YQ 0000 308 301 Panel AC trouble restore Main panel MA R E 3 A1 000 R 3 A1 000 AT 0000 AR 0000 308 302 Bell circuit trouble restore MA R E 3 21 000 R 3 21 000 YA 9999 YH 9999 308 302...

Page 252: ...21 624 308 332 HSM3408 Aux Supply 1 30 trouble restore MA R E 3 12 301 330 R 3 12 301 330 YI 0301 0330 YJ 0301 0330 308 332 HSM3204CX Aux Supply 1 8 trouble restore MA R E 3 12 801 808 R 3 12 801 808 YI 0801 0808 YJ 0801 0808 308 332 HSM3204CX Corbus output 1 8 trouble restore MA R E 3 12 801 808 R 3 12 801 808 YI 0801 0808 YJ 0801 0808 308 332 HSM3350 Aux Supply 1 4 trouble restore MA R E 3 12 65...

Page 253: ... MA R E 3 AA 001 R 3 AA 001 YX 0001 YZ 0001 308 351 Receiver X FTC Restoral MA R R 3 54 00X YK 000X On Board Communicator 851 025 Radio activation restore N A R 5 52 001 RS 0001 851 226 Ethernet Receiver 1 Test Transmission N A E 6 A3 951 RP 0001 851 227 Ethernet Receiver 2 Test Transmission N A E 6 A3 952 RP 0002 851 228 Cellular Receiver 3 Test Transmission N A E 6 A3 955 RP 0003 851 229 Cellula...

Page 254: ...iry of alarm cancellation timer A R E 4 A6 UUU OC UUUU 308 011 PGM2 Silent 24 Hour Input Aux Input Alarm restore A R E 1 46 992 R 1 46 992 UA 0992 UH 0992 308 011 PGM2 Audible 24 Hour Input Aux Input Alarm restore A R E 1 4A 992 R 1 4A 992 UA 0992 UH 0992 308 305 PGM2 2 Wire Smoke Alarm Restore A R E 1 11 992 R 1 11 992 FA 0992 FH 0992 Priority Alarm and Restoral Events 308 011 F Key alarm restore...

Page 255: ...ut Installer Programming has been exited MA R E 6 28 000 LS 0000 308 313 Panel firmware update begin successful MA R E 9 01 900 R 9 01 900 LB 0900 LS 0900 308 313 Panel firmware update fail MA R E 9 02 900 LU 0900 308 321 Panel power unit fail restore MA R E 3 14 000 R 3 14 000 YP 000 YQ 000 A R alarms restores T R tampers restorers O C openings closings MA R maintenance alarms restores T test tra...

Page 256: ...tained Keyswitch Arm Walk Test Only BA ZZZZ BH ZZZZ E 1 3A ZZZ R 1 3A ZZZ Momentary Keyswitch Disarm Walk Test Only BA ZZZZ BH ZZZZ E 1 3A ZZZ R 1 3A ZZZ Maintained Keyswitch Disarm Walk Test Only BA ZZZZ BH ZZZZ E 1 3A ZZZ R 1 3A ZZZ 24 Hr Supervisory US ZZZZ UR ZZZZ E 1 5A ZZZ R 1 5A ZZZ 24 Hr Supervisory Buzzer UA ZZZZ UH ZZZZ E 1 5A ZZZ R 1 5A ZZZ 24 Hr Auto Verified Fire Wireless FA ZZZZ FH Z...

Page 257: ...Interior 099 Intrusion 100 Invalid 101 Is 102 Key 103 Kids 104 Kitchen 105 Latchkey 106 Laundry 107 Left 108 Level 109 Library 110 Light 111 Lights 112 Living 113 Load 114 Loading 115 Low 116 Lower 117 Main 118 Master 119 Mat 120 Medical 121 Memory 122 Menu 123 Monoxide 124 Mother s 125 Motion 126 No 127 North 128 Not 129 Now 130 Number 131 Off 132 Office 133 OK 134 On 135 Open 136 Opening 137 Pan...

Page 258: ...8 Standard 24Hr Fire Wireless Refer to 001 Zone types on page 78 for details Digit 2 System EOL Configuration Options Option 13 bit 1 13 bit 2 1 NC Loops ON OFF 2 SEOL OFF OFF 3 DEOL OFF ON Digit 3 Reporting Code Communication Options Entry Template Programming 1 Disabled 380 Comm Toggles 1 Bit 1 Communications Enabled Off 2 Receiver 1 and 2 SIA with Backup 380 Comm Toggles 1 Bit 1 Communications ...

