SECTION 6 - LSS SETUP/CALIBRATION/SERVICE
6-2
31215079
6.3
DIAGNOSTIC MENU
NOTE:
If necessary refer to Section 5 - Analyzer Menu Flow
Charts.
The Diagnostic Load Menu is another troubleshooting
tool for the Load Sensing System. Sensor and status
information is presented in real-time for the technician.
To access the Diagnostic Menu, use the LEFT and RIGHT
Arrow keys to select DIAGNOSTICS from the Top Level
Menu. Press the ENTER key to select the menu.
NOTE:
The Diagnostic, Load menu is not available when the
LSS is not enabled. (Machine Setup, Load is set to
0=Not Installed
Press the LEFT and RIGHT Arrow keys to view the load
sub-menus and press the enter key. Once in the load
sub-menu, press the LEFT and RIGHT arrow keys to view
the various displays.
The table below details the structure of the Diagnostic,
Load Menu, and describes the meaning of each piece of
information presented.
6.4
PERSONALITIES
The following parameter in the PERSONALITIES, LOAD menu adjust performance of the LSS. All adjustments must be
made in Access Level 1 (33271).
Table 6-2. Diagnostic Menu Descriptions
DIAGNOSTICS MENU
(DISPLAYED ON ANALYZER 1ST LINE)
PARAMETER (DISPLAYED
ON ANALYZER 2ND LINE)
PARAMETER VALUE
(DISPLAYED ON
ANALYZER 2ND LINE)
DESCRIPTION
LOAD
:
PLTLOAD
+XXXX Kg
Displays (Total Measured Force – Empty Platform
Calibration), in kilograms
PLTGROS
+XXXX Kg
Displays Total Measured Force (Sum of Pins 1 thru 4
LOAD) in kilograms
OVERLOADED?
Yes / No
Displays Current LSS Module Overload Status
CELL 1
+XXXX Kg
Displays Calibrated Cell Reading in kilograms
CELL 2
+XXXX Kg
Displays Calibrated Cell Reading in kilograms
CELL 3
+XXXX Kg
Displays Calibrated Cell Reading in kilograms
CELL 4
+XXXX Kg
Displays Calibrated Cell Reading in kilograms
ANALYZER
VX.XXXX
Displays Analyzer Software Version
Table 6-3. Personalities
SUBMENU (DISPLAYED ON
ANALYZER1ST LINE)
PARAMETER (DISPLAYED ON
ANALYZER 2ND LINE)
DESCRIPTION
LOAD:
ACC’Y XXXX KG
Displays/adjusts a derating for
accessories.
OVR DBNCE 3 S
Displays/ adjusts the debounce
delay before an overload.
OVR HOLD 5 S
Displays/adjusts the minimum
delay before an overload can be
released.