SECTION 4 - MACHINE OPERATION
4-14
3121170
DO NOT USE ASOV AS AN ALTERNATIVE TO SHUTTING DOWN MACHINE PROPERLY.
Fuel Reserve / Shut-Off System
NOTE:
Reference the Service and Maintenance Manual along with a
qualified JLG Mechanic to verify your machine setup.
The Fuel Shutoff System monitors the fuel in the tank and senses
when the fuel level is getting low. The JLG Control System auto-
matically shuts the engine down before the fuel tank is emptied
unless the machine is set up for Engine Restart.
If fuel level reaches the Low Fuel range the ¼ tank
indicator will flash once a second and there will be
approximately 5 minutes of engine run time left. If
the system is in this condition and automatically
shuts down the engine, or the engine is manually
shut down before the 5 minute run time is com-
plete, the ¼ tank indicator will flash 10 times a sec-
ond and the engine will reac t according to
machine setup. Setup options are as follows:
• Engine One Restart - When the engine shuts down, the
operator will be permitted to cycle power and restart the
engine once with approximately 2 minutes of run time.
After the 2 minute run time is complete or if the engine is
shut down by the operator prior to the completion of the 2
minute run time, it cannot be restarted until fuel is added
to the tank.