SECTION 3 - CHASSIS & SCISSOR ARMS
3-16
3121788
3.8
GROUND CONTROL STATION
Components Location
NOTICE
DISCONNECT MAIN POWER FROM THE BATTERIES BEFORE ATTEMPT-
ING TO SERVICE THE ELECTRICAL SYSTEM. FAILURE TO DO SO COULD
CAUSE DAMAGE TO THE MACHINES ELECTRICAL COMPONENTS.
Removal
1.
Disconnect battery power from the machine.
2.
Lift the rear panel cover flap to gain access to the
mounting nuts on the control station bracket
mounting bolts.
3.
Remove two screws, washers and tinnerman
nuts attaching the ground control panel to the
frame.
4.
When panel is released, lift and remove protec-
tive rear cover and put aside.
5.
Rotate the ground control station and discon-
nect the desired connectors and remove compo-
nents on the back of the panel.
Installation
1.
Check that all components are installed into the
control station panel and connected to the wir-
ing harness on the back of the panel.
2.
Insert the control station into position on the
machine and align the mounting holes in the
panel with the mounting holes in the frame.
3.
Insert the rear panel cover (flap) between the
frame and the control station bracket. Align the
holes in the cover with the holes in the frame,
and control station bracket.
4.
Attach using two mounting screws, washers and
tinnerman nuts. Tighten securely the hardware.
5.
Reconnect the battery power to the machine,
start the machine and check machine operation.
1.
Ground/Platform/OFF Key Selector Switch
2.
Platform Lift/Lower Switch
3.
Inverter ON/OFF Switch (If Equipped)
4.
Ground Emergency Stop Button
5.
Hourmeter Gauge
6.
Overload Indicator
7.
MDI - Indicator (If Equipped)
000000.0
MAF10180
1
2
3
5
7
6
4
Go to
Discount-Equipment.com
to
order your
parts