background image

Read this manual before operating the nebulizer. 

Save this manual for future reference.
Info: The most current version of this manual can be 

found online at www.grahamfield.com.

 

Federal Law (USA) restricts this device to sale by or 

on the order of a physician. This device should not 

be used unless the operator has been instructed by 

a qualified healthcare professional.

Neb-u-Tyke

®

 Speedster

Nebulizer Compressor

Item JB0112-067

User Manual

JB0112-067-INS-LAB-RevC14

Summary of Contents for JB0112-067

Page 1: ...l can be found online at www grahamfield com Federal Law USA restricts this device to sale by or on the order of a physician This device should not be used unless the operator has been instructed by a qualified healthcare professional Neb u Tyke Speedster Nebulizer Compressor Item JB0112 067 User Manual JB0112 067 INS LAB RevC14 ...

Page 2: ...g the most current version of this manual can be found online at www grahamfield com Graham Field John Bunn and Neb u Tyke are registered trademarks of GF Health Products Inc 2007 GF Health Products Inc CONTENTS INTRODUCTION 3 INTENDED USE 3 SYMBOLS KEY 3 IMPORTANT SAFETY PRECAUTIONS 4 PRODUCT DESCRIPTION 7 FEATURES AND COMPONENTS 7 SETUP 8 OPERATION 10 SAFETY OVERLOAD 11 MAINTENANCE 12 CLEANING T...

Page 3: ... pulmonary disease and other respiratory disorders in accordance with a physician s prescription Do not use this product for any other purpose than the preceding This device can be used with adult or pediatric patients under physician s prescription Symbols Key O Off I On Alternating current IPX0 Enclosed equipment without protection against ingress of water Attention read the instructions II Clas...

Page 4: ...ld result in minor or moderate personal injury s NOTICE Indicates a potential hazard or unsafe practice that if not avoided could result in product or property damage Info Provides application recommendations or other useful information to ensure that you get the most from your product READ ALL INSTRUCTIONS BEFORE USING DANGER To reduce the risk of electrocution 1 Always unplug this product immedi...

Page 5: ...te this product if a it has a damaged cord or plug b it is not working properly c it has been dropped or damaged or d it has been dropped into water Return the product to your Graham Field authorized distributor for examination and repair 6 Keep the cord away from heated surfaces 7 Never block the air openings of this product or place it on a soft surface such as a bed or couch where the air openi...

Page 6: ...ulizer 15 This device is oil free Do not lubricate 16 Do not remove the jet nebulizer while the device is operating 17 Do not leave medication inside the jet nebulizer when it is not in use 18 Use the nebulizer intermittently the maximum operating period is 30 minutes The nebulizer must stand unused for 30 minutes between uses 19 The mouthpiece and optional mask are for use by one person only in o...

Page 7: ...artment lid air outlet connector for tubing T adapter reservoir tube tubing Neb u Tyke Speedster Nebulizer Compressor Info Neb u Tyke Speedster replacement parts are available at www grahamfield com or from your Graham Field authorized distributor Item No Description JB77200 Neb u Tyke Speedster Nebulizer Compressor complete with Garage Bag JB0112 067 Neb u Tyke Speedster Nebulizer Compressor with...

Page 8: ...or in an area that is clean and dust free Be sure you can easily reach the controls when seated 3 Open the nebulizer medication cup Twist the cap counter clockwise until it stops then lift cap off 4 Pour the prescribed medication into the nebulizer medication cup Do not fill with more than 5 ml per treatment 5 Install cap on cup Turn clockwise to tighten 6 If using the mouthpiece for treatment pro...

Page 9: ...the reservoir tube install it now on the small end of the T adapter 8 Install T adapter onto top of nebulizer medication cup cap 9 Connect the tubing to the adapter on the bottom of the nebulizer medication cup 10 Connect the tubing s other end to the compressor air outlet connector WARNING Before use check that all parts are securely connected Use of an improperly assembled nebulizer could dimini...

Page 10: ...h and close mouth or install the optional mask on face 5 As aerosol starts flowing inhale deeply and slowly through mouthpiece or optional mask WARNING Never use a nebulizer with a clogged nozzle If the nozzle is clogged the aerosol mist will be reduced altered or stopped which will diminish or eliminate the effectiveness of the treatment If clogging occurs replace the nebulizer Info If you need t...

Page 11: ...l automatically shut off the motor Should this occur move the ON OFF switch to the OFF position and allow the motor to cool down for approximately 30 minutes before turning it on again 2 If the overload protector shuts off the motor frequently you may have an unstable voltage situation 3 If the device shuts down and cannot restart it may need to be replaced Call your Graham Field authorized distri...

Page 12: ...red type cleaners or soap Cleaning the Nebulizer Cup All parts of the disposable nebulizer except tubing should be thoroughly cleaned after each use If your physician specifies a specific cleaning procedure follow that procedure WARNING To prevent possible risk of infection from contaminated medication clean the nebulizer after each treatment 1 After each use disassemble the nebulizer cup T adapte...

