background image

 1

FX-DIS Local Controller Display Technical Bulletin 

Document Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3

Related Documentation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4

Local Controller Display on the Sensor Actuator (SA) Bus. . . . . . . . . . . . . . . . . . . . 5

Local Controller Display Keypad . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  7

Local Controller Display Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8

Local Controller Display Operation Overview. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8

Local Controller Display Menu Structure  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  9

Description of Local Controller Display  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  10

Local Controller Display Pages  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  11

Diagnostic Pages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  11

Controller Information Page . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  12

Idle/Favorites Page  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  12

Password Page . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  13

Change Password Page  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  14

Data Refresh Rate . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14

Detailed Procedures  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15

Entering a Password . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  15

Changing the Password  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  15

Displaying Configured Input and Output Points. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  17

Commanding Configured Input and Output Points . . . . . . . . . . . . . . . . . . . . . . . . . . . .  17

Displaying Configured Parameters and Setpoints . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  18

Commanding Configured Parameters and Setpoints  . . . . . . . . . . . . . . . . . . . . . . . . . .  19

Displaying Overridden Points. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  20

Viewing and Setting Display Information Preferences. . . . . . . . . . . . . . . . . . . . . . . . . .  21

Setting the Backlight Intensity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  23

FX-DIS Local Controller Display

Technical Bulletin

FX-DIS1710-0

Code No. LIT-12011666

Issued March 22, 2019

Supersedes  April 12, 2011

Summary of Contents for FX-DIS1710-0

Page 1: ...r Information Page 12 Idle Favorites Page 12 Password Page 13 Change Password Page 14 Data Refresh Rate 14 Detailed Procedures 15 Entering a Password 15 Changing the Password 15 Displaying Configured Input and Output Points 17 Commanding Configured Input and Output Points 17 Displaying Configured Parameters and Setpoints 18 Commanding Configured Parameters and Setpoints 19 Displaying Overridden Po...

Page 2: ...at Preference 24 Selecting the Display Precision Style 24 Setting the Display Contrast 25 Setting the Idle Timeout Value 25 Selecting the Time Format Preference 26 Displaying Controller Information 27 Logging Off the Display 27 Troubleshooting 27 Technical Specifications 28 FX DIS Local Controller Display 28 ...

Page 3: ...d Facility Explorer General Purpose Programmable Controllers FX PCGs that do not have an integral display For some FX PCGs the display is a built in component Use this document for both the stand alone and the built in display models This document does not describe how to commission the display with the Controller Configuration Tool CCT For details refer to Controller Tool Help LIT 12011147 See Re...

Page 4: ... 12011657 Installation Instructions and Specifications for the FX PCG16 and FX PCG26 FX PCG16 General Purpose Programmable Controller Installation Instructions Part No 24 10143 52 FX PCG26 General Purpose Programmable Controller Installation Instructions Part No 24 10143 160 Installation Instructions and Specifications for the PCV1617 and PCV1632 FX PCG16 General Purpose Programmable Controller In...

Page 5: ... controller and is connected to the SA Bus Figure 1 shows an example network of FX PC controllers with Local Controller Displays Figure 1 FX PC Controllers on the FC Bus FX_FIG DIS_Ntwrk FX PCG without Display FX PCG with Integral Display Typically a local display is mounted to the door of an enclosure that contains the controller FX DIS FC Bus FC Bus FX PCG with Local Display SA Bus FC Bus Note D...

Page 6: ...ng with the display Red Alarm LED Not used Removable Back Plate Used to hold the display onto the door of the enclosure Removable O Ring Fits inside gland around housing perimeter SA Bus Access Hole Cutout section on the removable back plate through which the SA Bus connector cable can pass for connection to the display Figure 2 Local Controller Display Dimensions mm in Removable O Ring Front View...

