OFF: Regardless of other 2-way audio programming, 2-way audio sessions cannot be initiated over
receiver 4.
DLS Programming
Downloading allows programming of the entire alarm system via a computer. All functions and
features, changes and status, such as trouble conditions and open zones, can be viewed or
programmed by downloading.
The following downloading options are available:
• 6-hour window on start up: When the alarm system is powered up, downloading access is
available for 6 hours. This provides the option of downloading without having to complete any
keypad programming.
• Double call method: The installer initiates a downloading window by calling the alarm system,
hanging up, then calling back again.
• User enabled DLS window: The user initiates a downloading window using [*][6][Master code]
[05]. This can be a 6-hour window where the installer initiates and terminates downloading as
many times as necessary, or it can be a 1-hour, 1 use window.
• User initiated call-up: the user can initiate a downloading session using [*][6][Master Code]
[06].
• On-site downloading using PC-Link: The installer connects a computer directly to the alarm
system to perform on-site downloading.
• Auto event buffer upload: The Event buffer is automatically uploaded to the DLS/SA computer
when it reaches 75% full.
Refer to the DLS/SA programming sections described below for configuration options.
[401] DLS/SA Options
1 - Double Call
ON: Calls for downloading or SA are answered if a successful double call routine is detected. Have
the downloading computer call the system and let the telephone line ring once or twice. After 1 or
2 rings, hang up. If called back within the duration of the double call timer (section [405]), the alarm
system answers on the first ring.
OFF : Incoming calls are not answered using the double call routine unless the user enables the DLS
window.
Note:
This feature controls the DLS window for PSTN connections only.
2 - User Enables/Disables DLS
ON : The [*][6][Master Code][05] command enables a 6-hour window where, on power-up,
downloading calls are answered if a successful double call routine is detected.
OFF: The user cannot enable a downloading window.
3 - DLS CallBack
ON : When a downloading call is answered, both the computer and the alarm system hang up. The
alarm system then calls the downloading computer back using the downloading telephone number
and begins the DLS session.
Note:
Disable this option if using more than one downloading computer.
OFF : After successful validation, the downloading computer gains immediate access to the alarm
system.
147
PowerSeries Neo HS2016/HS2016-4/HS3032/HS2064/HS2064 E/HS2128/HS2129 E Alarm Controller Reference
Manual