Page 13: ...e the dirty filter with a small pointed object Discard the filter 3 Replace with a clean filter Additional filters are available from your Graham Field authorized distributor 4 Replace the filter cap s NOTICE Do not use cotton or other materials as a filter s NOTICE Do not wash or clean the filter s NOTICE Do not reuse the filter Do not operate compressor without a filter Compressor damage can res...

Page 14: ...n device has been run continuously for more than 30 minutes just before using auto shut down may have been activated by the built in thermal protector ensure that device is OFF for at least 30 minutes before next usage Nebulization is weak Check for proper electrical voltage Check tubing for blockage or air leakage at connection to Neb u Tyke compressor or nebulizer cup replace as needed Check tha...

Page 15: ...ons Capacity 5 ml Filter Sponge Dimensions LxWxH 10 2 6 9 3 7 25 9 cm x 17 5 cm x 9 4 cm Weight 3 8 lb 1 73 kg Electrical requirement 115VAC 60Hz Current 1 2A rate Fuse 2 5A 250V Power cord Black 7 ft 84 213 4 cm Plug 2 prong type Sound level 54dba Environment Temperature Operation 41 F to 104 F 5 C to 40 C Storage 14 F to 158 F 10 C to 70 C Humidity Operation 30 to 95 RH Storage 10 to 95 RH ...

Page 16: ... OBTAINING WARRANTY SERVICE A GF Customer Service Representative must authorize warranty service Please contact the GF Customer Service department by calling 678 291 3207 sending a fax request to 770 368 2386 or by e mailing a request to cs grahamfield com Specific directions will be provided by the Customer Service Representative Failure to abide by the specific directions will result in denial o...

Page 17: ... DOWNTIME COVER OR EMPLOYEE OR INDEPENDENT CONTRACTOR WAGES PAYMENTS AND BENEFITS The warranties contained herein contain all the representations and warranties with respect to the subject matter of this document and supersede all prior negotiations agreements and understandings with respect thereto The recipient of this document hereby acknowledges and represents that it has not relied on any rep...

Page 18: ...Manufactured for GF Health Products Inc 2935 Northeast Parkway Atlanta Georgia 30360 USA Telephone 770 368 4700 Fax 770 368 2386 www grahamfield com Made in China ...

Page 19: ...encontrado en www grahamfield com La Ley Federal USA restringe este aparato para ventas por la orden de su médico Este aparato no debe ser utilizado si el operador no ha sido adiestrado por profesional de cuido de salud cualificado Neb u Tyke Speedster Compresor de Nebulizador Modelo JB0112 067 Manual de Usuario JB0112 067 INS LAB RevC14 ...

Page 20: ... DE AIRE 13 ALMACENAJE 13 DETECTANDO PROBLEMAS 14 ESPECIFICACIONES 15 GARANTÍA LIMITADA 16 Este producto ha sido examinado y aprobado con los siguientes estándares UL1431 EN 60601 1 GF Health Products Inc no es responsable de errores tipográficos Para obtener la información más actualizada y vigente relativa a los envases garantías productos y especificaciones incluyendo la versión más actualizada...

Page 21: ...cción de la zona superior respiratorio enfermedad pulmonar obstructiva crónica y otros desordenes que va de acuerdo con la receta de su médico No debe usar este producto por cualquier otro propósito que lo descrito arriba Este aparato puede ser usado con pacientes adultos y pediátricos con la receta de su médico Símbolos O Apagado I Encendido Corriente alternando IPX0 El equipo no tiene protección...

Page 22: ...ituación de peligro o una practica insegura que si no es evitada podría dar lugar a daños de menor importancia al producto o daños materiales Info Proporciona recomendaciones para la aplicación y otra información útil para asegurar que obtengas lo más que pueda del producto LEE TODAS LAS INSTRUCCIONES ANTES DE UTILIZAR PELIGRO para reducir el riesgo de electrocución 1 Siempre debe desconectar este...

Page 23: ...omendados por GF Health Products Inc 5 Nunca utilice este producto si a el enchufe o el cable está dañado b no funciona adecuadamente c ha sufrido caída o daño o d ha sido mojado o sumergido en agua Devuelve este producto al centro de servicio para examen y o arreglos 6 Mantenga el cable lejos de superficies calientes 7 Nunca obstruya entradas de aire del producto o utilice en una superficie suave...

Page 24: ... el aparato antes de llenar el nebulizador 15 Este aparato no utiliza aceite No lubrique 16 No debe remover el nebulizador de chorro cuando el apa rato está operando 17 No debe dejar medicamento en el nebulizador cuando no esté en uso 18 Use el nebulizador por periodos el periodo de operación máximo es 30 minutos El nebulizador no debe ser usado por 30 minutos entre usos 19 La boquilla y la máscar...

Page 25: ...ruptor de ON OFF a la derecha del filtro conector del enchufe de aire boquilla taza del nebulizador adaptador T manga de reserva manga Info Neb u Tyke Speedster piezas reemplazadas están disponibles en www grahamfield com o de su distribuidor autorizado de Graham Field Modelo Descripción JB77200 Neb u Tyke Speedster Compresor de Nebulizador completo con Bolso del Garaje JB0112 067 Neb u Tyke Speed...

