SECTION 6 - JLG CONTROL SYSTEM
31215031
6-43
Test Notes
1.
Personality settings can be adjusted anywhere within
the adjustment range in order to achieve optimum
machine performance.
2.
Stop watch should be started with the function move-
ment, not with actuation of the joystick or switch.
3.
Drive speeds should be set to the values below regard-
less of the tire size.
4.
All speed tests are run from the platform, these speeds
do not reflect the ground control operation.
5.
The Platform Speed Control knob must be at full speed
(turned clockwise completely) unless noted.
6.
Some flow control functions may not work with the Plat-
form Speed Control knob clicked into the creep posi-
tion.
7.
Functional speeds may vary due to cold thick hydraulic
oil. Test should be run with the oil temperature above
38° C (100° F).
Table 6-6. Function Speeds (In Seconds)
Function
Speed
(Seconds)
Main Lift Up
26 - 32
Main Lift Down
26 - 32
Swing Right & Left
(No more than 10% difference between swing left
and swing right.)
79 - 101
Main Telescope In
22 - 30
Main Telescope Out
35 - 50
Platform Rotate Right & Left
(No more than 15% difference between rotate left
and rotate right.)
16 - 25
Articulating Jib Up
22 - 34
Articulating Jib Down
16 - 26
Tower Lift Up
37 - 50
Tower Lift Down
28 - 38
Lower Telescope Out
15 - 23
Lower Telescope In
09 - 15
Drive (2 - WD & 4 - WD) (Other Engines)
(Forward)
30 - 34 (4.25 MPH)
Drive (2 - WD & 4 - WD) (Deutz Engines)
(Forward)
34 - 38 (4.02 MPH)
Drive (2 - WD & 4 - WD) (Above Horizontal)
(Forward & Reverse)
46 - 54 (0.68 MPH)
1001245447-A
Go
to
Discount-Equipment.com
to
order
your
parts