SECTION 3 - CHASSIS & SCISSOR ARMS
3121788
3-11
3.4
DC/AC POWER INVERTER INSTALLATION - OPTION
Set the master power switch
(item 5)
on the side of the
inverter unit to ON and leave it there. Use the inverter on/
off switch at the Ground Control panel (see Ground Con-
trol Station - page 3-16, item 3) to power the inverter on
and off, via the DC power contactor relay (item 6 in illustra-
tion below).
DESCRIPTION
ALL MACHINES
Electrical System Voltage (DC)
24V
Power Inverter:
DC Input:
DC Input Voltage:
Operating Temperature:
AC Output:
Output Power (Continuous):
Output Power (Surge):
Output Power (AC):
Output Voltage (AC):
Output Frequency:
Type:
Protection:
Out put Reverse DC Polarity:
Power Bright
20 to 30 VDC
-4° F (-20° C) to 113° F (+45° C)
900W
1800W
7.5A
117V +/– 10%
60 Hz
Modified Sine Wave
3 X 25A Replaceable Fuse
Figure 3-7. DC/AC Power Inverter - Installation
1.
DC/AC Power Inverter
2.
DC Input Fuses (3 X 25 Amp Each)
3.
DC (+) Positive Input from Batteries
4.
DC (–) Negative Input from Batteries
5.
Inverter Master Power Switch (On Side Panel)
6.
DC Power Contactor Relay
7.
Contactor Relay Mounting Bracket and Hardware
8.
DC (+) Positive 80Amp Inline Fuse For Inverter Circuit Power Feed
9.
AC Power Output to Platform Receptacle Cable
10.
AC Line Filter