SECTION 4 - BOOM & PLATFORM
3121714
4-5
4.3
MAIN BOOM POWERTRACK (E/M450AJ)
Removal
1.
Disconnect wiring harness connectors located in main
upright.
HYDRAULIC LINES AND PORTS SHOULD BE CAPPED IMMEDIATELY AFTER DIS-
CONNECTING LINES TO AVOID ENTRY OF CONTAMINANTS INTO SYSTEM.
2.
Tag and disconnect hydraulic lines to the connectors at
boom assembly. Use a suitable container to retain any
residual hydraulic fluid. Cap hydraulic lines and ports.
3.
Remove hydraulic lines and electrical cables from Pow-
ertrack.
NOTE:
The Main Boom weighs approximately 590lbs. (268kg).
4.
Using suitable lifting equipment, adequately support
Powertrack weight along entire length.
5.
Remove bolts #1 securing the push tube on the fly
boom section.
6.
Remove bolts #2 that attaches rail to the push tube on
the main boom section.
7.
With powertrack supported and using all applicable
safety precautions, remove bolts #3 securing rail to the
base boom. Remove powertrack from the boom section.
Installation
NOTE:
The Main Boom weighs approximately 590lbs. (268kg).
1.
Using suitable lifting equipment, adequately support
Powertrack weight along entire length.
2.
With powertrack supported and using all applicable
safety precautions, Install bolts #3 securing rail to the
base boom.
3.
Install bolts #2 that attaches rail to the push tube on the
main boom section.
4.
Install bolts #1 securing the push tube on the fly boom
section.
5.
Remove tag and reconnect all hydraulic lines.
6.
Reconnect all electrical harness.
Summary of Contents for E450A
Page 2: ......
Page 22: ...SECTION 1 SPECIFICATIONS 1 4 3121714 Figure 1 2 Maintenance Lubrication Diagram...
Page 51: ...SECTION 3 CHASSIS TURNTABLE 3121714 3 11 1001116232 A Figure 3 9 Drive Limit Switch...
Page 64: ...SECTION 3 CHASSIS TURNTABLE 3 24 3121714 1 0 Figure 3 18 Drive Hub Sheet 1 of 2...
Page 76: ...SECTION 3 CHASSIS TURNTABLE 3 36 3121714 Figure 3 27 Swing Components...
Page 96: ...SECTION 3 CHASSIS TURNTABLE 3 56 3121714 GENERATOR Figure 3 30 On Board Generator...
Page 116: ...SECTION 3 CHASSIS TURNTABLE 3 76 3121714 NOTES...
Page 343: ...SECTION 6 JLG CONTROL SYSTEM 3121714 6 27 CONNECTOR Figure 6 10 Power Module LH 1001192212 D...
Page 344: ...SECTION 6 JLG CONTROL SYSTEM 6 28 3121714 Figure 6 11 Power Module RH CONNECTOR 1001178339 E...
Page 479: ......