Section 5: Programming
Note:
With audible alarm active, using the keyswitch when disarmed is the same as entering an access code at the keypad.
Using the keyswitch during the first 30 seconds of a delayed fire alarm is the same as pressing a key at the keypad (the 90
second delay starts). Activation of a keyswitch zone arms or disarms the system. Activation of this zone type is NOT logged
nor is the Police code transmitted. Bypassed zones of this type are not un-bypassed when the system is disarmed. When the
zone is bypassed, a zone bypass event buffer log and communication occurs immediately, NOT when the system is armed.
*Keyswitch module not for use in UL/ULC listed installations.
067
–
Maintained Keyswitch Arm
Often used with a keyswitch module, turning the key (open state) arms the system. Turning the key back (restored state) dis-
arms the system. Tampers and faults only initiate their respective trouble sequence.
Note:
DO NOT use for wireless zones. Activation of the zone does not log or transmit the Police code. Bypassed zones of
this type are not un-bypassed when the system is disarmed. When the zone is bypassed, a zone bypass event buffer log and
communication occurs immediately, NOT when the system is armed.
With an audible alarm active, using the keyswitch when disarmed is the same as entering an access code at the keypad.
Activating this zone type during the first 30 seconds of a delayed fire alarm is the same as pressing a key at the keypad (the
90 second delay starts). If left in the open state, the system does not arm until the zone is restored and tripped again.
068
–
Momentary Keyswitch Disarm
Use with a keyswitch module. Activating and restoring this zone disarms the partition and silences alarms. Tampers or faults
do not disarm the zone.
Note:
Do not use as a global zone.
069
–
Maintained Keyswitch Disarm
Used with a maintained keyswitch. Activating this zone disarms the partition.
Tampers or faults on this zone do not disarm the partition.
071
–
Doorbell Zone
This zone type sounds a chime through keypads on the partition when activated. No alarms are generated. Various chime
tones can be programmed. Disabling door chime on the partition also disables the chime on this zone.
Note:
Do not use as a global zone.
072
–
Push to Set (Non CP-01 panels only)
Activating this zone starts an infinite exit delay when armed according to the methods described in the table below. To com-
plete the arming sequence, this zone must be activated and restored. Once done, the exit delay timer starts.
Arming method
Infinite exit delay
Arming mode
User code
Y
Away
Keyswitch
Y
Away
Away key
Y
Away
*0 arm
Y
Away
*9 arm
N
Stay
Stay key
N
Stay
Night key
N
Night
Remote access/SMS
-
Do not use
DLS arm
N
Away
No activity arming
N
Away
Note:
Do not use exit delay termination with this zone type. Away arming with this zone bypassed prevents arming.
If you silence a fire alarm by entering a user code, and the zones that imitated the fire alarm remain open, a Bells Silenced
message displays. The system automatically clears the message when all the fire zones are restored on the system. When
the Bells Silenced message displays, a user can still view all standard base menu messages.
Note:
The Bells Silenced message also overrides the automatic display of the Alarm Memory feature for fire alarms.
[002] Zone attributes
Zone attributes are used to customize the operation of zones. When a zone type (section [001]) is programmed, the default
zone attribute is automatically assigned.
Note:
These attributes override default settings. Do NOT change fire zone attributes from their default settings.
- 82 -