Page 259: ...00 Comm Path 002 Receiver 2 01 PSTN 300 Comm Path 003 Receiver 3 01 PSTN 300 Comm Path 004 Receiver 4 01 PSTN 4 Receiver 1 SIA 380 Comm Toggles 1 Bit 1 Communications Enabled On 350 Communicator Formats 001 Receiver 1 04 SIA 350 Communicator Formats 002 Receiver 2 04 SIA 350 Communicator Formats 003 Receiver 3 04 SIA 350 Communicator Formats 004 Receiver 4 04 SIA 381 Comm Toggles 2 Bit 2 Bell Ring...

Page 260: ...380 Comm Toggles 1 Bit 1 Communications Enabled On 350 Communicator Formats 001 Receiver 1 03 CID 350 Communicator Formats 002 Receiver 2 03 CID 350 Communicator Formats 003 Receiver 3 03 CID 350 Communicator Formats 004 Receiver 4 03 CID 384 Comm Backup Bit 2 Receiver 2 Backup On 384 Comm Backup Bit 2 Receiver 2 Backup Off 384 Comm Backup Bit 2 Receiver 2 Backup Off 300 Comm Path 001 Receiver 1 0...

Page 261: ...eceiver 2 Off 309 001 Maintenance Bit 3 Receiver 3 Off 309 001 Maintenance Bit 4 Receiver 4 Off Test transmission call directions disabled 309 002 Test Transmission Bit 1 Receiver 1 Off 309 002 Test Transmission Bit 2 Receiver 2 Off 309 002 Test Transmission Bit 3 Receiver 3 Off 309 002 Test Transmission Bit 4 Receiver 4 Off l Enables Disables all Reporting Codes l Selected Troubles Enables the fo...

Page 262: ... On 308 202 Bit 3 Automatic Cancel On l Zone Alarm Restore Group Disables all zone alarm restore reporting codes Zone Alarm Restore Group DLS Installer Lead In Out Programming Restore zone alarm reporting codes 307 001 Bit 2 Alarm Restore Off 307 002 Bit 2 Alarm Restore Off 307 003 Bit 2 Alarm Restore Off 307 004 Bit 2 Alarm Restore Off 307 005 Bit 2 Alarm Restore Off 307 006 Bit 2 Alarm Restore O...

Page 263: ...your entry ii This account code is entered into programming section 310 001 4 DLS Access Code 6 digit code i Program the required DLS access code All 6 digits must be entered in order to complete your entry ii This access code is entered into programming section 403 5 Entry Delay 1 and Exit Delay i Enter the 3 digit entry delay 1 in seconds followed by the desired 3 digit exit delay in seconds The...

Page 264: ...8 109 110 111 112 113 114 115 116 117 118 119 120 121 122 123 124 125 126 127 160 ֻ ヲ ア ィ ゥ ェ ォ カ ュ ョ シ ア イ ゥ ェ ォ カ キ ク 161 162 163 164 165 166 167 168 169 170 171 172 173 174 175 176 177 178 179 180 181 182 183 184 ケ コ サ シ ス セ ソ タ ダ ツ テ ト ナ ニ ヌ ネ ノ ハ ヒ フ ヘ ホ マ ミ 185 186 187 188 189 190 191 192 193 194 195 196 197 198 199 200 201 202 203 204 205 206 207 208 ム メ モ ヤ ユ ョ ラ リ ル レ ロ ワ ン α ä β Ɛ μ σ ρ ...

Page 265: ...t this equipment to the premises wiring and telephone network must comply with the applicable FCC Part 68 rules and requirements adopted by the ACTA A compliant telephone cord and modular plug is provided with this product It is designed to be connected to a compatible modular jack that is also compliant See installation instructions for details Ringer Equivalence Number REN The REN is used to det...

Page 266: ...s of all devices does not exceed five HS3032 Registration number IC 160A HS3256 HS3128 Registration number IC 160A HS3256 HS3248 Registration number IC 160A HS3256 L indice d équivalence de la sonnerie IES sert à indiquer le nombre maximal de terminaux qui peuvent être raccordés à une interface téléphonique La terminaison d une interface peut consister en une combinaison quelconque de dispositifs ...

Page 267: ...r ULC Residential Commercial installations set for daily test transmission l For UL Residential Fire installations 2 requires code shall be enabled Section 023 option 5 ON and latching troubles shall be enabled Section 019 option 2 ON l If a repeater is needed two repeaters model PG9920 shall be used to ensure proper signal routing l Wireless Supervision window shall be set to 4 hours for Fire Ins...

Page 268: ...ng Installations l For installation requirements levels of security communication modules and configurations Refer to the ULC Installation Guide for PowerSeries Pro P N 29010346 l HS2TCHPRO BLK touch screen keypad is for supplementary use only with ULC Commercial Fire Monitoring l For Commercial Fire monitoring the primary power failure transmission may be delayed up to 3h and Bell shall be disabl...

Page 269: ...hout causing an alarm will require that all partitions be disarmed l In all cases described above the protected area for the control unit must be programmed as not bypassable Casual Users The installer should caution the user not to give system information e g codes bypass methods etc to casual users e g service people and to only give out One Time Use codes User Information The installer should a...

