SECTION 7 - BASIC ELECTRICAL INFORMATION & ELECTRICAL SCHEMATICS
7-2
31215031
Resistance Measurement
• First test meter and leads by touching leads together.
Resistance should read a short circuit (very low resis-
tance)
• Circuit power must be turned OFF before testing resis-
tance
• Disconnect component from circuit before testing
• If meter is not auto ranging, set it to the correct range
(See multimeter’s operation manual)
• Use firm contact with meter leads
Continuity Measurement
• Some meters require a separate button press to enable
audible continuity testing
• Circuit power must be turned OFF before testing conti-
nuity
• Disconnect component from circuit before testing
• Use firm contact with meter leads
• First test meter and leads by touching leads together.
Meter should produce an audible alarm, indicating
continuity
Figure 7-2. Resistance Measurement
Figure 7-3. Continuity Measurement