Page 26: ...za de nebulizador para daño reemplace si es necesario 2 Posicione el aparato en una superficie horizontal para que los controles estén con fácil acceso No debe usar este aparato en el piso 3 Remueva la tapa de la taza del nebulizador 4 Inserte medicamento prescrito por su médico 5 Reúne taza y tapa 6 Si usa la boquilla para el tratamiento proceda al paso 7 Si usa la máscara opcional instale la par...

Page 27: ...eserva posicione en la parte inferior del adaptador T 8 Instale el adaptador T sobre la tapa de la taza del nebulizador 9 Conecte la manga al adaptador a la parte inferior de la taza nebulizador 10 Conecte la otra parte de la manga al conector de mango del compresor ADVERTENCIA Antes de uso verifique que todas las piezas están conectados correctamente Uso de un nebulizador armado incorrectamente p...

Page 28: ... 5 Cuando el aerosol empiece a fluir necesita inhalar profundamente y despacio a través de la boquilla o la máscara ADVERTENCIA Nunca debe usar el nebulizador con un inyector tapado Si el inyector está tapado la nube de aerosol será reducido cambiado o parado que puede diminuir o eliminar la efectividad del tratamiento Si se tapa reemplace el nebulizador Info Si el tratamiento necesita ser interru...

Page 29: ... comienza a sobrecalentarse se apagará automáticamente Si esto ocurre posicione el interruptor a la posición OFF y permita que el motor se enfrié por 30 minutos antes de recomenzar el compresor 2 Si el protector apaga el motor frecuentemente podría tener una situación de voltaje inestable 3 Si el aparato se apaga y no se enciende puede ser necesario reemplazarlo Llame a su proveedor inmediatamente...

Page 30: ...ieza de la Taza del Nebulizador Todas las piezas del nebulizador desechable excepto la manga deben ser limpiados después de cada uso Si su médico le da un procedimiento especifica de limpieza siga ese procedimiento ADVERTENCIA Para prevenir riesgo de infección causado por medicamento contaminado la limpieza del nebulizador se recomienda después de cada tratamiento 1 Después de cado uso desensamble...

Page 31: ... aire localizado al lado del interruptor ON OFF 2 Remueva el filtro sucio con un objeto punzante 3 Reemplace el filtro nuevo 4 Reemplace la tapa del filtro s AVISO No utilice algodón o cualquier material como filtro s AVISO No lave o limpie el filtro s AVISO No reutilice el filtro No opere sin filtro El compresor puede ser dañado por este uso ADVERTENCIA El kit del nebulizador desechable es para u...

Page 32: ...propiada Cuando el aparato ha estado corriendo continuamente por más de 30 minutos el protector termal interno puede ser activado para que el aparato se enfríe por 30 minutos antes del próximo uso Nebulización es débil Verifique que tiene el voltaje eléctrico apropiado Verifique la manga para bloqueos o escapes de aire en la conexión al compresor o la taza de nebulizador reemplace si es necesario ...

Page 33: ...cidad 5 ml Filtro Esponja Dimensión LxWxH 10 2 6 9 3 7 25 9 cm x 17 5 cm x 9 4 cm Peso 3 8 lb 1 73 kg Requísito eléctrico 115VAC 60Hz Corriente 1 2A tasa Capacidad de fusible 2 5A 250V Cordón eléctrico Negro 7 ft 84 213 4 cm Enchufe De tipo de 2 Aspa Nivel de sonido 54dba Ambiente Temperatura Operación 41 F a 104 F 5 C to 40 C Almacenaje 14 F to 158 F 10 C to 70 C Humedad Operación 30 a 95 RH Alma...

Page 34: ... reportados al Distribuidor de quien el Cliente compro el producto y quienes ellos en turno notifica al equipo de Servicio de Cliente de GF dentro el período de garantía aplicable en cuanto será examinado por GF o un representante autorizado para probar el producto sobre garantía Falta de seguir las instrucciones específicas resultara en rechazo de la reclamación de garantía Si no hay Distribuidor...

Page 35: ... Y NO PARA REPRESENTAR QUE EL PRODUCTO SE CONFORME CON ESE MODELO Y MUESTRA EN TODOS RESPETOS TODA RESPONSABILIDAD DE GF POR CUAL QUIER PRODUCTO Y SERVICIO PROVIDO ES LIMITADA AL COSTO DEL PRODUCTO EN LA RECLAMACION EN NO EVENTO EN CONTRACTO INDEMNIZACION GARANTIA NEGLIGENCIA RESPONSABILIDAD ESTRICTA O OTRO QUE GF SERA RESPONSABLE POR CUAL QUIER DANO DIRECTO ESPECIAL INDIRECTO INCIDENTAL EJEMPLAR ...

Page 36: ...Fabricado para GF Health Products Inc 2935 Northeast Parkway Atlanta Georgia 30360 USA Telephone 770 368 4700 Fax 770 368 2386 www grahamfield com Fabricado en China ...

Reviews: