SECTION 3 - MACHINE CONTROLS, INDICATORS AND OPERATION
3-22
– JLG Lift –
3121272
3.11 DC TO AC INVERTER OPERATION (OPTION)
1.
The AC inverter ON/OFF
toggle switch (1)
is located
on the machines’
ground control panel (2)
.
2.
When the toggle switch is set to the ON position this
will allow AC current from the inverter to flow to the
inverter AC extension cable plug located at the right
rear of the machine.
The platform AC receptacle box extension cable plug,
also located at the rear of the machine can be plugged
into the inverter AC extension cable, or a device can
be plugged directly into the inverter AC cable at this
point.
NOTE:
Turn off any device before connecting to inverter AC cir-
cuit. Connect devices one at a time to the AC receptacle
box. Do not connect to many high-surge devices at once.
NOTICE
IF INVERTER SWITCH IS LEFT ON AND EMERGENCY STOP BUTTON IS NOT
PUSHED IN, POWER WILL DRAIN FROM THE BATTERIES.
3.
To turn off the AC current to the platform AC recepta-
cle box, set the inverter toggle switch to the OFF posi-
tion.
NOTE:
The inverter audible alarm may make a momentary chirp
when the inverter is turned OFF. This same alarm may also
sound when the inverter is being connected to or discon-
nected from the 24 volt battery bank.
NOTE:
Further General and Troubleshooting information about
the Inverter can be found in the Service Manual for this
machine.
Figure 3-13. Location of AC Inverter ON/OFF -
Toggle Switch
1.
Inverter ON/OFF Switch
2.
Ground Control Panel
INVERTER
ON
OFF
1001143010A
1
2