SECTION 7 - BASIC ELECTRICAL INFORMATION & ELECTRICAL SCHEMATICS
3121714
7-7
BRAD HARRISON / PHOENIX CONTACT M12
The connector uses gold contact material to resist corrosion
and an o-ring seal for moisture integrity. If dielectric grease is
mistakenly applied to this connector system, the low-force
contacts cannot displace the grease to achieve electrical con-
tact. Once contaminated, there is no practical way to remove
the dielectric grease (replacement of female contacts
required). The JLG Load Sensing System and 1250AJP Rotary
Angle Sensors are examples of components with the M12 con-
nector system.
AMP JUNIOR TIMER
This type of connector uses back-seals for moisture integrity.
However, the low-force contacts cannot displace dielectric
grease and create electrical contact. It is possible to use sol-
vents (i.e. contact cleaner or mineral spirits) for the removal of
improperly applied dielectric grease. The EMR2 engine control
module from Deutz employs this connector system (for exam-
ple).
Summary of Contents for E450A
Page 2: ......
Page 22: ...SECTION 1 SPECIFICATIONS 1 4 3121714 Figure 1 2 Maintenance Lubrication Diagram...
Page 51: ...SECTION 3 CHASSIS TURNTABLE 3121714 3 11 1001116232 A Figure 3 9 Drive Limit Switch...
Page 64: ...SECTION 3 CHASSIS TURNTABLE 3 24 3121714 1 0 Figure 3 18 Drive Hub Sheet 1 of 2...
Page 76: ...SECTION 3 CHASSIS TURNTABLE 3 36 3121714 Figure 3 27 Swing Components...
Page 96: ...SECTION 3 CHASSIS TURNTABLE 3 56 3121714 GENERATOR Figure 3 30 On Board Generator...
Page 116: ...SECTION 3 CHASSIS TURNTABLE 3 76 3121714 NOTES...
Page 343: ...SECTION 6 JLG CONTROL SYSTEM 3121714 6 27 CONNECTOR Figure 6 10 Power Module LH 1001192212 D...
Page 344: ...SECTION 6 JLG CONTROL SYSTEM 6 28 3121714 Figure 6 11 Power Module RH CONNECTOR 1001178339 E...
Page 479: ......