background image

User-Service Manual

Joerns® Support Surface

DermaFloat® LR Model

To avoid injury, read user’s manual before using.

Joerns Healthcare 1_Art Direction_Joerns Beds_700 Series_UltraCare 8page

5/2007_Page 1 of 8

Summary of Contents for DermaFloat LR

Page 1: ...User Service Manual Joerns Support Surface DermaFloat LR Model To avoid injury read user s manual before using...

Page 2: ...presence of smoking materials or open flame Air flowing through the air mattress will support combustion 2 Danger To reduce the risk of shock adhere to the following instructions Failure to do so cou...

Page 3: ...manufacturer of long term care beds and a frontrunner in addressing this critical issue Joerns Healthcare can offer you the expertise assistance and products to bring your facility into compliance Jo...

Page 4: ...ort Power Failure Low Pressure Alarm Optional Accessories Troubleshooting 9 10 Therapy Surface Not Inflating Unable to Change Therapy Mode or Adjust Comfort Control Troubleshooting Modes of Operation...

Page 5: ...with the attending physician 5 Introduction The DermaFloat LR provided by Joerns Healthcare is a unique continuous bilateral rotation mattress replacement system This system is designed to assist in t...

Page 6: ...of cleaning re assembly and cost effective service Lower two inch therapy support cell provides additional therapeutic support and remains inflated for up to 12 hours in the event of a power failure...

Page 7: ...cal system with more reliable equipment If repair or replacement of the cord or plug is necessary please contact Joerns Healthcare for assistance 7 Setup Warning For important precautions please see p...

Page 8: ...prior to Autofirm either Turn or Static in approximately 15 minutes Pause Use this feature to immediately stop all rotation and hold the current mattress position The mattress will hold this position...

Page 9: ...e an audible alarm and will flash L and P on the display Once the low pressure condition has been corrected the alarm will cease and the control unit will return to normal operation Optional Accessori...

Page 10: ...nent of urine and or stool and residents with heavily draining wounds Add top sheet blanket and or bedspread as needed for resident comfort Keep the amount of padding between the resident and bed to a...

Page 11: ...age with possible body fluids it is recommend that the mattress system be cleaned with a mild detergent and warm water If disinfection is desired a combination cleanser disinfectant may be used as exp...

Page 12: ...ithout Joerns s authorization will invalidate any warranties on this product Storage and Care Note Clean the DermaFloat LR as described in the previous section prior to storage Control Unit The power...

Page 13: ...sive usage Improper maintenance handling and or cleaning Failure to use in the manner indicated in the DermaFloat LR user manual Any modification repair or alteration done to the DermaFloat LR that wa...

Reviews: