• Away arm the system
• Night arm the system
• Disarm the system
• Activate/deactivate command output 1-4
• System status request
• Alarm memory request
• Zone bypass
• Zone unbypass
SMS text messages must be formatted as follows:
<function name><space><partition #><space><access code>
e.g., Stay Arm partition 1 1234
Once the command is received and executed by the alarm system, the user receives a confirmation
text message.
Note:
Do not use Away Arm if Push to Set [001][072] or Final Door Set [001][016] zones are
programmed.
Visual Verification
Allows the monitoring station to use video clips captured from system motion cameras for
verification of any alarms.
Note:
This is a supplementary feature that has not been investigated by UL/ULC.
Note:
Must be enabled and configured by installer.
System Operation
Programming
How to Program
This section describes how to view alarm system programming options using the supported keypad
types.
Programming Methods
The alarm system can be programmed using the following methods:
PowerSeries Neo HS2016/HS2016-4/HS3032/HS2064/HS2064 E/HS2128/HS2129 E Alarm Controller Reference
Manual
72