SECTION 6 - JLG CONTROL SYSTEM
3121714
6-39
9/9
Flash code 9/9 indicates problems with the controller.
POWER MODULE FAILURE: CONTACTOR DRIVE CODE 1
A contactor remained energized when turned off.
POWER MODULE FAILURE: HWFS CODE 2
The hardware failsafe tests did not complete because traction point A is not safe, or the hardware failsafe is perma-
nently tripped.
POWER MODULE FAILURE: HWFS CODE 3
The hardware failsafe tests did not complete because a contactor was energized when all should be turned off
POWER MODULE FAILURE: HWFS CODE 4
The hardware failsafe tests did not complete because the hardware failsafe tripped immediately when the traction
MOSFETs were turned on.
POWER MODULE FAILURE: HWFS CODE 10
The hardware failsafe tests failed because the hardware failsafe did not trip within the allowed test time.
POWER MODULE FAILURE: HWFS CODE 11
The hardware failsafe tests failed because the hardware failsafe tripped too slowly.
POWER MODULE FAILURE: HWFS CODE 12
The hardware failsafe tests failed because the hardware failsafe tripped too quickly.
POWER MODULE FAILURE: HWFS CODE 13
The hardware failsafe tests failed because the hardware failsafe remained tripped when the traction MOSFETs were
turned off.
POWER MODULE FAILURE: HWFS CODE 14
The hardware failsafe tests failed because the line contactor could still be energized when the hardware failsafe was
tripped
POWER MODULE FAILURE: HWFS CODE 15
The hardware failsafe tests failed because the contactor drive failsafe did not trip within the allowed test time.
POWER MODULE FAILURE: HWFS CODE 16
The hardware failsafe tests failed because the contactor drive failsafe tripped too slowly.
POWER MODULE FAILURE: HWFS CODE 17
The hardware failsafe tests failed because the contactor drive failsafe tripped too quickly.
POWER MODULE FAILURE: HWFS TEST STALLED
The hardware failsafe tests did not complete, but no reason can be determined.
POWER MODULE FAILURE: BAD TEMPERATURE SENSOR
The temperature sensor measurement is invalid, this is probably due to a disconnected wire within the power mod-
ule. The possibility of other disconnected wires (which could cause dangerous system function) means that the
controller is shut down.
POWER MODULE FAILURE: S/C LINE CONTACTOR DRIVER The line contactor energized when the footswitch was
closed, before it was turned on, this is probably due to a failed driver within the power module, although it could be
due to bad power module wirings
Table 6-8. Help Descriptions and Fault Flash Codes
Summary of Contents for E450A
Page 2: ......
Page 22: ...SECTION 1 SPECIFICATIONS 1 4 3121714 Figure 1 2 Maintenance Lubrication Diagram...
Page 51: ...SECTION 3 CHASSIS TURNTABLE 3121714 3 11 1001116232 A Figure 3 9 Drive Limit Switch...
Page 64: ...SECTION 3 CHASSIS TURNTABLE 3 24 3121714 1 0 Figure 3 18 Drive Hub Sheet 1 of 2...
Page 76: ...SECTION 3 CHASSIS TURNTABLE 3 36 3121714 Figure 3 27 Swing Components...
Page 96: ...SECTION 3 CHASSIS TURNTABLE 3 56 3121714 GENERATOR Figure 3 30 On Board Generator...
Page 116: ...SECTION 3 CHASSIS TURNTABLE 3 76 3121714 NOTES...
Page 343: ...SECTION 6 JLG CONTROL SYSTEM 3121714 6 27 CONNECTOR Figure 6 10 Power Module LH 1001192212 D...
Page 344: ...SECTION 6 JLG CONTROL SYSTEM 6 28 3121714 Figure 6 11 Power Module RH CONNECTOR 1001178339 E...
Page 479: ......