17
LEAK TEST
Please ensure you follow the procedure on page 7 before operating the heater.
TROUBLESHOOTING
Problem
Probable Cause
Suggested Solution
Pilot will not light
Gas regulator may be
OFF
Turn the regulator ON
Gas cylinder empty
Replace with full cylinder
Opening blocked
Clean or replace opening
Air in supply system
Purge air from lines
Loose connections
Check all fittings
Pilot will not stay
on
Debris around pilot
Clean dirty area
Loose connections
Tighten connections
Thermocouple faulty
Replace thermocouple
Anti tilt switch loose/faulty Reconnect/replace anti tilt switch
Gas leak in line
Check connections
Lack of fuel pressure
Tank near empty. Refill LPG tank.
Burner will not
light
Pressure is low
Cylinder is almost empty. Replace
with full cylinder
Opening blocked
Remove and clean
Control not ON
Turn valve to ON
Thermocouple faulty
Replace thermocouple
Pilot light assembly bent
Place pilot properly
Not in correct location
Position properly and retry
If you have any other issues, please contact your supplier or distributor. Please do not
attempt to modify the heater in any way or form.