Page 7: ...on purposes and scroll the Idle page four items at a time Escape button cancels the current data value or selection This button also returns the display to the previous page Enter button performs the action of the highlighted field on the display This button also accesses the next menu level Pressing Escape Enter simultaneously logs off the user The display then returns to the Idle Favorites page ...

Page 8: ...ncluding contrast and backlight intensity select timeout settings select authorization including password definition These options are available in CCT through the Configure Display option found in the Tools menu while in Configuration mode For details refer to Controller Tool Help LIT 12011147 Local Controller Display Operation Overview The Local Controller Display uses a fixed set of display pag...

Page 9: ...tartup Diagnostic Pages Controller Information Page Idle Page Password Entry Page Enter Password Main Menu Page Input Output Page Parameter Setpoint Page Override Page Display Information Page Controller Information Page Change Password Page Logoff Focus Page Command Select Page Adjust Page State n Page Override Page Release Page Release All Page In Context Page Out of Context Page FIG MnuFlwAll P...

Page 10: ...d for the object exceeds the total allocated width For example if the value of an object is 12345 67 the displayed value may be shortened to 12345 depending on its initial length Pages on the Local Controller Display share a common method of row selection use a common method of entering data within an editable field show a scroll bar to indicate the scrolling feature is enabled support scrolling o...

Page 11: ...dle Favorites Page which displays important values and frequently referenced input and output points Figure 9 Diagnostic Pages When the controller is powered on the screen sequences through four pages as shown in Figure 7 If a problem is detected during startup the screen indicates the error condition If the controller is missing an application the Johnson Controls screen remains showing with the ...

Page 12: ...rmation from the Main Menu The information shown on the Controller Information page cannot be customized Idle Favorites Page The Idle Favorites page is the default view for the controller It shows a user defined ordered list of data points selected from within the application running in the controller Figure 9 Use CCT to specify which objects appear on this page Figure 8 Controller Information Pag...

Page 13: ...age for password character limits The Password page is presented when you press the Esc key Figure 10 From this page you individually select each character of your password An asterisk masks each selected character When you select Accept the password is authenticated and the Main Menu page appears If the password entered is not valid the controller displays Authorization Failed Message password ac...

Page 14: ...ssword is accepted the Main Menu page appears Data Refresh Rate Data shown on the Local Controller Display is periodically refreshed depending on controller activity and is not set by the user For monitored points Present Value and Reliability attributes update every 5 seconds For all other attributes values are updated within 120 seconds After 10 minutes with no keypad activity including being lo...

Page 15: ...entry use Backspace to erase one entry at a time or press Esc to clear the entire password and start over 3 When you have entered the entire password select Accept and press Enter The password is verified and the Main Menu appears Changing the Password To change the password 1 Go to the Main Menu by using the keypad See Local Controller Display Keypad 2 Scroll down and select the Change Password o...

Page 16: ...r new password select Accept and press Enter The Change Password confirmation page reappears Figure 17 9 Select Accept and press Enter The new password is confirmed and if accepted the Main Menu appears If the new and confirmed password entries do not match the message Passwords do not match appears Figure 14 New Password Page New Accept Cancel ABCDEFGHI FIG NwPwd Asterisks appear in place of type...

Page 17: ...r point select the point and press Enter The Focus page for the point appears Figure 19 is an example of a zone setpoint 5 Use the up down arrow keys to navigate through point details 6 Press Esc to return to the Main Menu Commanding Configured Input and Output Points To command configured input and output points 1 Go to the Main Menu 2 Select the Input Output option A list of all configured input...

Page 18: ...usting an analog setpoint 7 Press Enter to select Accept 8 Press Enter again to verify the selection and send the command 9 Press Esc to return to the Main Menu Displaying Configured Parameters and Setpoints To display configured parameters and setpoints 1 Go to the Main Menu 2 Select the Parameter Setpoints option A list of all configured parameters and setpoints appears 3 Use the up down arrow k...

