10
9
CLEANING AND CARE
•
Wipe off surfaces with soft, moist cloth. Do not clean the heater with cleaning
products that are combustible or corrosive.
•
Remove debris and insects from the burner periodically to keep it clean and safe
for use.
•
Cover the burner unit with the optional protective cover when the heater is not in
use.
PARTS AND SPECIFICATION
2270 mm
900 mm
650 mm
730 mm
Reflector
Glass Tube
Top Plate Assy
Protective Guard
Upper Support
Front Panel
Side Panel
Lower Support
Bottom plate
CONSTRUCTION AND CHARACTERISTICS
• Transportable terrace/garden heater with cylinder housing.
• Constructed with aluminium, powder coated and stainless steel
• Heat is emitted upwards through the glass tube and distributed via the top
reflector.
SPECIFICATIONS
• This heater is best used with propane gas
• Max. wattage: 13kw
• Min. wattage: 5kw
Gas Consumption
APPLIANCE CATEGORY:
3+(28-30/37)
3B/P(30)
3B/P(50)
3B/P(37)
TYPES OF GAS:
Butane
Propane
Butane, propane
or their mixtures
Butane, propane
or their mixtures
Butane, propane
or their mixtures
GAS PRESSURE:
28-30mbar
37 mbar
30 mbar
50mbar
37mbar
OUTLET PRESSURE
OF REGULATOR:
30mbar
37 mbar
30 mbar
50mbar
37mbar
Use the correct regulator according to outlet pressure of regulator as showed in the table above.
Injector Information
APPLIANCE CATEGORY:
3+(28-30/37)
3B/P(30)
3B/P(50)
I
I
I
I
I
I
I
I
3B/P(37)
TYPES OF GAS:
Butane
Propane
Butane, propane
or their mixtures
Butane, propane
or their mixtures
Butane, propane
or their mixtures
GAS PRESSURE:
28-30mbar
37 mbar
30 mbar
50mbar
37mbar
TOTAL HEAT
INPUT (Hs): (Qn)
13kW (945g/h)
INJECTOR SIZE:
1.88 mm for main burner
0.18 mm for pilot burner
1.55 mm for main burner
0.18 mm for pilot burner
1.65 mm for main burner
0.18 mm for pilot burner
The marking
,
for example
,
1.88 on the injector
,
indicates that the size of injector is 1.88mm
•
•
The hose and regulator assembly must conform to adequate standards.
Regulator outlet pressure should meet the corresponding appliance category in
the Specification section above. The appliance requires approved hose with a
minimum length of 0.5
m.
Summary of Contents for JMC-OSPH-SS
Page 1: ......