wireless transceiver HSM2HOST or an RF keypad must be enrolled first before wireless devices can
be enrolled.
Enrolling Modules
During automatic and manual enrollment, if an attempt is made to enroll more than the maximum
number of modules, an error tone sounds and a message is displayed on LCD keypads.
Table 15: Module Capacity
Module
HS2016-4
HS2016
HS2032
HS2064/ HS2064E HS2128/HS2128E
HSM2108 8 Zone
expander
1
1
3
7
15
HSM2208 8 Output
expander
2
2
4
8
16
HS2LCD(P)X
HS2ICN(P)X
HS2LCDWF(P)(V)X
8
8
8
8
16
HS2TCHP
Touchscreen
Keypad
8
8
8
8
16
HSM2300 Power
Supply 1A
3
3
3
3
4
HSM2204 4 High-
current Output
1
1
1
3
4
Transceiver:
HSM2HOSTx
Keypads:
HS2LCDRF(P)X
HS2ICNRF(P)X
1
1
1
1
1
HSM2955
(not UL evaluated)
1
1
1
1
1
Modules can be enrolled automatically or manually using section [902] of Installer programming.
For instructions on enrolling modules,
.
To confirm that a module has been successfully enrolled, use Installer Programming section [903].
Enrolling the First Keypad
To enroll a hardwired keypad, connect the keypad to the alarm controller, power up the alarm panel
then press any button on the keypad.
To enroll a wireless keypad, first connect the HSM2HOSTx wireless integration module to the alarm
controller. Next, power up the alarm panel and a wireless keypad. Press any button on the keypad
to enroll it on the HSM2HOSTx. The HSM2HOSTx is then enrolled on the alarm panel. To enroll other
keypads,
.
Module Supervision
By default, all modules are supervised upon installation. Supervision is enabled at all times so that
the panel can indicate a trouble if a module is removed from the system.
To check which modules are currently connected and supervised,
.
If a module is connected but is not recognized by the system, it may be due to any of the following
reasons:
• the module is incorrectly wired to the alarm controller
• the module has exceeded its maximum wire run length
41