CAMERA
In presenting of halos on the surface, use specific products for cleaning of
cameras
(10.) commercially available to not damage the lenses.
SENSOR
Use a damp cloth with non-abrasive/granular neutral detergent, avoiding
scratches to the sensor surface
(5.2)
, halos and sediments.
NOZZLE
Remove with a damp cloth the solid gel residues that could settle around the
nozzle
(5.1)
.
PUMP
At least 0,5 litres of water shall be aspirated to lose under automatic loading
conditions. It is recommended to empty the hydraulic circuit in the vicinity of
the cleaning termination, removing the suction, to drain the hydraulic circuit
completely. This operation must be repeated every 6 months, or after/before a
scheduled period of unusing of about 2 weeks (depending on the liquid in use
and environmental conditions).
COLLECTION TRAY/DRAINAGE GRID
Periodically remove the drainage grid
(5.3)
to remove with a damp cloth the
remaining sanitizing gel from the latter and from the collection tray
(5.4)
below.
TANK
It is mandatory to regularly check the integrity of the tank
(15.)
to ensure safe
and efficient utilization.