Installation Manual for Snow Protection Hood (for Outdoor Unit)

This snow protection hood prevents snow from entering the outdoor unit and prevents strong winds  from 
blowing against the heat exchanger.  Be sure to read this manual carefully for correct performance before 
installation work.

IMPORTANT NOTICE:

•  Johnson Controls pursues a policy of continuous improvement in design and performance of products. 

We reserve the right to vary speci

fi

 cations without notice.

•  No part of this manual may be reproduced without Johnson Controls’ written permission.
•  Keep this manual for future reference.
•  Johnson Controls cannot anticipate every possible circumstance that might involve a potential hazard.
•  This kit is designed for a combination of Johnson Control air conditioners. Do not use this kit by itself or in 

combination with other companies’ air conditioners.

•  To hold the snow protection hood properly to the outdoor unit against the strong wind or earthquake, stay 

or safety wire rope shall be used for reinforced installation.  Use the 

fi

 eld-supplied safety wire rope to 

prevent outdoor unit from overturning.

•  Perform a test run after installation to check for abnormalities.
•  Signal words are used to identify levels of hazard seriousness. De

fi

 nitions for identifying hazard levels are 

provided below with their respective signal words.

 

  :  Indicates a hazardous situation that, if not avoided,

 

  could result in death or serious injury.

 

  :  Indicates a hazardous situation that, if not avoided,

 

  could result in minor or moderate injury.

1. Applicable Unit

NOTE

:

Applicable outdoor unit may be different depending on the product series.  Be sure to con

fi

 rm with the 

product catalogue before installation.

Name

Hood for Right Side Air Inlet

Model

ASG-TP20RS2

Required Qty.

x 1

Applicable Outdoor Unit

Top Flow Type 

72,000, 96,000, and 120,000 Btu/h

2. Installation Work

(1)  After the snow protection hood is installed, electromagnetic noise at the air outlet side may slightly 

increase.  Therefore, it is necessary to carefully consider the air discharge direction when installed.

(2)  Be sure to tighten the snow protection hood securely to the top panel and side panel of the outdoor 

unit with the supplied screws (accessories).  Not doing so may cause vibration or abnormal noise.

(3)  There must be no obstacles in the air discharge direction of the snow protection hood.  If there are, it 

may cause a short circuit or an insuf

fi

 cient air

fl

 ow rate.

(4)  Do not install other outdoor units in the direction of the air outlet.  If the air blown out of the snow 

protection hood is sucked into the other outdoor unit, it may cause a malfunction of the unit.

(5)  The wind loads which the outdoor unit receives changes by attaching the snow protection hood.  The 

required installation strength will also change in strong wind.  Therefore, recheck the strength of the 
anchor bolts of the outdoor unit.

(6)  If the snow protection hood is installed, cooling/heating performance may be slightly lowered 

depending on the usage conditions.