www.johnsonandstarley.co.uk
6
6.5
LOSS OF SYSTEM WATER PRESSURE
The pressure gauge indicates the central heating system pressure. If the pressure is seen to fall below the
original installation pressure of 1-2 bar over a period of time then a water leak may be indicated. In this event
conduct the re-pressurising procedure as shown. If unable to do so or if the pressure continues to drop a
Gas Safe Registered Engineer or in IE a Registered Gas Installer (RGII) should be consulted.
The boiler will not operate if the pressure has reduced to less than 0.3 Bar under this condition.
1. Ensure filling loop isolation valves are closed.
2. Remove the two caps
3. Attach on the filling loop.
4. Turn the filling loop isolation valves to the open position. The system will now fill.
5. Wait for pressure gauge dial to reach 1 to 1.5 bar.
6. Close the filling loop isolation valves.
7. Disconnect the filling loop at left hand side and angle upwards.
8. Attach the two caps as shown on point 2.
6.6
CONDENSATE DRAIN
The condensate drain must not be modified or blocked.
Blockage of the condensate drain, caused by debris or freezing, can cause automatic shutdown of the
boiler.
If freezing is suspected and the pipe run is accessible an attempt may be made to free the obstruction by
pouring hot water over the exposed pipe and clearing any blockage from the end of the pipe. If this fails to
remedy the problem the assistance of a Gas Safe Registered Engineer or in IE a Registered Gas Installer
(RGII) should be sought.
7.
RESET BOILER
Press the reset button “K4” twice.
8.
SERVICING & MAINTENANCE
It is recommended that a full maintenance check be carried out annually on the appliance. It is also
recommended to take out a further service agreement on the expiry of the guarantee period.
You can obtain further information on this from your gas supplier.
The appliance should be checked /serviced by a GAS SAFE registered
installer.
If you require service on your appliance please contact your local installer or
gas supplier.
On completion of the service the installer should fill in the service section at the rear of the BENCHMARK
checklist. All installers registered with GAS SAFE carry an identification card. This card will have an ID
number which should be recorded.
If you have any queries regarding your installer you can contact GAS SAFE by telephone on 0800 408 5500.
The appliance should be serviced at least once a year by a Gas Safe Registered Engineer or in IE a
Registered Gas Installer (RGII).
9.
CLEANING
For normal cleaning simply dust with a dry cloth.
To remove stubborn marks and stains, wipe with a damp cloth and finish off with a dry cloth.
DO NOT use abrasive cleaning materials.
10. ESCAPE OF GAS
Should a gas leak or fault be suspected contact the National Gas Emergency Service without delay.
Telephone 0800 111 999
Do NOT search for gas leaks with a naked flame.