Page 19: ...ain Menu 2 Select the Parameter Setpoints option A list of all configured parameters and setpoints appears 3 Use the up down arrow keys to select the parameter or setpoint for example analog or binary that you want to command 4 Press Enter The Focus page for the item appears with the Command option selected 5 Press Enter to display the commands available to this parameter or setpoint Figure 24 sho...

Page 20: ...ct Accept 8 Press Enter again to verify the selection and send the command 9 Press Esc to return to the Main Menu Displaying Overridden Points To display overridden points 1 Go to the Main Menu 2 Select the Overrides option A list of all points that are currently overriden appears Figure 26 If no points are overriden the user message Status No objects are overridden appears 3 Use the up down arrow...

Page 21: ...1 of 2 Parameter Description Selections Backlight Intensity1 Controls the brightness of the Local Controller Display Bright Medium Dim Off no backlighting Backlight Timeout Defines how long the display remains backlit when no user activity is present before going dim 1 minute 5 minutes 1 hour 8 hours Date Format Preference Sets how dates are presented on the display MM DD YY 01 15 07 MM DD YYYY 01...

Page 22: ...ample 22 MS TP Baud Rate Displays the configured Master Slave Token Passing MS TP baud rate Not configurable Example 38 400 Time Format Preference Sets how time of day appears on the display 12 MM 4 30 12 MM SS 4 30 30 12 MM AM PM 4 30 PM 12 MM SS AM PM 4 30 30 PM 24 MM 16 30 24 MM SS 16 30 30 1 Backlight intensity and display contrast both affect the readability of the display Best visibility is ...

Page 23: ... to return to the Main Menu Setting the Backlight Timeout To set the backlight timeout 1 Go to the Main Menu 2 Scroll down to select the Display Information option and press Enter 3 Scroll down to select the Backlight Timeout parameter and press Enter The Modify page appears 4 On the Modify page use the up down arrow keys to select a backlight timeout Figure 29 5 Press Enter to select Accept 6 Pre...

Page 24: ...cision Style To select the display precision style 1 Go to the Main Menu 2 Scroll down to select the Display Information option and press Enter 3 Scroll down to select the Disp Display Precision Style parameter and press Enter The Modify page appears 4 On the Modify page use the up down arrow keys to select the style to use as the separator in a number Figure 31 5 Press Enter to select Accept 6 Pr...

Page 25: ... return to the Main Menu Setting the Idle Timeout Value To set the auto logoff timeout value 1 Go to the Main Menu 2 Scroll down to select the Display Information option and press Enter 3 Scroll down to select the Idle Page Timeout parameter and press Enter The Modify page appears 4 On the Modify page use the up down arrow keys to select a new idle timeout value Figure 33 5 Press Enter to select A...

Page 26: ...eference parameter and press Enter The Modify page appears 4 On the Modify page use the up down arrow keys to find the format you want to use for displaying times Figure 34 5 Press Enter to select Accept 6 Press Enter again to save the setting and return to the Information page 7 Press Esc to return to the Main Menu Figure 34 Modify Time Format Preference Page Modify Accept Cancel Time Format Pref...

Page 27: ...indicated Current status of the controller Operational CTRL List of the controller s point capacities 6 UI 2 BI 3 BO 2 AO 4 CO Model Name Model name of the controller FX PCG2611 0 Object Name2 2 This attribute is defined when the application is configured using CCT Object name of the controller FC 22 System Name2 Name of the system application in the controller FCapp Local Site Director Not applic...

Page 28: ...ck at Service Port Covered by Removable Cap Plug SA Bus Connection on Back of Unit Processor Renesas H8S 2398 32 bit Microprocessor Memory 256 KB Flash Memory 8 KB Random Access Memory RAM Operating System RTOS H8S Network and Serial Interfaces Communication to FX PC Controller Over SA Bus Graphic Display Resolution 240 pixels x 64 pixels with White LED Backlighting Adjustable Dimensions Height x ...

Reviews: