![background image](http://html.mh-extra.com/html/johnson-controls/hs3032/hs3032_reference-manual_2023753071.webp)
Section 4: System operation
[*][0] quick arm/exit
This feature operates differently depending on whether or not the alarm system is armed or disarmed.
Note:
This feature shall not be used for EN50131 certified systems.
When disarmed:
Pressing [*][0] arms the alarm system without having to enter an access code. This provides a fast method of arming for reg-
ular users and allows users without an access code to arm the system.
Note:
The Quick Arm feature (section [015] option 4) must be enabled in order for this function to operate as intended. Func-
tion keys also will not require an access code when this option is enabled.
When armed:
This feature provides a means to exit the premises while the alarm system is armed without having to disarm then rearm it.
Pressing [*][0] starts a 2-minute timer that enables any door programmed as a delay zone to be opened and closed once
without triggering an alarm.
If the door is not closed at the end of the 2-minute timer, the entry delay sequence begins. Any additional activity on another
zone triggers the associated alarm or delay sequence.
4.8 Visual verification
This feature enables the central station operator to view captured images of the premises in the event of an alarm event.
Combination camera/motion detectors can be installed throughout the premises to provide visual verification coverage. The
microphone on the camera PIR can be disabled.
Visual verification sessions are triggered by the following:
l
Fire key
l
Medical key
l
Panic key
l
Alarms detected by armed PIR Cameras
To set up visual verification on a partition:
l
Enroll the camera PIR; [804]
l
Set visual verification options; [804]>[841]:
l
[001] Visual Verification Enable/Disable
l
[002] View Time Window
l
[003] View Other Alarms
l
Input a custom label to identify the camera PIR; [000]>[001]
l
Enable this option on the alternate communicator (in [851]>[010] option 2).
Refer to the Camera PIR installation manual for more details.
Note:
Visual Verification has not been evaluated by UL and shall be disabled for UL certified installations.
Note:
While an image is being transferred from the PIR camera to a central station receiver, the product cannot capture addi-
tional images.
- 71 -