Page 270: ...ne Control unit model HS3032 HS3128 or HS3248 and any one of the compatible listed keypads refer to Model comparison The following wireless keyfobs can also be used in SIA compatible installations PG9929 PG9939 PG9949 Note For models PG9929 and PG9939 the panic emergency key shall be disabled for SIA compliant installations For a list of the default values programmed when the unit is shipped from ...

Page 271: ...y to stay arm the system When away arming audible exit beeps can not be disabled For remote arming using keyfob it is possible to program the instant stay arm no exit delay By default this option is OFF When arming disarming with keyfob the bell squawk option shall be enabled The Bell shall be tested daily Alternate option is to have bell squawk enabled for arming disarming Default Enabled Allowed...

Page 272: ...lt Disabled Walk Test Start End Reporting Codes 308 401 options 1 and 2 Access to the reporting codes for walk test start and end times Duress Code Duress codes function the same as user access codes except they transmit a duress reporting code when used to perform any function on the system Duress codes cannot be used to access 5 6 or 8 menus Duress codes are created by the master user or supervi...

Page 273: ...pliant installations the following functions must be disabled Fire Alarm CO Alarm Auxiliary Medical Alarm functions In Section 861 21 options 1 and 2 must be off For EN50131 compliant installations the following zone types must not be used 007 Delayed 24 Hour Fire 041 24 Hour CO 049 24 Hour Flood 008 Standard 24 Hour Fire 045 24 Hour Heat 052 24 Hour Non Alarm 025 Auto Verified Fire 046 24 Hour Me...

Page 274: ...on the supervison must be set to 30 minutes This product is in conformity with the Electromagnetic Compatibility Directive 2014 30 EU the Low Voltage Directive 2014 35 EU and the RoHS3 Directive EU 2015 863 The product is labelled with the CE mark as proof of compliance with the above mentioned European Directives Also a CE declaration of conformity DoC for this product can be found at www dsc com...

Page 275: ...nditions separately to the HS3032 HS3128 and HS3248 The HS3032 HS3128 and HS3248 are capable of supporting the completion of the full setting procedure by one of the fol lowing methods a push button switch mounted outside the supervised premises Instructions to be provided for the zone type to be pro grammed for the key arming or b protective switch i e door contact fitted to the final exit door o...

Page 276: ...ommunicator and or plug in cellular module models LE 3G 3H9080 DACT Passive Level P1 PSDN Passive P1 3 Active A1 4 use with Internal Ethernet communicator and or plug in cellular module models LE 3G 3H9080 DACT PSDN Passive PSDN Active use with Internal Ethernet communicator and or plug in cellular module models LE 3G 3H9080 25 25 30 30 PG9926 PG9916 Smoke Detector Circuit zone Control Unit Delay ...

Page 277: ...se with same type 20 mm rated 250V 3 15A Slow Blow STANDOFF PC BOARD Cable tie required 1 Insert standoff into cabinet mounting hole in the desired location The standoff makes an audible click when properly inserted 2 Position circuit board mounting holes over standoffs Press firmly on board to snap in place Use metal standoff and screw in the position indicated IMPORTANT Ensure screw and standoff...

Page 278: ...line SEOL Double end of line DEOL or Triple end of line TEOL Observe the following guidelines Note For UL Listed Installations use SEOL or DEOL only Minimum 22 AWG wire maximum 18 AWG Do NOT use shielded wire Wire run resistance shall not exceed 100Ω refer to the chart below Wire Gauge Maximum Wiring Length to End of Line Resistor feet meters 22 3000 914 20 4900 1493 19 6200 1889 18 7800 2377 278 ...

Page 279: ...ne Definition Section 013 Opt 1 Selects Normally Closed or EOL resistors Section 013 Opt 2 Selects Single EOL or Double EOL resistors Zone status loop resistance status Loop Status Loop Resistance SEOL standard SEOL Fire DEOL TEOL Fault Infinite 0Ω 15 600Ω Secure 5600ΩΩ 5600Ω 5600Ω 5600Ω Tamper Infinite Infinite Violated 0Ω Infinite 0Ω 11 200Ω 11 200Ω Masking 21 200Ω 6 5 Bell wiring These terminal...

Page 280: ...dc 14 Vdc 6 7 Corbus wiring The RED and BLK Corbus terminals are used to provide power while YEL and GRN are used for data communications The 4 Corbus terminals of the alarm controller must be connected to the 4 Corbus terminals or wires of each module The following conditions apply l Corbus should be run with 18 to 22 AWG quad two pair twisted preferred l The modules can be home run to the panel ...

