SECTION 5 - JLG CONTROL SYSTEM
5-26
31215079
.
Table 5-4. Machine Model Personality
Adjustment
Adjustment
Adjustment Range
Model Default Values
330LRT
430LRT
DRIVE
Accel
0.1 - 5.0 (sec)
2.0
2.0
Decel
0.1 - 3.0 (sec)
2.0
2.0
Min Forward
500-800 mA
680
690
Hi Drv Fwd
1000-1800 mA
1500
1400
Mid Drv Fwd
1100-1500 mA
1400
1300
Low Drv Fwd
900-1100 mA
1000
950
Min Reverse
500-800 mA
650
690
Hi Drv Rev
1000-1800 mA
1500
1400
Mid Drv Rev
1100-1500 mA
1400
1300
Low Drv Rev
900-1100 mA
1000
950
Elev Fwd Max
700-1000 mA
860
850
Elev Rev Max
700-1000 mA
860
850
LIFT
Accel
0.1 - 5.0 (sec)
2.0
2.0
Decel
0.1 - 3.0 (sec)
1.0
1.0
Up Accel
0.1 - 5.0 (sec)
NA
NA
Up Decel
0.1 - 3.0 (sec)
NA
NA
Min Up
0 - 35%
19
19
Max Up
0 - 75%
55
55
Min Down
0 - 35%
19
19
Max Down
0 - 75%
45
45
LOAD
Overload 450-1220
kg
950
590
Accy
0-680 kg
0.0
0.0
Overload Dbnce
0.1 - 10.0 (sec)
3.0
3.0
Overload Hold
0.5 - 10 (sec)
5.0
5.0
JOYSTICK
Fwd Max
0.00 - 5.00V
1.1
1.1
Fwd Min
0.00 - 5.00V
2.25
2.25
Rev Min
0.00 - 5.00V
2.75
2.75
Rev Max
0.00 - 5.00V
3.9
3.9
TEMP CUTOUT
Cutout Set
-30 - 0 (C)
-27
-27
1001241349_B
NOTE:
These settings may be changed in order to achieve optimal performance.