Page 281: ...ut Note Use only SEOL resistors on FIRE ZONES 2 wire smoke detectors initiating circuit l Style B Class B Supervised Power Limited l Compatibility Identifier HS3 1 l DC Output Voltage 9 4 13 8 VDC l Detector Load 2 mA MAX l Single end of line SEOL Resistor 2200Ω l Loop Resistance 24Ω MAX l Standby Impedance 1250Ω NOM l Alarm Impedance 664Ω MAX l Alarm Current 97 mA MAX l Maximum number of 2 wire S...

Page 282: ...d insulated green wire connect the earth ground terminal on the HS65WPSx power adapter to the earth ground screw and nut assembly as shown in the diagram The earth ground screw and nut assembly must be mounted to the cabinet to one of the designated holes marked with the earth ground symbol Figure 6 3 Earth ground installation 1 3 4 5 2 6 Item Description 1 Nut 2 Earth ground connection from build...

Page 283: ... three as per ISO8201 and temporal four CO alarm output l Warning device sounds alarms in the following priority fire CO burg Note For NFA2P certified systems the delay for operating the warning device shall be set to max 10 min Memory l CMOS EEPROM memory l Retains programming and system status on AC or battery failure for 20 years min not verified by UL Power Supply North America l Power Supply ...

Page 284: ...n threshold 11 3 VDC l Battery restore voltage 12 5 V l Main board current draw battery only l HS3032 HS3128 HS3248 no alternate communicator standby 100 mA DC l HS3032 HS3128 HS3248 including plug in communicator standby 120 mA DC l Self reseting FETs for short overcurrent protection on the circuit board l Internal clock locked to the internal Real Time Clock The standby battery does not automati...

Page 285: ...emains on for 30 seconds When the system is in the set state opening the door to the entry exit route ini tiates the entry procedure The system is unset using a valid user access code or an enrolled compatible keyfob l The alarm system does not support prioritization for indications l Masking signals are processed as intruder signals 7 1 Locating detectors and escape plan The following information...

Page 286: ...ection of a fire and the time it becomes deadly It is thus very important that a family escape plan be developed and rehearsed 1 Every family member should participate in developing the escape plan 2 Study the possible escape routes from each location within the house Since many fires occur at night special attention should be given to the escape routes from sleeping quarters 3 Escape from a bedro...

Page 287: ...ely in the air CO detectors can measure the concentration and sound a loud alarm before a potentially harmful level is reached The human body is most vulnerable to the effects of CO gas during sleeping hours therefore CO detectors should be located in or as near as possible to sleeping areas of the home For maximum protection a CO alarm should be located outside primary sleeping areas or on each l...

Page 288: ...unauthorized attachment alterations modifications or foreign objects l damage caused by peripherals unless such peripherals were supplied by Digital Security Controls Ltd l defects caused by failure to provide a suitable installation environment for the products l damage caused by use of the products for purposes other than those for which it was designed l damage from improper maintenance l damag...

Page 289: ... as expected for a variety of reasons Some but not all of these reasons may be Inadequate Installation A security system must be installed properly in order to provide adequate protection Every installation should be evaluated by a security professional to ensure that all access points and areas are covered Locks and latches on windows and doors must be secure and operate as intended Windows doors...

Page 290: ...d by these beams They cannot detect motion which occurs behind walls ceilings floor closed doors glass partitions glass doors or windows Any type of tampering whether intentional or unintentional such as masking painting or spraying of any material on the lenses mirrors windows or any other part of the detection system will impair its proper operation Passive infrared motion detectors operate by s...

Page 291: ... treaties as well as other intellectual property laws and treaties The SOFTWARE PRODUCT is licensed not sold 1 GRANT OF LICENSE This EULA grants You the following rights a Software Installation and Use For each license You acquire You may have only one copy of the SOFTWARE PRODUCT installed b Storage Network Use The SOFTWARE PRODUCT may not be installed accessed displayed run shared or used con cu...

Page 292: ...nd the parties agree to be bound by the arbitrator s decision The place of arbitration shall be Toronto Canada and the installation manual of the arbitration shall be English 7 LIMITED WARRANTY a NO WARRANTY DSC PROVIDES THE SOFTWARE AS IS WITHOUT WARRANTY DSC DOES NOT WARRANT THAT THE SOFTWARE WILL MEET YOUR REQUIREMENTS OR THAT OPERATION OF THE SOFTWARE WILL BE UNINTERRUPTED OR ERROR FREE b CHAN...

Page 293: ...he entire system be completely tested on a regular basis However despite frequent test ing and due to but not limited to criminal tampering or electrical disruption it is possible for this SOFTWARE PRODUCT to fail to perform as expected 293 ...

Page 294: ...osecution wherever necessary All trademarks not owned by Tyco are the property of their respect ive owners and are used with permission or allowed under applicable laws Product offerings and specifications are subject to change without notice Actual products may vary from photos Not all products include all features Availability varies by region contact your sales representative 2018 Tyco Security...

Reviews: